메뉴 건너뛰기




Volumn 10, Issue 5, 2006, Pages 269-282

Reduction of organ motion effects in IMRT and conformal 3D radiation delivery by using gating and tracking techniques

Author keywords

Radiotherapy; Respiratory gating; Respiratory movement

Indexed keywords

AIRFLOW; AMPLITUDE MODULATION; BREAST TUMOR; BREATH HOLDING; BREATHING; BREATHING MECHANICS; CANCER CENTER; CANCER PATIENT; CANCER RADIOTHERAPY; DEVICE; DOSIMETRY; EXPERIENCE; GEOMETRY; HEALTH CARE FACILITY; HEART DISEASE; HUMAN; IMAGING SYSTEM; INTENSITY MODULATED RADIATION THERAPY; IRRADIATION; LIVER CANCER; LUNG CANCER; LUNG DISEASE; MEASUREMENT; PATIENT POSITIONING; PATIENT SELECTION; POPULATION RESEARCH; PREDICTION; PRIORITY JOURNAL; RESPIRATION CONTROL; RISK REDUCTION; SAMPLE; SHORT SURVEY; SIMULATION; SIMULATOR; THREE DIMENSIONAL IMAGING; TREATMENT PLANNING; TUMOR LOCALIZATION; TUMOR VOLUME; X RAY; ARTIFACT; COMPUTER ASSISTED RADIOTHERAPY; GENERAL APPARATUS, EQUIPMENT AND SUPPLIES; INSTRUMENTATION; INTERVENTIONAL RADIOLOGY; METHODOLOGY; MOVEMENT (PHYSIOLOGY); RADIATION DOSE; REVIEW;

EID: 33749265478     PISSN: 12783218     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.canrad.2006.05.009     Document Type: Short Survey
Times cited : (98)

References (80)
  • 3
    • 23744457590 scopus 로고    scopus 로고
    • Residual motion of lung tumours in gated radiotherapy with external respiratory surrogates
    • Berbeco R.I., Nishioka S., Shirato H., Chen G.T.Y., and Jiang S.B. Residual motion of lung tumours in gated radiotherapy with external respiratory surrogates. Phys. Med. Biol. 50 (2005) 3655-3667
    • (2005) Phys. Med. Biol. , vol.50 , pp. 3655-3667
    • Berbeco, R.I.1    Nishioka, S.2    Shirato, H.3    Chen, G.T.Y.4    Jiang, S.B.5
  • 4
    • 25444516019 scopus 로고    scopus 로고
    • Towards fluoroscopic respiratory gating for lung tumours without radiopaque markers
    • Berbeco R.I., Mostafavi H., Sharp G., and Jiang S.B. Towards fluoroscopic respiratory gating for lung tumours without radiopaque markers. Phys. Med. Biol. 50 (2005) 4481-4490
    • (2005) Phys. Med. Biol. , vol.50 , pp. 4481-4490
    • Berbeco, R.I.1    Mostafavi, H.2    Sharp, G.3    Jiang, S.B.4
  • 5
    • 0942277196 scopus 로고    scopus 로고
    • Integrated radiotherapy imaging system (IRIS): Design considerations of tumour tracking with linac gantry-mounted diagnostic X-rays systems with flat-panel detectors
    • Berbeco R.I., Jiang S.B., Sharp G.C., Chen G.T., Mostafavi H., and Shirato H. Integrated radiotherapy imaging system (IRIS): Design considerations of tumour tracking with linac gantry-mounted diagnostic X-rays systems with flat-panel detectors. Phys. Med. Biol. 49 (2004) 243-255
    • (2004) Phys. Med. Biol. , vol.49 , pp. 243-255
    • Berbeco, R.I.1    Jiang, S.B.2    Sharp, G.C.3    Chen, G.T.4    Mostafavi, H.5    Shirato, H.6
  • 6
    • 0842327792 scopus 로고    scopus 로고
    • Effects of motion on the total dose distribution
    • Bortfeld T., Jiang S.B., and Rietzel E. Effects of motion on the total dose distribution. Semin. Rad. Onc. 14 (2004) 41-51
    • (2004) Semin. Rad. Onc. , vol.14 , pp. 41-51
    • Bortfeld, T.1    Jiang, S.B.2    Rietzel, E.3
  • 7
    • 18544404523 scopus 로고    scopus 로고
    • Definition of volumes in external radiotherapy: ICRU reports 50 and 62
    • Chavaudra J., and Bridier A. Definition of volumes in external radiotherapy: ICRU reports 50 and 62. Cancer Radiother. 5 (2001) 472-478
    • (2001) Cancer Radiother. , vol.5 , pp. 472-478
    • Chavaudra, J.1    Bridier, A.2
  • 8
    • 0842327786 scopus 로고    scopus 로고
    • Artifacts in computed tomography scanning of moving objects
    • Chen G.T., Kung J.H., and Beaudette K.P. Artifacts in computed tomography scanning of moving objects. Semin. Radiat. Oncol. 14 (2004) 19-26
    • (2004) Semin. Radiat. Oncol. , vol.14 , pp. 19-26
    • Chen, G.T.1    Kung, J.H.2    Beaudette, K.P.3
  • 9
    • 0034811943 scopus 로고    scopus 로고
    • Fluoroscopic study of tumour motion due to breathing: facilitating precise radiation therapy for lung cancer patients
    • Chen Q.S., Weinhous M.S., Deibel F.C., Ciezki J.P., and Macklis R.M. Fluoroscopic study of tumour motion due to breathing: facilitating precise radiation therapy for lung cancer patients. Med. Phys. 28 (2001) 1850-1856
    • (2001) Med. Phys. , vol.28 , pp. 1850-1856
    • Chen, Q.S.1    Weinhous, M.S.2    Deibel, F.C.3    Ciezki, J.P.4    Macklis, R.M.5
  • 10
    • 1942516486 scopus 로고    scopus 로고
    • Accounting for center-of-mass target motion using convolution methods in Monte Carlo-based dose calculations of the lung
    • Chetty I.J., Rosu M., McShan D.L., Fraass B.A., Balter J.M., and Ten Haken R.K. Accounting for center-of-mass target motion using convolution methods in Monte Carlo-based dose calculations of the lung. Med. Phys. 31 (2004) 925-932
    • (2004) Med. Phys. , vol.31 , pp. 925-932
    • Chetty, I.J.1    Rosu, M.2    McShan, D.L.3    Fraass, B.A.4    Balter, J.M.5    Ten Haken, R.K.6
  • 12
    • 20444401497 scopus 로고    scopus 로고
    • Comparison of end normal inspiration and expiration for gated intensity modulated radiation therapy (IMRT) of lung cancer
    • Della Biancia C., Yorke E., Chui C.S., Giraud P., Rosenzweig K., Amols H., et al. Comparison of end normal inspiration and expiration for gated intensity modulated radiation therapy (IMRT) of lung cancer. Radiother. Oncol. 75 (2005) 149-156
    • (2005) Radiother. Oncol. , vol.75 , pp. 149-156
    • Della Biancia, C.1    Yorke, E.2    Chui, C.S.3    Giraud, P.4    Rosenzweig, K.5    Amols, H.6
  • 13
    • 24044543599 scopus 로고    scopus 로고
    • Real-time intrafraction motion tracking using the treatment couch: a feasibility study
    • D'Souza W.D., Naqvi S.A., and Yu C.X. Real-time intrafraction motion tracking using the treatment couch: a feasibility study. Phys. Med. Biol. 50 (2005) 4021-4033
    • (2005) Phys. Med. Biol. , vol.50 , pp. 4021-4033
    • D'Souza, W.D.1    Naqvi, S.A.2    Yu, C.X.3
  • 15
    • 0036008666 scopus 로고    scopus 로고
    • Radiothérapie des cancers du poumon : le blocage en inspiration sous contrôle spirométrique
    • Garcia R., Oozer R., Le Thanh H., Chastel D., Doyen J.C., Chauvet B., et al. Radiothérapie des cancers du poumon : le blocage en inspiration sous contrôle spirométrique. Cancer Radiother. 6 (2002) 30-38
    • (2002) Cancer Radiother. , vol.6 , pp. 30-38
    • Garcia, R.1    Oozer, R.2    Le Thanh, H.3    Chastel, D.4    Doyen, J.C.5    Chauvet, B.6
  • 19
    • 0842327796 scopus 로고    scopus 로고
    • Organ and tumour motion: An overview
    • Goitein M. Organ and tumour motion: An overview. Semin. Radiat. Oncol. 14 (2004) 2-9
    • (2004) Semin. Radiat. Oncol. , vol.14 , pp. 2-9
    • Goitein, M.1
  • 20
    • 0032899184 scopus 로고    scopus 로고
    • Set-up reproducibility in radiation therapy for lung cancer: a comparison between T-bar and expanded foam immobilization devices
    • Halperin R., Roa W., Field M., Hanson J., and Murray B. Set-up reproducibility in radiation therapy for lung cancer: a comparison between T-bar and expanded foam immobilization devices. Int. J. Radiat. Oncol. Biol. Phys. 43 (1999) 211-216
    • (1999) Int. J. Radiat. Oncol. Biol. Phys. , vol.43 , pp. 211-216
    • Halperin, R.1    Roa, W.2    Field, M.3    Hanson, J.4    Murray, B.5
  • 21
    • 0032844267 scopus 로고    scopus 로고
    • Deep inspiration breath-hold technique for lung tumours: the potential value of target immobilization and reduced lung density in dose escalation
    • Hanley J., Debois M.M., Mah D., Mageras G.S., Raben A., Rosenzweig K., et al. Deep inspiration breath-hold technique for lung tumours: the potential value of target immobilization and reduced lung density in dose escalation. Int. J. Radiat. Oncol. Biol. Phys. 45 (1999) 603-611
    • (1999) Int. J. Radiat. Oncol. Biol. Phys. , vol.45 , pp. 603-611
    • Hanley, J.1    Debois, M.M.2    Mah, D.3    Mageras, G.S.4    Raben, A.5    Rosenzweig, K.6
  • 22
    • 33749237804 scopus 로고    scopus 로고
    • Jiang S, Bortfeld T, Trofimov A, Rietzel E, Sharp G, Choi N, et al. Synchronized Moving Aperture Radiation Therapy (SMART): Treatment Planning using 4D CT Data. in The 14th International Conference on the Use of Computers in Radiation Therapy. Seoul, Korea; 2004.
  • 23
    • 0025349284 scopus 로고
    • Measurement of pulmonary parenchymal attenuation: use of spirometric gating with quantitative CT
    • Kalender W.A., Rienmuller R., Seissler W., Behr J., Welke M., and Fichte H. Measurement of pulmonary parenchymal attenuation: use of spirometric gating with quantitative CT. Radiology 175 (1990) 265-268
    • (1990) Radiology , vol.175 , pp. 265-268
    • Kalender, W.A.1    Rienmuller, R.2    Seissler, W.3    Behr, J.4    Welke, M.5    Fichte, H.6
  • 25
    • 17844385102 scopus 로고    scopus 로고
    • Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking
    • Keall P.J., Joshi S., Vedam S.S., Siebers J.V., Kini V.R., and Mohan R. Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking. Med. Phys. 32 (2005) 942-951
    • (2005) Med. Phys. , vol.32 , pp. 942-951
    • Keall, P.J.1    Joshi, S.2    Vedam, S.S.3    Siebers, J.V.4    Kini, V.R.5    Mohan, R.6
  • 26
    • 0035168732 scopus 로고    scopus 로고
    • Held-breath self-gating technique for radiotherapy of non-small cell lung cancer: a feasibility study
    • Kim D.J., Murray B.R., Halperin R., and Roa W.H. Held-breath self-gating technique for radiotherapy of non-small cell lung cancer: a feasibility study. Int. J. Radiat. Oncol. Biol. Phys. 49 (2001) 43-49
    • (2001) Int. J. Radiat. Oncol. Biol. Phys. , vol.49 , pp. 43-49
    • Kim, D.J.1    Murray, B.R.2    Halperin, R.3    Roa, W.H.4
  • 28
    • 0030047783 scopus 로고    scopus 로고
    • Respiration gated radiotherapy treatment: a technical study
    • Kubo H.D., and Hill B.C. Respiration gated radiotherapy treatment: a technical study. Phys. Med. Biol. 41 (1996) 83-91
    • (1996) Phys. Med. Biol. , vol.41 , pp. 83-91
    • Kubo, H.D.1    Hill, B.C.2
  • 29
    • 0033849941 scopus 로고    scopus 로고
    • Compatibility of Varian 2100C gated operations with enhanced dynamic wedge and IMRT dose delivery
    • Kubo H.D., and Wang L. Compatibility of Varian 2100C gated operations with enhanced dynamic wedge and IMRT dose delivery. Med. Phys. 27 (2000) 1732-1738
    • (2000) Med. Phys. , vol.27 , pp. 1732-1738
    • Kubo, H.D.1    Wang, L.2
  • 30
    • 0036127077 scopus 로고    scopus 로고
    • Introduction of audio gating to further reduce organ motion in breathing synchronized radiotherapy
    • Kubo H.D., and Wang L. Introduction of audio gating to further reduce organ motion in breathing synchronized radiotherapy. Med. Phys. 29 (2002) 345-350
    • (2002) Med. Phys. , vol.29 , pp. 345-350
    • Kubo, H.D.1    Wang, L.2
  • 33
    • 0023132335 scopus 로고
    • Implementation of random positioning error in computerised radiation treatment planning systems as a result of fractionation
    • Leong J. Implementation of random positioning error in computerised radiation treatment planning systems as a result of fractionation. Phys. Med. Biol. 32 (1987) 327-334
    • (1987) Phys. Med. Biol. , vol.32 , pp. 327-334
    • Leong, J.1
  • 34
    • 10744222972 scopus 로고    scopus 로고
    • A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing
    • Low D.A., Nystrom M., Kalinin E., Pankh P., Dempsey J.F., Bradley J.D., et al. A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing. Med. Phys. 30 (2003) 1254-1268
    • (2003) Med. Phys. , vol.30 , pp. 1254-1268
    • Low, D.A.1    Nystrom, M.2    Kalinin, E.3    Pankh, P.4    Dempsey, J.F.5    Bradley, J.D.6
  • 35
    • 0034237198 scopus 로고    scopus 로고
    • Reduction of cardiac volume in left-breast treatment fields by respiratory maneuvers: a CT study
    • Lu H.M., Cash E., Chen M.H., Chin L., Manning W.J., Harris J., et al. Reduction of cardiac volume in left-breast treatment fields by respiratory maneuvers: a CT study. Int. J. Radiat. Oncol. Biol. Phys. 47 (2000) 895-904
    • (2000) Int. J. Radiat. Oncol. Biol. Phys. , vol.47 , pp. 895-904
    • Lu, H.M.1    Cash, E.2    Chen, M.H.3    Chin, L.4    Manning, W.J.5    Harris, J.6
  • 36
    • 85026339925 scopus 로고    scopus 로고
    • Fluroscopic evaluation of diaphragmatic motion reduction with a respiratory gated radiotherapy system
    • Mageras G., Yorke E., Rosenzweig K., Braban L., Keatley E., Ford E., et al. Fluroscopic evaluation of diaphragmatic motion reduction with a respiratory gated radiotherapy system. J. Appl. Clin. Med. Phys. 2 (2001) 191-200
    • (2001) J. Appl. Clin. Med. Phys. , vol.2 , pp. 191-200
    • Mageras, G.1    Yorke, E.2    Rosenzweig, K.3    Braban, L.4    Keatley, E.5    Ford, E.6
  • 37
    • 0842306297 scopus 로고    scopus 로고
    • Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatment
    • Mageras G.S., and Yorke E. Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatment. Semin. Radiat. Oncol. 14 (2004) 65-75
    • (2004) Semin. Radiat. Oncol. , vol.14 , pp. 65-75
    • Mageras, G.S.1    Yorke, E.2
  • 38
    • 33748944092 scopus 로고    scopus 로고
    • "4D" IMRT Delivery
    • Bortfeld T., et al. (Ed), Springer-Verlag, Heidelberg
    • Mageras G.S., Yorke E., and Jiang S.B. "4D" IMRT Delivery. In: Bortfeld T., et al. (Ed). Image-Guided IMRT (2005), Springer-Verlag, Heidelberg 269-288
    • (2005) Image-Guided IMRT , pp. 269-288
    • Mageras, G.S.1    Yorke, E.2    Jiang, S.B.3
  • 39
    • 0034128896 scopus 로고    scopus 로고
    • Evaluation of the validity of a convolution method for incorporating tumour movement and set-up variations into the radiotherapy treatment planning system
    • McCarter S.D., and Beckham W.A. Evaluation of the validity of a convolution method for incorporating tumour movement and set-up variations into the radiotherapy treatment planning system. Phys. Med. Biol. 45 (2000) 923-931
    • (2000) Phys. Med. Biol. , vol.45 , pp. 923-931
    • McCarter, S.D.1    Beckham, W.A.2
  • 43
    • 0842349454 scopus 로고    scopus 로고
    • Tracking moving organs in real time
    • Murphy M.J. Tracking moving organs in real time. Semin. Radiat. Oncol. 14 (2004) 91-100
    • (2004) Semin. Radiat. Oncol. , vol.14 , pp. 91-100
    • Murphy, M.J.1
  • 44
    • 0037423954 scopus 로고    scopus 로고
    • Synchronized moving aperture radiation therapy (SMART): average tumour trajectory for lung patients
    • Neicu T., Shirato H., Seppenwoolde Y., and Jiang S.B. Synchronized moving aperture radiation therapy (SMART): average tumour trajectory for lung patients. Phys. Med. Biol. 48 (2003) 587-598
    • (2003) Phys. Med. Biol. , vol.48 , pp. 587-598
    • Neicu, T.1    Shirato, H.2    Seppenwoolde, Y.3    Jiang, S.B.4
  • 46
    • 0036535315 scopus 로고    scopus 로고
    • Issues in respiratory motion compensation during external-beam radiotherapy
    • Ozhasoglu C., and Murphy M.J. Issues in respiratory motion compensation during external-beam radiotherapy. Int. J. Radiat. Oncol. Biol. Phys. 52 (2002) 1389-1399
    • (2002) Int. J. Radiat. Oncol. Biol. Phys. , vol.52 , pp. 1389-1399
    • Ozhasoglu, C.1    Murphy, M.J.2
  • 47
    • 12844267410 scopus 로고    scopus 로고
    • DMLC leaf-pair optimal control for mobile, deforming target
    • Papiez L., and Rangaraj D. DMLC leaf-pair optimal control for mobile, deforming target. Med. Phys. 32 (2005) 275-285
    • (2005) Med. Phys. , vol.32 , pp. 275-285
    • Papiez, L.1    Rangaraj, D.2
  • 48
    • 25644438567 scopus 로고    scopus 로고
    • Real-time DMLC IMRT delivery for mobile and deforming targets
    • Papiez L., Rangaraj D., and Keall P. Real-time DMLC IMRT delivery for mobile and deforming targets. Med. Phys. 32 (2005) 3037-3048
    • (2005) Med. Phys. , vol.32 , pp. 3037-3048
    • Papiez, L.1    Rangaraj, D.2    Keall, P.3
  • 49
    • 0038530967 scopus 로고    scopus 로고
    • The leaf sweep algorithm for an immobile and moving target as an optimal control problem in radiotherapy delivery
    • Papiez L. The leaf sweep algorithm for an immobile and moving target as an optimal control problem in radiotherapy delivery. Math. Comput. Model. 37 (2003) 735-745
    • (2003) Math. Comput. Model. , vol.37 , pp. 735-745
    • Papiez, L.1
  • 51
    • 0027515971 scopus 로고
    • Lung volumes and forced ventilatory flows. Report Working Party Standardization of Lung Function Tests, European Community for Steel and Coal. Official Statement of the European Respiratory Society
    • Quanjer P.H., Tammeling G.J., Cotes J.E., Pedersen O.F., Peslin R., Yernault J.C., et al. Lung volumes and forced ventilatory flows. Report Working Party Standardization of Lung Function Tests, European Community for Steel and Coal. Official Statement of the European Respiratory Society. Eur. Respir. J. 16 (1993) 5-40
    • (1993) Eur. Respir. J. , vol.16 , pp. 5-40
    • Quanjer, P.H.1    Tammeling, G.J.2    Cotes, J.E.3    Pedersen, O.F.4    Peslin, R.5    Yernault, J.C.6
  • 53
    • 21144443433 scopus 로고    scopus 로고
    • Synchronized delivery of DMLC intensity modulated radiation therapy for stationary and moving targets
    • Rangaraj D., and Papiez L. Synchronized delivery of DMLC intensity modulated radiation therapy for stationary and moving targets. Med. Phys. 32 (2005) 1802-1817
    • (2005) Med. Phys. , vol.32 , pp. 1802-1817
    • Rangaraj, D.1    Papiez, L.2
  • 54
    • 0037606000 scopus 로고    scopus 로고
    • Initial clinical experience with moderate deep-inspiration breath hold using an active breathing control device in the treatment of patients with left-sided breast cancer using external beam radiation therapy
    • Remouchamps V.M., Letts N., Vicini F.A., Sharpe M.B., Kestin L.L., Chen P.Y., et al. Initial clinical experience with moderate deep-inspiration breath hold using an active breathing control device in the treatment of patients with left-sided breast cancer using external beam radiation therapy. Int. J. Radiat. Oncol. Biol. Phys. 56 (2003) 704-715
    • (2003) Int. J. Radiat. Oncol. Biol. Phys. , vol.56 , pp. 704-715
    • Remouchamps, V.M.1    Letts, N.2    Vicini, F.A.3    Sharpe, M.B.4    Kestin, L.L.5    Chen, P.Y.6
  • 55
    • 0037296146 scopus 로고    scopus 로고
    • Significant reductions in heart and lung doses using deep inspiration breath hold with active breathing control and intensity-modulated radiation therapy for patients treated with locoregional breast irradiation
    • Remouchamps V.M., Vicini F.A., Sharpe M.B., Kestin L.L., Martinez A.A., and Wong J.W. Significant reductions in heart and lung doses using deep inspiration breath hold with active breathing control and intensity-modulated radiation therapy for patients treated with locoregional breast irradiation. Int. J. Radiat. Oncol. Biol. Phys. 55 (2003) 392-406
    • (2003) Int. J. Radiat. Oncol. Biol. Phys. , vol.55 , pp. 392-406
    • Remouchamps, V.M.1    Vicini, F.A.2    Sharpe, M.B.3    Kestin, L.L.4    Martinez, A.A.5    Wong, J.W.6
  • 58
    • 0033799790 scopus 로고    scopus 로고
    • A novel tracking technique for the continuous precise measurement of tumour positions in conformal radiotherapy
    • Seiler P.G., Blattmann H., Kirsch S., Muench R.K., and Schilling C. A novel tracking technique for the continuous precise measurement of tumour positions in conformal radiotherapy. Phys. Med. Biol. 45 (2000) 103-110
    • (2000) Phys. Med. Biol. , vol.45 , pp. 103-110
    • Seiler, P.G.1    Blattmann, H.2    Kirsch, S.3    Muench, R.K.4    Schilling, C.5
  • 60
    • 1142299677 scopus 로고    scopus 로고
    • Prediction of respiratory tumour motion for real-time image-guided radiotherapy
    • Sharp G.C., Jiang S.B., Shimizu S., and Shirato H. Prediction of respiratory tumour motion for real-time image-guided radiotherapy. Phys. Med. Biol. 49 (2004) 425-440
    • (2004) Phys. Med. Biol. , vol.49 , pp. 425-440
    • Sharp, G.C.1    Jiang, S.B.2    Shimizu, S.3    Shirato, H.4
  • 61
    • 11044223588 scopus 로고    scopus 로고
    • Tracking errors in a prototype real-time tumour tracking system
    • Sharp G.C., Jiang S.B., Shimizu S., and Shirato H. Tracking errors in a prototype real-time tumour tracking system. Phys. Med. Biol. 49 (2004) 5347-5356
    • (2004) Phys. Med. Biol. , vol.49 , pp. 5347-5356
    • Sharp, G.C.1    Jiang, S.B.2    Shimizu, S.3    Shirato, H.4
  • 62
    • 0347625747 scopus 로고    scopus 로고
    • Validation of target volume and position in respiratory gated CT planning and treatment
    • Shen S., Duan J., Fiveash J.B., Brezovich I.A., Plant B.A., Spencer S.A., et al. Validation of target volume and position in respiratory gated CT planning and treatment. Med. Phys. 30 (2003) 3196-3205
    • (2003) Med. Phys. , vol.30 , pp. 3196-3205
    • Shen, S.1    Duan, J.2    Fiveash, J.B.3    Brezovich, I.A.4    Plant, B.A.5    Spencer, S.A.6
  • 66
    • 24944455908 scopus 로고    scopus 로고
    • Lung volume assessment for a cross-comparison of two breathing adapted techniques in radiotherapy
    • Simon L., Giraud P., Servois V., and Rosenwald J.C. Lung volume assessment for a cross-comparison of two breathing adapted techniques in radiotherapy. Int. J. Radiat. Oncol. Biol. Phys. 63 (2005) 602-609
    • (2005) Int. J. Radiat. Oncol. Biol. Phys. , vol.63 , pp. 602-609
    • Simon, L.1    Giraud, P.2    Servois, V.3    Rosenwald, J.C.4
  • 67
    • 0035164113 scopus 로고    scopus 로고
    • Deep inspiration breath hold to reduce irradiated heart volume in breast cancer patients
    • Sixel K.E., Aznar M.C., and Ung Y.C. Deep inspiration breath hold to reduce irradiated heart volume in breast cancer patients. Int. J. Radiat. Oncol. Biol. Phys. 49 (2001) 199-204
    • (2001) Int. J. Radiat. Oncol. Biol. Phys. , vol.49 , pp. 199-204
    • Sixel, K.E.1    Aznar, M.C.2    Ung, Y.C.3
  • 68
    • 1942452264 scopus 로고    scopus 로고
    • Aperture maneuver with compelled breath (AMC) for moving tumours: a feasibility study with a moving phantom
    • Suh Y., Yi B., Ahn S., Kim J., Lee S., Shin S., et al. Aperture maneuver with compelled breath (AMC) for moving tumours: a feasibility study with a moving phantom. Med. Phys. 31 (2004) 760-766
    • (2004) Med. Phys. , vol.31 , pp. 760-766
    • Suh, Y.1    Yi, B.2    Ahn, S.3    Kim, J.4    Lee, S.5    Shin, S.6
  • 69
    • 0031812176 scopus 로고    scopus 로고
    • Lung cancer: intermittent irradiation synchronized with respiratory motion-results of a pilot study
    • Tada T., Minakuchi K., Fujioka T., Sakurai M., Koda M., Kawase I., et al. Lung cancer: intermittent irradiation synchronized with respiratory motion-results of a pilot study. Radiology 207 (1998) 779-783
    • (1998) Radiology , vol.207 , pp. 779-783
    • Tada, T.1    Minakuchi, K.2    Fujioka, T.3    Sakurai, M.4    Koda, M.5    Kawase, I.6
  • 70
    • 15744405196 scopus 로고    scopus 로고
    • Development of a new linear accelerator mounted with dual X-ray fluoroscopy using amorphous silicon flat panel X-ray sensors to detect a gold seed in a tumour at real treatment position
    • Takai Y., Mitsuya M., Nemoto K., Ogawa Y., Matsusita H., Yamada S., et al. Development of a new linear accelerator mounted with dual X-ray fluoroscopy using amorphous silicon flat panel X-ray sensors to detect a gold seed in a tumour at real treatment position. Int. J. Radiat. Oncol. Biol. Phys. 51 (2001) 381
    • (2001) Int. J. Radiat. Oncol. Biol. Phys. , vol.51 , pp. 381
    • Takai, Y.1    Mitsuya, M.2    Nemoto, K.3    Ogawa, Y.4    Matsusita, H.5    Yamada, S.6
  • 71
    • 0037391655 scopus 로고    scopus 로고
    • Quantifying the predictability of diaphragm motion during respiration with a non-invasive external marker
    • Vedam S.S., Kini V.R., Keall P.J., Ramakrishnan V., Mostafavi H., and Mohan R. Quantifying the predictability of diaphragm motion during respiration with a non-invasive external marker. Med. Phys. 30 (2003) 505-513
    • (2003) Med. Phys. , vol.30 , pp. 505-513
    • Vedam, S.S.1    Kini, V.R.2    Keall, P.J.3    Ramakrishnan, V.4    Mostafavi, H.5    Mohan, R.6
  • 74
    • 0023617112 scopus 로고
    • The effect of the respiratory cycle on mediastinal and lung dimensions in Hodgkin's disease. Implications for radiotherapy gated to respiration
    • Willett C.G., Linggood R.M., Stracher M.A., Goitein M., Doppke K., Kushner D.C., et al. The effect of the respiratory cycle on mediastinal and lung dimensions in Hodgkin's disease. Implications for radiotherapy gated to respiration. Cancer 60 (1987) 1232-1237
    • (1987) Cancer , vol.60 , pp. 1232-1237
    • Willett, C.G.1    Linggood, R.M.2    Stracher, M.A.3    Goitein, M.4    Doppke, K.5    Kushner, D.C.6
  • 76
    • 85024950633 scopus 로고    scopus 로고
    • Interfractional anatomic variation in patients treated with respiration-gated radiotherapy
    • Yorke E., Rosenzweig K.E., Wagman R., and Mageras G.S. Interfractional anatomic variation in patients treated with respiration-gated radiotherapy. J. Appl. Clin. Med. Phys. 6 (2005) 19-32
    • (2005) J. Appl. Clin. Med. Phys. , vol.6 , pp. 19-32
    • Yorke, E.1    Rosenzweig, K.E.2    Wagman, R.3    Mageras, G.S.4
  • 77
    • 33749250687 scopus 로고    scopus 로고
    • Yorke E, Mageras G, LoSasso T, Mostafavi H, Ling C. Respiratory gating of sliding window IMRT. In: Proceedings of the World Congress on Medical Physics and Biomedical Engineering, Chicago; 2000. p. 4.
  • 79
    • 0029113269 scopus 로고
    • Intensity-modulated arc therapy with dynamic multileaf collimation: an alternative to tomotherapy
    • Yu C.X. Intensity-modulated arc therapy with dynamic multileaf collimation: an alternative to tomotherapy. Phys. Med. Biol. 40 (1995) 1435-1449
    • (1995) Phys. Med. Biol. , vol.40 , pp. 1435-1449
    • Yu, C.X.1
  • 80
    • 0346364988 scopus 로고    scopus 로고
    • Application of the spirometer in respiratory gated radiotherapy
    • Zhang T., Keller H., O'Brien M.J., Mackie T.R., and Paliwal B. Application of the spirometer in respiratory gated radiotherapy. Med. Phys. 30 (2003) 3165-3171
    • (2003) Med. Phys. , vol.30 , pp. 3165-3171
    • Zhang, T.1    Keller, H.2    O'Brien, M.J.3    Mackie, T.R.4    Paliwal, B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.