메뉴 건너뛰기




Volumn 47, Issue 8, 2006, Pages 3381-3389

Identifying glaucomatous vision loss with visual-function-specific perimetry in the diagnostic innovations in glaucoma study

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; AREA UNDER THE CURVE; ARTICLE; AUTOANALYZER; CONTROLLED STUDY; DIAGNOSTIC TEST; DIAGNOSTIC VALUE; FREQUENCY DOUBLING TECHNOLOGY PERIMETRY; GLAUCOMA; HIGH PASS RESOLUTION PERIMETRY; HUMAN; HUMAN CELL; HUMAN TISSUE; INTERMETHOD COMPARISON; INTRAOCULAR HYPERTENSION; MAJOR CLINICAL STUDY; OPTIC NERVE DISEASE; PERIMETRY; PRIORITY JOURNAL; RECEIVER OPERATING CHARACTERISTIC; RETINA INJURY; SENSITIVITY AND SPECIFICITY; SHORT WAVELENGTH AUTOMATED PERIMETRY; STANDARD AUTOMATED PERIMETRY; VISUAL FIELD; VISUAL FUNCTION SPECIFIC PERIMETRY; VISUAL IMPAIRMENT; COMPARATIVE STUDY; FEMALE; LABORATORY DIAGNOSIS; MALE; METHODOLOGY; MIDDLE AGED; PREDICTION AND FORECASTING; ROC CURVE; VISUAL DISORDER;

EID: 33748121628     PISSN: 01460404     EISSN: None     Source Type: Journal    
DOI: 10.1167/iovs.05-1546     Document Type: Article
Times cited : (89)

References (40)
  • 2
    • 0028307409 scopus 로고
    • Selective versus non-selective losses in glaucoma
    • Johnson CA. Selective versus non-selective losses in glaucoma. J Glaucoma. 1994;3:S32-S44.
    • (1994) J Glaucoma , vol.3
    • Johnson, C.A.1
  • 3
    • 0028304945 scopus 로고
    • Evidence for a variety of functional defects in glaucoma suspect eyes
    • Sample PA, Madrid M, Weinreb RN. Evidence for a variety of functional defects in glaucoma suspect eyes. J Glaucoma. 1994;3:S5-S18.
    • (1994) J Glaucoma , vol.3
    • Sample, P.A.1    Madrid, M.2    Weinreb, R.N.3
  • 4
    • 0027688673 scopus 로고
    • Morphology of a small-field bistratified ganglion cell type in the macaque and human retina
    • Dacey DM. Morphology of a small-field bistratified ganglion cell type in the macaque and human retina. Vis Neurosci. 1993;10:1081-1098.
    • (1993) Vis Neurosci , vol.10 , pp. 1081-1098
    • Dacey, D.M.1
  • 5
    • 0028117203 scopus 로고
    • The 'blue-on' opponent pathway in primate retina originates from a distinct bistratified ganglion cell type
    • Dacey DM, Lee BB. The 'blue-on' opponent pathway in primate retina originates from a distinct bistratified ganglion cell type. Nature. 1994;367:731-735.
    • (1994) Nature , vol.367 , pp. 731-735
    • Dacey, D.M.1    Lee, B.B.2
  • 6
    • 0041878358 scopus 로고    scopus 로고
    • Colour coding in the primate retina: Diverse cell types and cone-specific circuitry
    • Dacey DM, Packer OS. Colour coding in the primate retina: diverse cell types and cone-specific circuitry. Curr Opin Neurobiol. 2003;13:421-427.
    • (2003) Curr Opin Neurobiol , vol.13 , pp. 421-427
    • Dacey, D.M.1    Packer, O.S.2
  • 8
    • 0026795849 scopus 로고
    • Performance of nonlinear visual units in ocular hypertension and glaucoma
    • Maddess T, Henry GH. Performance of nonlinear visual units in ocular hypertension and glaucoma. Clin Vis Sci. 1992;7:371-383.
    • (1992) Clin Vis Sci , vol.7 , pp. 371-383
    • Maddess, T.1    Henry, G.H.2
  • 10
    • 0002003191 scopus 로고
    • Peripheral displacement thresholds in glaucoma and ocular hypertension
    • Heijl A, ed, Amsterdam: Kugler;
    • Fitzke FW, Poinoosawmy D, Nagasubramanian S, Hitchings RA. Peripheral displacement thresholds in glaucoma and ocular hypertension. In: Heijl A, ed. Perimetry Update 1988/89. Amsterdam: Kugler; 1989:399-405.
    • (1989) Perimetry Update 1988/89 , pp. 399-405
    • Fitzke, F.W.1    Poinoosawmy, D.2    Nagasubramanian, S.3    Hitchings, R.A.4
  • 11
    • 0029075683 scopus 로고
    • Motion perception deficits in glaucomatous optic neuropathy
    • Trick GL, Steinman BS, Amyot M. Motion perception deficits in glaucomatous optic neuropathy. Vision Res. 1995;25:2225-2233.
    • (1995) Vision Res , vol.25 , pp. 2225-2233
    • Trick, G.L.1    Steinman, B.S.2    Amyot, M.3
  • 12
    • 0031013055 scopus 로고    scopus 로고
    • Motion perimetry identifies nerve fiber bundle-like defects in ocular hypertension
    • Wall M, Jennisch CS, Munden PM. Motion perimetry identifies nerve fiber bundle-like defects in ocular hypertension. Arch Ophthalmol. 1997;115:26-33.
    • (1997) Arch Ophthalmol , vol.115 , pp. 26-33
    • Wall, M.1    Jennisch, C.S.2    Munden, P.M.3
  • 13
    • 0030754542 scopus 로고    scopus 로고
    • Perimetric motion thresholds are elevated in glaucoma suspects and glaucoma patients
    • Bosworth CF, Sample PA, Weinreb RN. Perimetric motion thresholds are elevated in glaucoma suspects and glaucoma patients. Vision Res. 1997;37:1989-1997.
    • (1997) Vision Res , vol.37 , pp. 1989-1997
    • Bosworth, C.F.1    Sample, P.A.2    Weinreb, R.N.3
  • 15
    • 0026738847 scopus 로고
    • High-pass resolution perimetry: Evidence for parvocellular neural channel dependence
    • Frisen L. High-pass resolution perimetry: evidence for parvocellular neural channel dependence. Neuro-ophthalmology. 1992;4:257-264.
    • (1992) Neuro-ophthalmology , vol.4 , pp. 257-264
    • Frisen, L.1
  • 16
    • 0028848043 scopus 로고
    • High-pass resolution perimetry: Central-field neuroretinal correlates
    • Frisen L. High-pass resolution perimetry: central-field neuroretinal correlates. Vis Res. 1995;35:293-301.
    • (1995) Vis Res , vol.35 , pp. 293-301
    • Frisen, L.1
  • 17
    • 22144443818 scopus 로고    scopus 로고
    • Structure and function of parallel pathways in the primate early visual system
    • Callaway EM. Structure and function of parallel pathways in the primate early visual system. J Physiol. 2005;566:13-19.
    • (2005) J Physiol , vol.566 , pp. 13-19
    • Callaway, E.M.1
  • 18
    • 30344488859 scopus 로고    scopus 로고
    • The M, P, K pathways of the primate visual system
    • Chalupa LM, Werner JS, eds, Cambridge, MA: The MIT Press;
    • Kaplan E. The M, P, K pathways of the primate visual system. In: Chalupa LM, Werner JS, eds. The Visual Neurosciences. Cambridge, MA: The MIT Press; 2004:481-493.
    • (2004) The Visual Neurosciences , pp. 481-493
    • Kaplan, E.1
  • 19
    • 0347339173 scopus 로고    scopus 로고
    • Merging processing streams: Color cues for motion detection and interpretation
    • Chalupa LM, Werner JS, eds, Cambridge, MA: The MIT Press;
    • Dobkins KR, Albright TD. Merging processing streams: color cues for motion detection and interpretation. In: Chalupa LM, Werner JS, eds. The Visual Neurosciences. Cambridge, MA: The MIT Press; 2004:1217-1228.
    • (2004) The Visual Neurosciences , pp. 1217-1228
    • Dobkins, K.R.1    Albright, T.D.2
  • 21
    • 0034070873 scopus 로고    scopus 로고
    • The value of high-pass resolution perimetry in glaucoma
    • Chauhan BC. The value of high-pass resolution perimetry in glaucoma. Curr Opin Ophthalmol. 2000;11:85-89.
    • (2000) Curr Opin Ophthalmol , vol.11 , pp. 85-89
    • Chauhan, B.C.1
  • 23
    • 0033993512 scopus 로고    scopus 로고
    • Short-wavelength automated perimetry: Its role in the clinic and for understanding ganglion cell function
    • Sample PA. Short-wavelength automated perimetry: its role in the clinic and for understanding ganglion cell function. Prog Retin Eye Res. 2000;19:369-383.
    • (2000) Prog Retin Eye Res , vol.19 , pp. 369-383
    • Sample, P.A.1
  • 24
    • 0034124759 scopus 로고    scopus 로고
    • Visual function-specific perimetry for indirect comparison of different ganglion cell populations in glaucoma
    • Sample PA, Bosworth CF, Blumenthal EZ, Girkin C, Weinreb RN. Visual function-specific perimetry for indirect comparison of different ganglion cell populations in glaucoma. Invest Ophthalmol Vis Sci. 2000;41:1783-1790.
    • (2000) Invest Ophthalmol Vis Sci , vol.41 , pp. 1783-1790
    • Sample, P.A.1    Bosworth, C.F.2    Blumenthal, E.Z.3    Girkin, C.4    Weinreb, R.N.5
  • 25
    • 43149091417 scopus 로고    scopus 로고
    • Comparison of functional methods
    • Weinreb RN, Greve EL, eds, The Hague, The Netherlands: Kugler Publications;
    • Sample PA, Chauhan BC, Araie M, Johnson CA. Comparison of functional methods. In: Weinreb RN, Greve EL, eds. Glaucoma Diagnosis: Structure and Function. The Hague, The Netherlands: Kugler Publications; 2004:119-126.
    • (2004) Glaucoma Diagnosis: Structure and Function , pp. 119-126
    • Sample, P.A.1    Chauhan, B.C.2    Araie, M.3    Johnson, C.A.4
  • 26
    • 12844252397 scopus 로고    scopus 로고
    • Psychophysical investigation of ganglion cell loss in early glaucoma
    • Spry PG, Johnson CA, Mansberger SL, Cioffi GA. Psychophysical investigation of ganglion cell loss in early glaucoma. J Glaucoma. 2005;14:11-19.
    • (2005) J Glaucoma , vol.14 , pp. 11-19
    • Spry, P.G.1    Johnson, C.A.2    Mansberger, S.L.3    Cioffi, G.A.4
  • 27
    • 20444460729 scopus 로고    scopus 로고
    • Use of progressive glaucomatous optic disk change as the reference standard for evaluation of diagnostic tests in glaucoma
    • Medeiros FA, Zangwill LM, Bowd C, Sample PA, Weinreb RN. Use of progressive glaucomatous optic disk change as the reference standard for evaluation of diagnostic tests in glaucoma. Am J Ophthalmol. 2005;139:1010-1018.
    • (2005) Am J Ophthalmol , vol.139 , pp. 1010-1018
    • Medeiros, F.A.1    Zangwill, L.M.2    Bowd, C.3    Sample, P.A.4    Weinreb, R.N.5
  • 28
    • 0036190585 scopus 로고    scopus 로고
    • Standard achromatic perimetry, short wavelength automated perimetry, and frequency doubling technology for detection of glaucoma damage
    • Soliman MA, de Jong LA, Ismaeil AA, van den Berg TJ, de Smet MD. Standard achromatic perimetry, short wavelength automated perimetry, and frequency doubling technology for detection of glaucoma damage. Ophthalmology. 2002;109:444-454.
    • (2002) Ophthalmology , vol.109 , pp. 444-454
    • Soliman, M.A.1    de Jong, L.A.2    Ismaeil, A.A.3    van den Berg, T.J.4    de Smet, M.D.5
  • 29
    • 0023710206 scopus 로고
    • Comparing the areas under two or more correlated receiver operating characteristic curves: A nonparametric approach
    • DeLong ER, DeLong DM, Clarke-Pearson DL. Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics. 1988;44:837-845.
    • (1988) Biometrics , vol.44 , pp. 837-845
    • DeLong, E.R.1    DeLong, D.M.2    Clarke-Pearson, D.L.3
  • 30
    • 0036138639 scopus 로고    scopus 로고
    • Comparing machine learning classifiers for diagnosing glaucoma from standard automated perimetry
    • Goldbaum MH, Sample PA, Chan K, et al. Comparing machine learning classifiers for diagnosing glaucoma from standard automated perimetry. Invest Ophthalmol Vis Sci. 2002;43:162-169.
    • (2002) Invest Ophthalmol Vis Sci , vol.43 , pp. 162-169
    • Goldbaum, M.H.1    Sample, P.A.2    Chan, K.3
  • 31
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33:159-174.
    • (1977) Biometrics , vol.33 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 32
    • 0036734696 scopus 로고    scopus 로고
    • Comparison of glaucomatous visual field defects using standard full threshold and Swedish interactive threshold algorithms
    • Budenz DL, Rhee P, Feuer WJ, McSoley J, Johnson CA, Anderson DR. Comparison of glaucomatous visual field defects using standard full threshold and Swedish interactive threshold algorithms. Arch Ophthalmol. 2002;120:1136-1141.
    • (2002) Arch Ophthalmol , vol.120 , pp. 1136-1141
    • Budenz, D.L.1    Rhee, P.2    Feuer, W.J.3    McSoley, J.4    Johnson, C.A.5    Anderson, D.R.6
  • 33
    • 27644479250 scopus 로고    scopus 로고
    • The psychophysics of glaucoma: Improving the structure/function relationship
    • Anderson RS. The psychophysics of glaucoma: improving the structure/function relationship. Prog Retin Eye Res. 2005;25:79-97.
    • (2005) Prog Retin Eye Res , vol.25 , pp. 79-97
    • Anderson, R.S.1
  • 34
    • 0036323918 scopus 로고    scopus 로고
    • Structure and function evaluation (SAFE): I. Criteria for glaucomatous visual field loss using standard automated perimetry (SAP) and short wavelength automated perimetry (SWAP)
    • Johnson CA, Sample PA, Cioffi GA, Liebmann JR, Weinreb RN. Structure and function evaluation (SAFE): I. Criteria for glaucomatous visual field loss using standard automated perimetry (SAP) and short wavelength automated perimetry (SWAP). Am J Ophthalmol. 2002;134:177-185.
    • (2002) Am J Ophthalmol , vol.134 , pp. 177-185
    • Johnson, C.A.1    Sample, P.A.2    Cioffi, G.A.3    Liebmann, J.R.4    Weinreb, R.N.5
  • 35
    • 16644395164 scopus 로고    scopus 로고
    • An evaluation of algorithms designed to classify the results from frequency doubling perimetry
    • Muskens RP, Heeg GP, Jansonius NM. An evaluation of algorithms designed to classify the results from frequency doubling perimetry. Ophthalmic Physiol Opt. 2004;24:498-503.
    • (2004) Ophthalmic Physiol Opt , vol.24 , pp. 498-503
    • Muskens, R.P.1    Heeg, G.P.2    Jansonius, N.M.3
  • 36
    • 5044223952 scopus 로고    scopus 로고
    • Reversible changes in frequency-doubling perimetry with transiently elevated intraocular pressure
    • Fujimoto N, Zhang D, Sato E, Miyauchi O, Mizota A. Reversible changes in frequency-doubling perimetry with transiently elevated intraocular pressure. Arch Ophthalmol. 2004;122:1540-1543.
    • (2004) Arch Ophthalmol , vol.122 , pp. 1540-1543
    • Fujimoto, N.1    Zhang, D.2    Sato, E.3    Miyauchi, O.4    Mizota, A.5
  • 37
    • 0037323428 scopus 로고    scopus 로고
    • Concordance of highpass resolution perimetry and frequency-doubling technology perimetry results in glaucoma: No support for selective ganglion cell damage
    • Martin L, Wanger P, Vancea L, Gothlin B. Concordance of highpass resolution perimetry and frequency-doubling technology perimetry results in glaucoma: no support for selective ganglion cell damage. J Glaucoma. 2003;12:40-44.
    • (2003) J Glaucoma , vol.12 , pp. 40-44
    • Martin, L.1    Wanger, P.2    Vancea, L.3    Gothlin, B.4
  • 39
    • 17944390776 scopus 로고    scopus 로고
    • Effects of retinal ganglion cell loss on magno-, parvo-, koniocellular pathways in the lateral geniculate nucleus and visual cortex in glaucoma
    • Yucel YH, Zhang Q, Weinreb RN, Kaufman PL, Gupta N. Effects of retinal ganglion cell loss on magno-, parvo-, koniocellular pathways in the lateral geniculate nucleus and visual cortex in glaucoma. Prog Retin Eye Res. 2003;22:465-481.
    • (2003) Prog Retin Eye Res , vol.22 , pp. 465-481
    • Yucel, Y.H.1    Zhang, Q.2    Weinreb, R.N.3    Kaufman, P.L.4    Gupta, N.5
  • 40
    • 0030931708 scopus 로고    scopus 로고
    • Short-wavelength automated perimetry and motion automated perimetry in patients with glaucoma (see comments)
    • Sample PA, Bosworth CF, Weinreb RN. Short-wavelength automated perimetry and motion automated perimetry in patients with glaucoma (see comments). Arch Ophthalmol. 1997;115:1129-1133.
    • (1997) Arch Ophthalmol , vol.115 , pp. 1129-1133
    • Sample, P.A.1    Bosworth, C.F.2    Weinreb, R.N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.