메뉴 건너뛰기




Volumn 24, Issue 8, 2006, Pages 1077-1085

Experimental and computational analyses of the effects of slice distortion from a metallic sphere in an MRI phantom

Author keywords

Magnetic susceptibilities; Metal artifact; MRI; Slice distortion; View angle tilting

Indexed keywords

AGAROSE; STAINLESS STEEL;

EID: 33748752031     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mri.2006.04.019     Document Type: Article
Times cited : (21)

References (27)
  • 1
    • 0030013529 scopus 로고    scopus 로고
    • The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds
    • Schenck J.F. The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds. Med Phys 23 (1996) 815-850
    • (1996) Med Phys , vol.23 , pp. 815-850
    • Schenck, J.F.1
  • 2
    • 0000546825 scopus 로고    scopus 로고
    • Artifacts in magnetic resonance imaging from metals
    • Bennett L.H., Wang P.S., and Donahue M.J. Artifacts in magnetic resonance imaging from metals. J Appl Phys 79 8 (1996) 4712-4714
    • (1996) J Appl Phys , vol.79 , Issue.8 , pp. 4712-4714
    • Bennett, L.H.1    Wang, P.S.2    Donahue, M.J.3
  • 3
    • 0000237958 scopus 로고
    • Calculation of the susceptibility-induced magnetic field from 3D NMR images with applications to trabecular bone
    • Hwang S., and Wehrli F. Calculation of the susceptibility-induced magnetic field from 3D NMR images with applications to trabecular bone. J Magn Res 109 (1995) 126-145
    • (1995) J Magn Res , vol.109 , pp. 126-145
    • Hwang, S.1    Wehrli, F.2
  • 7
    • 0026536844 scopus 로고
    • Titanium hip implants for improved magnetic resonance and computed tomography examinations
    • Ebraheim N.A., Savolaine E.R., Zeiss J., and Jackson W.T. Titanium hip implants for improved magnetic resonance and computed tomography examinations. Clin Orthop Relat Res 275 (1992) 194-198
    • (1992) Clin Orthop Relat Res , vol.275 , pp. 194-198
    • Ebraheim, N.A.1    Savolaine, E.R.2    Zeiss, J.3    Jackson, W.T.4
  • 8
    • 0036088094 scopus 로고    scopus 로고
    • MRI susceptibility artefacts related to scaphoid screws: the effect of screw type, screw orientation and imaging parameters
    • Ganapathi M., Joseph G., Savage R., Jones A.R., Timms B., and Lyons K. MRI susceptibility artefacts related to scaphoid screws: the effect of screw type, screw orientation and imaging parameters. J Hand Surg (British and European Volume) 27B 2 (2002) 165-170
    • (2002) J Hand Surg (British and European Volume) , vol.27 B , Issue.2 , pp. 165-170
    • Ganapathi, M.1    Joseph, G.2    Savage, R.3    Jones, A.R.4    Timms, B.5    Lyons, K.6
  • 10
    • 0023814837 scopus 로고
    • High-field strength MR imaging and metallic biomedical implants: an ex vivo evaluations of deflection forces
    • Shellock F.G., and Crues J.V. High-field strength MR imaging and metallic biomedical implants: an ex vivo evaluations of deflection forces. AJR Am J Roentgenol 151 (1988) 389-392
    • (1988) AJR Am J Roentgenol , vol.151 , pp. 389-392
    • Shellock, F.G.1    Crues, J.V.2
  • 11
    • 0031771124 scopus 로고    scopus 로고
    • Minimizing artifacts caused by metallic implants at MR imaging: experimental and clinical studies
    • Suh J.-S., Jeong E.-K., Shin K.-H., Cho J.H., Na J.-B., Kim D.-H., et al. Minimizing artifacts caused by metallic implants at MR imaging: experimental and clinical studies. AJR Am J Roentgenol 171 (1998) 1207-1213
    • (1998) AJR Am J Roentgenol , vol.171 , pp. 1207-1213
    • Suh, J.-S.1    Jeong, E.-K.2    Shin, K.-H.3    Cho, J.H.4    Na, J.-B.5    Kim, D.-H.6
  • 13
    • 0029184004 scopus 로고
    • Nonsusceptibility artifacts due to metallic objects in MR imaging
    • Camacho C.R., Plewes D.B., and Henkelman R.M. Nonsusceptibility artifacts due to metallic objects in MR imaging. J Magn Reson Imaging 5 (1995) 75-88
    • (1995) J Magn Reson Imaging , vol.5 , pp. 75-88
    • Camacho, C.R.1    Plewes, D.B.2    Henkelman, R.M.3
  • 14
    • 4344614596 scopus 로고    scopus 로고
    • Quantitative evaluation of metal artifact reduction techniques
    • Kolind S.H., Mackay A., Munk P.L., and Xiang Q.S. Quantitative evaluation of metal artifact reduction techniques. J Magn Reson Imaging 20 (2004) 487-495
    • (2004) J Magn Reson Imaging , vol.20 , pp. 487-495
    • Kolind, S.H.1    Mackay, A.2    Munk, P.L.3    Xiang, Q.S.4
  • 15
    • 0030012255 scopus 로고    scopus 로고
    • Optimization of parameters for MR evaluation of the spine with titanium pedicle screws
    • Petersilge C.A., Lewin J.S., Duerk J.L., Yoo J.U., and Ghaneyem A.J. Optimization of parameters for MR evaluation of the spine with titanium pedicle screws. AJR Am J Roentgenol 166 (1996) 1213-1218
    • (1996) AJR Am J Roentgenol , vol.166 , pp. 1213-1218
    • Petersilge, C.A.1    Lewin, J.S.2    Duerk, J.L.3    Yoo, J.U.4    Ghaneyem, A.J.5
  • 16
    • 0023765495 scopus 로고
    • MR imaging of metallic implants and materials: a complication of the literature
    • Shellock F.G. MR imaging of metallic implants and materials: a complication of the literature. AJR Am J Roentgenol 151 (1988) 811-814
    • (1988) AJR Am J Roentgenol , vol.151 , pp. 811-814
    • Shellock, F.G.1
  • 18
    • 7544240906 scopus 로고    scopus 로고
    • MRI if hip prosthesis using single-point methods: in vitro studies towards the artifact-free imaging of individuals with metal implants
    • Ramos-Cabrer P., Duynhoven J.P.M., Toorn A.V.D., and Nicolay K. MRI if hip prosthesis using single-point methods: in vitro studies towards the artifact-free imaging of individuals with metal implants. Magn Reson Imaging 22 (2004) 1097-1103
    • (2004) Magn Reson Imaging , vol.22 , pp. 1097-1103
    • Ramos-Cabrer, P.1    Duynhoven, J.P.M.2    Toorn, A.V.D.3    Nicolay, K.4
  • 19
    • 0023883943 scopus 로고
    • Total inhomogeneity correction including chemical shifts and susceptibility by view angle tilting
    • Cho Z.H., Kim D.J., and Kim Y.K. Total inhomogeneity correction including chemical shifts and susceptibility by view angle tilting. Med Phys 15 (1988) 7-11
    • (1988) Med Phys , vol.15 , pp. 7-11
    • Cho, Z.H.1    Kim, D.J.2    Kim, Y.K.3
  • 21
    • 0034057081 scopus 로고    scopus 로고
    • The use of view angle tilting to reduce distortions in magnetic resonance imaging of cryosurgery
    • Daniel B.L., and Butts K. The use of view angle tilting to reduce distortions in magnetic resonance imaging of cryosurgery. J Magn Reson 18 (2000) 281-286
    • (2000) J Magn Reson , vol.18 , pp. 281-286
    • Daniel, B.L.1    Butts, K.2
  • 22
    • 12844254477 scopus 로고    scopus 로고
    • Reduction of blurring in view angle tilting MRI
    • Butts K., Pauly J.M., and Gold G.E. Reduction of blurring in view angle tilting MRI. Magn Reson Med 53 (2005) 418-424
    • (2005) Magn Reson Med , vol.53 , pp. 418-424
    • Butts, K.1    Pauly, J.M.2    Gold, G.E.3
  • 23
    • 0001595939 scopus 로고
    • Susceptibility-limited resolution in nuclear magnetic resonance microscopy
    • Callaghan P.T. Susceptibility-limited resolution in nuclear magnetic resonance microscopy. J Magn Reson 87 (1990) 304-318
    • (1990) J Magn Reson , vol.87 , pp. 304-318
    • Callaghan, P.T.1
  • 24
    • 0036210548 scopus 로고    scopus 로고
    • Technical considerations: CT and MR imaging in the postoperative orthopedic patient
    • White L.M., and Buckwalter K.A. Technical considerations: CT and MR imaging in the postoperative orthopedic patient. Semin Musculoskelet Radiol 6 1 (2002) 5-17
    • (2002) Semin Musculoskelet Radiol , vol.6 , Issue.1 , pp. 5-17
    • White, L.M.1    Buckwalter, K.A.2
  • 25
    • 0028342581 scopus 로고
    • Simulation of susceptibility artifacts in 2D and 3D Fourier transform spin-echo and gradient-echo magnetic resonance imaging
    • Bakker C.J.G., Bhagwandien R., Moerland M.A., and Ramos L.M.P. Simulation of susceptibility artifacts in 2D and 3D Fourier transform spin-echo and gradient-echo magnetic resonance imaging. Magn Reson Imaging 12 5 (1994) 767-774
    • (1994) Magn Reson Imaging , vol.12 , Issue.5 , pp. 767-774
    • Bakker, C.J.G.1    Bhagwandien, R.2    Moerland, M.A.3    Ramos, L.M.P.4
  • 26
    • 0027379107 scopus 로고
    • MR procedures and biomedical implants, materials, and devices: 1993 updates
    • Shellock F.G., Morisoli S., and Kanal E. MR procedures and biomedical implants, materials, and devices: 1993 updates. Radiology 189 (1993) 587-599
    • (1993) Radiology , vol.189 , pp. 587-599
    • Shellock, F.G.1    Morisoli, S.2    Kanal, E.3
  • 27
    • 0030208180 scopus 로고    scopus 로고
    • Magnetic resonance imaging for the determination of magnetic susceptibility of materials
    • Beuf O., Briguet A., Lissac M., and Davis R. Magnetic resonance imaging for the determination of magnetic susceptibility of materials. J Magn Reson B 112 (1996) 111-118
    • (1996) J Magn Reson B , vol.112 , pp. 111-118
    • Beuf, O.1    Briguet, A.2    Lissac, M.3    Davis, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.