메뉴 건너뛰기




Volumn , Issue , 2007, Pages 262-273

Advances in Energy Sources in Catheter Ablation

Author keywords

Arrhythmic propagation; Catheter ablation; Laser ablation; Myocardial injury; Radiofrequency ablation

Indexed keywords


EID: 33747208414     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1002/9780470988725.ch27     Document Type: Chapter
Times cited : (1)

References (53)
  • 1
    • 0024364286 scopus 로고
    • Tissue heating during radiofrequency catheter ablation: a thermodynamic model and observations in isolated perfused and superfused canine right ventricular free wall
    • Haines DE, Watson DD. Tissue heating during radiofrequency catheter ablation: a thermodynamic model and observations in isolated perfused and superfused canine right ventricular free wall. PACE 1989; 12(6): 962-976.
    • (1989) PACE , vol.12 , Issue.6 , pp. 962-976
    • Haines, D.E.1    Watson, D.D.2
  • 2
    • 0025293526 scopus 로고
    • Electrode radius predicts lesion radius during radiofrequency energy heating. Validation of a proposed thermodynamic model
    • Haines DE,Watson DD, Verow AF. Electrode radius predicts lesion radius during radiofrequency energy heating. Validation of a proposed thermodynamic model. Circ Rese 1990; 67(1): 124-912.
    • (1990) Circ Rese , vol.67 , Issue.1 , pp. 124-912
    • Haines, D.E.1    Watson, D.D.2    Verow, A.F.3
  • 3
    • 0028209986 scopus 로고
    • Microwave catheter ablation of myocardium in vitro. Assessment of the characteristics of tissue heating and injury
    • Whayne JG, Nath S, Haines DE. Microwave catheter ablation of myocardium in vitro. Assessment of the characteristics of tissue heating and injury. Circulation 1994; 89(5): 2390-2395.
    • (1994) Circulation , vol.89 , Issue.5 , pp. 2390-2395
    • Whayne, J.G.1    Nath, S.2    Haines, D.E.3
  • 4
    • 0026325244 scopus 로고
    • Determinants of lesion size during radiofrequency catheter ablation: the role of electrode tissue contact pressure and duration of energy delivery
    • Haines DE. Determinants of lesion size during radiofrequency catheter ablation: the role of electrode tissue contact pressure and duration of energy delivery. J Cardiovasc Electrophysiol 1991; 2: 509-515.
    • (1991) J Cardiovasc Electrophysiol , vol.2 , pp. 509-515
    • Haines, D.E.1
  • 5
    • 0028814037 scopus 로고
    • Myocardial temperature response during radiofrequency catheter ablation
    • Wittkampf FH, Simmers TA, Hauer RN, Robles De Medina EO. Myocardial temperature response during radiofrequency catheter ablation. PACE 1995; 18(2): 307-317.
    • (1995) PACE , vol.18 , Issue.2 , pp. 307-317
    • Wittkampf, F.H.1    Simmers, T.A.2    Hauer, R.N.3    Robles De Medina, E.O.4
  • 6
    • 0027438063 scopus 로고
    • Cellular electrophysiological effects of hyperthermia on isolated guinea pig papillary muscle. Implications for catheter ablation
    • Nath S, Lynch C III, Whayne JG, Haines DE. Cellular electrophysiological effects of hyperthermia on isolated guinea pig papillary muscle. Implications for catheter ablation. Circulation 1993; 88(4 Pt 1): 1826-1831.
    • (1993) Circulation , vol.88 , Issue.4 PT 1 , pp. 1826-1831
    • Nath, S.1    Lynch, C.I.I.I.2    Whayne, J.G.3    Haines, D.E.4
  • 7
    • 0028938319 scopus 로고
    • Effects of heating on impulse propagation in superfused canine myocardium
    • Simmers TA, de Bakker JM, Wittkampf FH, Hauer RN. Effects of heating on impulse propagation in superfused canine myocardium. J Am Coll Cardiol 1995; 25(6): 1457-1464.
    • (1995) J Am Coll Cardiol , vol.25 , Issue.6 , pp. 1457-1464
    • Simmers, T.A.1    de Bakker, J.M.2    Wittkampf, F.H.3    Hauer, R.N.4
  • 9
    • 0027942161 scopus 로고
    • Ultrastructural observations in the myocardium beyond the region of acute coagulation necrosis following radiofrequency catheter ablation
    • Nath S, Redick JA, Whayne JG, Haines DE. Ultrastructural observations in the myocardium beyond the region of acute coagulation necrosis following radiofrequency catheter ablation. J Cardiovasc Electrophysiol 1994; 5(10): 838-845.
    • (1994) J Cardiovasc Electrophysiol , vol.5 , Issue.10 , pp. 838-845
    • Nath, S.1    Redick, J.A.2    Whayne, J.G.3    Haines, D.E.4
  • 10
    • 0028240838 scopus 로고
    • Effects of radiofrequency catheter ablation on regional myocardial blood flow. Possible mechanism for late electrophysiological outcome
    • Nath S,Whayne JG, Kaul S, Goodman NC, Jayaweera AR, Haines DE. Effects of radiofrequency catheter ablation on regional myocardial blood flow. Possible mechanism for late electrophysiological outcome. Circulation 1994; 89(6): 2667-2672.
    • (1994) Circulation , vol.89 , Issue.6 , pp. 2667-2672
    • Nath, S.1    Whayne, J.G.2    Kaul, S.3    Goodman, N.C.4    Jayaweera, A.R.5    Haines, D.E.6
  • 12
    • 84882853994 scopus 로고    scopus 로고
    • Effect of application time on catheter cryoablation lesion size
    • Matsudaira K,Nakagawa H,Yamanashi WS et al. Effect of application time on catheter cryoablation lesion size. Circulation 2004; 102: II-526.
    • (2004) Circulation , vol.102
    • Matsudaira, K.1    Nakagawa, H.2    Yamanashi, W.S.3
  • 13
    • 0028942447 scopus 로고
    • Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation
    • Nakagawa H, Yamanashi WS, Pitha JV et al. Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation. Circulation 1995; 91(8): 2264-2273.
    • (1995) Circulation , vol.91 , Issue.8 , pp. 2264-2273
    • Nakagawa, H.1    Yamanashi, W.S.2    Pitha, J.V.3
  • 14
    • 0036665059 scopus 로고    scopus 로고
    • Primary closed cooled tip ablation of typical atrial flutter in comparison to conventional radiofrequency ablation
    • Spitzer SG, Karolyi L, Rammler C, Otto T. Primary closed cooled tip ablation of typical atrial flutter in comparison to conventional radiofrequency ablation. Europace 2002; 4(3): 265-271.
    • (2002) Europace , vol.4 , Issue.3 , pp. 265-271
    • Spitzer, S.G.1    Karolyi, L.2    Rammler, C.3    Otto, T.4
  • 15
    • 0344447087 scopus 로고    scopus 로고
    • Successful irrigated- tip catheter ablation of atrial flutter resistant to conventional radiofrequency ablation
    • Jais P, Haissaguerre M, Shah DC et al. Successful irrigated- tip catheter ablation of atrial flutter resistant to conventional radiofrequency ablation. Circulation 1998; 98(9): 835-838.
    • (1998) Circulation , vol.98 , Issue.9 , pp. 835-838
    • Jais, P.1    Haissaguerre, M.2    Shah, D.C.3
  • 16
    • 0035836538 scopus 로고    scopus 로고
    • Saline-cooled versus standard radiofrequency catheter ablation for infarct-related ventricular tachycardias
    • Soejima K, Delacretaz E, Suzuki M et al. Saline-cooled versus standard radiofrequency catheter ablation for infarct-related ventricular tachycardias. Circulation 2001; 103(14): 1858-1862.
    • (2001) Circulation , vol.103 , Issue.14 , pp. 1858-1862
    • Soejima, K.1    Delacretaz, E.2    Suzuki, M.3
  • 17
    • 0030686445 scopus 로고    scopus 로고
    • Nonuniform heating during radiofrequency ablation with long electrodes: monitoring the edge effect
    • McRury ID, Mitchell MA, Panescu D, Haines DE. Nonuniform heating during radiofrequency ablation with long electrodes: monitoring the edge effect. Circulation 1997; 96: 4057-4064.
    • (1997) Circulation , vol.96 , pp. 4057-4064
    • McRury, I.D.1    Mitchell, M.A.2    Panescu, D.3    Haines, D.E.4
  • 18
    • 0036162048 scopus 로고    scopus 로고
    • The effect of ablation electrode length and catheter tip to endocardial orientation on radiofrequency lesion size in the canine right atrium
    • Chan RC, Johnson SB, Seward JB, Packer DL. The effect of ablation electrode length and catheter tip to endocardial orientation on radiofrequency lesion size in the canine right atrium. PACE 2002; 25(1): 4-13.
    • (2002) PACE , vol.25 , Issue.1 , pp. 4-13
    • Chan, R.C.1    Johnson, S.B.2    Seward, J.B.3    Packer, D.L.4
  • 19
    • 0035038777 scopus 로고    scopus 로고
    • Ablation of atrial fibrillation in the rapid pacing canine model using a multi-electrode loop catheter
    • Avitall B, Urbonas A, Millard S, Urboniene D, Helms R. Ablation of atrial fibrillation in the rapid pacing canine model using a multi-electrode loop catheter. J Am Coll Cardiol 2001; 37(6): 1733-1740.
    • (2001) J Am Coll Cardiol , vol.37 , Issue.6 , pp. 1733-1740
    • Avitall, B.1    Urbonas, A.2    Millard, S.3    Urboniene, D.4    Helms, R.5
  • 20
    • 84889310114 scopus 로고    scopus 로고
    • A multicenter pre-clinical safety study using a single mesh catheter for mapping and radiofrequency delivery: a simplified approach to pulmonary vein isolation
    • Arruda M, Wilber DJ, Nakagawa H et al. A multicenter pre-clinical safety study using a single mesh catheter for mapping and radiofrequency delivery: a simplified approach to pulmonary vein isolation. Heart Rhythm 2004; 1(1): s171.
    • (2004) Heart Rhythm , vol.1 , Issue.1
    • Arruda, M.1    Wilber, D.J.2    Nakagawa, H.3
  • 21
    • 0033578467 scopus 로고    scopus 로고
    • Is 8-mm more effective than 4-mm tip electrode catheter for ablation of typical atrial flutter?
    • Tsai CF, Tai CT, Yu WC et al. Is 8-mm more effective than 4-mm tip electrode catheter for ablation of typical atrial flutter? Circulation 1999; 100(7): 768-771.
    • (1999) Circulation , vol.100 , Issue.7 , pp. 768-771
    • Tsai, C.F.1    Tai, C.T.2    Yu, W.C.3
  • 22
    • 0034332724 scopus 로고    scopus 로고
    • Comparison of effectiveness of an 8-mm versus a 4-mm tip electrode catheter for radiofrequency ablation of typical atrial flutter
    • Kasai A, Anselme F, Teo WS, Cribier A, Saoudi N. Comparison of effectiveness of an 8-mm versus a 4-mm tip electrode catheter for radiofrequency ablation of typical atrial flutter. Am J Cardiol 2000; 86(9): 1029-1032, A10.
    • (2000) Am J Cardiol , vol.86 , Issue.9
    • Kasai, A.1    Anselme, F.2    Teo, W.S.3    Cribier, A.4    Saoudi, N.5
  • 23
    • 0033958111 scopus 로고    scopus 로고
    • Comparison of results of an 8-mm split-tip versus a 4-mm tip ablation catheter to perform radiofrequency ablation of type I atrial flutter
    • Rodriguez LM, Nabar A, Timmermans C, Wellens HJ. Comparison of results of an 8-mm split-tip versus a 4-mm tip ablation catheter to perform radiofrequency ablation of type I atrial flutter. Am J Cardiol 2000; 85(1): 109-112, A9.
    • (2000) Am J Cardiol , vol.85 , Issue.1
    • Rodriguez, L.M.1    Nabar, A.2    Timmermans, C.3    Wellens, H.J.4
  • 24
    • 1942423054 scopus 로고    scopus 로고
    • In vitro and in vivo evaluation of the thermal patterns and lesions of catheter ablation with a microwave monopole antenna
    • Keane D, Ruskin J, Norris N, Chapelon PA, Berube D. In vitro and in vivo evaluation of the thermal patterns and lesions of catheter ablation with a microwave monopole antenna. J Interv Card Electrophysiol 2004; 10(2): 111-119.
    • (2004) J Interv Card Electrophysiol , vol.10 , Issue.2 , pp. 111-119
    • Keane, D.1    Ruskin, J.2    Norris, N.3    Chapelon, P.A.4    Berube, D.5
  • 25
    • 0037251506 scopus 로고    scopus 로고
    • Microwave, irrigated, pulsed, or conventional radiofrequency energy source: which energy source for which catheter ablation?
    • Erdogan A, Grumbrecht S, Neumann T, Neuzner J, Pitschner HF. Microwave, irrigated, pulsed, or conventional radiofrequency energy source: which energy source for which catheter ablation? PACE 2003; 26(1 Pt 2): 504-506.
    • (2003) PACE , vol.26 , Issue.1 PT 2 , pp. 504-506
    • Erdogan, A.1    Grumbrecht, S.2    Neumann, T.3    Neuzner, J.4    Pitschner, H.F.5
  • 26
    • 0033963508 scopus 로고    scopus 로고
    • Microwave ablation using a spiral antenna design in a porcine thigh muscle preparation: in vivo assessment of temperature profile and lesion geometry
    • VanderBrink BA, Gu Z, Rodriguez V et al. Microwave ablation using a spiral antenna design in a porcine thigh muscle preparation: in vivo assessment of temperature profile and lesion geometry. J Cardiovasc Electrophysiol 2000; 11(2): 193-198.
    • (2000) J Cardiovasc Electrophysiol , vol.11 , Issue.2 , pp. 193-198
    • VanderBrink, B.A.1    Gu, Z.2    Rodriguez, V.3
  • 27
    • 0034065874 scopus 로고    scopus 로고
    • Safety and efficacy of a steerable temperature monitoring microwave catheter system for ventricular myocardial ablation
    • VanderBrink BA, Gilbride C, Aronovitz MJ et al. Safety and efficacy of a steerable temperature monitoring microwave catheter system for ventricular myocardial ablation. J Cardiovasc Electrophysiol 2000; 11(3): 305-310.
    • (2000) J Cardiovasc Electrophysiol , vol.11 , Issue.3 , pp. 305-310
    • VanderBrink, B.A.1    Gilbride, C.2    Aronovitz, M.J.3
  • 28
    • 0036657473 scopus 로고    scopus 로고
    • Combined atrial fibrillation and mitral valve surgery using microwave technology
    • Knaut M, Tugtekin SM, Spitzer S, Gulielmos V. Combined atrial fibrillation and mitral valve surgery using microwave technology. Semin Thorac Cardiovasc Surg 2002; 14(3): 226-231.
    • (2002) Semin Thorac Cardiovasc Surg , vol.14 , Issue.3 , pp. 226-231
    • Knaut, M.1    Tugtekin, S.M.2    Spitzer, S.3    Gulielmos, V.4
  • 29
    • 0033387607 scopus 로고    scopus 로고
    • Intraoperative microwave ablation for curative treatment of atrial fibrillation in open heart surgery - the MICRO-STAF and MICRO-PASS pilot trial. MICROwave application in surgical treatment of atrial fibrillation. MICROwave application for the treatment of atrial fibrillation in bypass-surgery
    • Knaut M, Spitzer SG, Karolyi L et al. Intraoperative microwave ablation for curative treatment of atrial fibrillation in open heart surgery - the MICRO-STAF and MICRO-PASS pilot trial. MICROwave application in surgical treatment of atrial fibrillation. MICROwave application for the treatment of atrial fibrillation in bypass-surgery. Thorac Cardiovasc Surg 1999; 47(Suppl 3): 379-384.
    • (1999) Thorac Cardiovasc Surg , vol.47 , Issue.SUPPL. 3 , pp. 379-384
    • Knaut, M.1    Spitzer, S.G.2    Karolyi, L.3
  • 30
    • 0141609080 scopus 로고    scopus 로고
    • Surgical treatment of permanent atrial fibrillation using microwave energy ablation: a prospective randomized clinical trial
    • discussion 480
    • Schuetz A, Schulze CJ, Sarvanakis KK et al. Surgical treatment of permanent atrial fibrillation using microwave energy ablation: a prospective randomized clinical trial. Eur J Cardiothorac Surg 2003; 24(4): 475-480; discussion 480.
    • (2003) Eur J Cardiothorac Surg , vol.24 , Issue.4 , pp. 475-480
    • Schuetz, A.1    Schulze, C.J.2    Sarvanakis, K.K.3
  • 31
    • 0033783375 scopus 로고    scopus 로고
    • Linear lesions in myocardium created by Nd : YAG laser using diffusing optical fibers: in vitro and in vivo results
    • Fried NM, Lardo AC, Berger RD,Calkins H,Halperin HR. Linear lesions in myocardium created by Nd : YAG laser using diffusing optical fibers: in vitro and in vivo results. Lasers Surg Medi 2000; 27(4): 295-304.
    • (2000) Lasers Surg Medi , vol.27 , Issue.4 , pp. 295-304
    • Fried, N.M.1    Lardo, A.C.2    Berger, R.D.3    Calkins, H.4    Halperin, H.R.5
  • 32
    • 0033616849 scopus 로고    scopus 로고
    • Slow intramural heating with diffused laser light: a unique method for deep myocardial coagulation
    • Ware DL, Boor P,Yang C,Gowda A,Grady JJ,Motamedi M. Slow intramural heating with diffused laser light: a unique method for deep myocardial coagulation. Circulation 1999; 99(12): 1630-1636.
    • (1999) Circulation , vol.99 , Issue.12 , pp. 1630-1636
    • Ware, D.L.1    Boor, P.2    Yang, C.3    Gowda, A.4    Grady, J.J.5    Motamedi, M.6
  • 33
    • 0035073660 scopus 로고    scopus 로고
    • Laser ablation of the pulmonary veins by using a fiberoptic balloon catheter: implications for treatment of paroxysmal atrial fibrillation
    • Fried NM, Tsitlik A, Rent KC et al. Laser ablation of the pulmonary veins by using a fiberoptic balloon catheter: implications for treatment of paroxysmal atrial fibrillation. Lasers Surg Med 2001; 28(3): 197-203.
    • (2001) Lasers Surg Med , vol.28 , Issue.3 , pp. 197-203
    • Fried, N.M.1    Tsitlik, A.2    Rent, K.C.3
  • 34
    • 0036161658 scopus 로고    scopus 로고
    • Fiberoptic balloon catheter ablation of pulmonary vein ostia in pigs using photonic energy delivery with diode laser
    • Lemery R, Veinot JP, Tang AS et al. Fiberoptic balloon catheter ablation of pulmonary vein ostia in pigs using photonic energy delivery with diode laser. PACE 2002; 25(1): 32-36.
    • (2002) PACE , vol.25 , Issue.1 , pp. 32-36
    • Lemery, R.1    Veinot, J.P.2    Tang, A.S.3
  • 35
    • 9144272549 scopus 로고    scopus 로고
    • Use of a diode laser balloon ablation catheter to generate circumferential pulmonary venous lesions in an open-thoracotomy caprine model
    • Reddy VY, Houghtaling C, Fallon J et al. Use of a diode laser balloon ablation catheter to generate circumferential pulmonary venous lesions in an open-thoracotomy caprine model. PACE 2004; 27(1): 52-57.
    • (2004) PACE , vol.27 , Issue.1 , pp. 52-57
    • Reddy, V.Y.1    Houghtaling, C.2    Fallon, J.3
  • 36
    • 0024331133 scopus 로고
    • Argon laser ablation of malignant ventricular tachycardia associated with coronary artery disease
    • Saksena S, Gielchinsky I, Tullo NG. Argon laser ablation of malignant ventricular tachycardia associated with coronary artery disease. Am J Cardiol 1989; 64(19): 1298-1304.
    • (1989) Am J Cardiol , vol.64 , Issue.19 , pp. 1298-1304
    • Saksena, S.1    Gielchinsky, I.2    Tullo, N.G.3
  • 37
    • 0030470974 scopus 로고    scopus 로고
    • Epicardial neodymium. YAG laser photocoagulation of ventricular tachycardia without ventriculotomy in patients after myocardial infarction
    • Pfeiffer D, Moosdorf R, Svenson RH et al. Epicardial neodymium. YAG laser photocoagulation of ventricular tachycardia without ventriculotomy in patients after myocardial infarction. Circulation 1996; 94(12): 3221-3225.
    • (1996) Circulation , vol.94 , Issue.12 , pp. 3221-3225
    • Pfeiffer, D.1    Moosdorf, R.2    Svenson, R.H.3
  • 38
    • 0031046376 scopus 로고    scopus 로고
    • Laser catheter coagulation of atrial myocardium for ablation of atrioventricular nodal reentrant tachycardia. First clinical experience
    • Weber HP, Kaltenbrunner W, Heinze A, Steinbach K. Laser catheter coagulation of atrial myocardium for ablation of atrioventricular nodal reentrant tachycardia. First clinical experience. Eur Heart J 1997; 18(3): 487-495.
    • (1997) Eur Heart J , vol.18 , Issue.3 , pp. 487-495
    • Weber, H.P.1    Kaltenbrunner, W.2    Heinze, A.3    Steinbach, K.4
  • 39
    • 0038307096 scopus 로고    scopus 로고
    • Usefulness of a new radiofrequency thermal balloon catheter for pulmonary vein isolation: a new device for treatment of atrial fibrillation
    • Satake S, Tanaka K, Saito S et al. Usefulness of a new radiofrequency thermal balloon catheter for pulmonary vein isolation: a new device for treatment of atrial fibrillation. J Cardiovasc Electrophysiol 2003; 14(6): 609-615.
    • (2003) J Cardiovasc Electrophysiol , vol.14 , Issue.6 , pp. 609-615
    • Satake, S.1    Tanaka, K.2    Saito, S.3
  • 40
    • 84889362723 scopus 로고    scopus 로고
    • Beta radiation for pulmonary vein isolation
    • Mangrum JM, Sih H, Molloy J et al. Beta radiation for pulmonary vein isolation. Circulation 2002; 106: II-631.
    • (2002) Circulation , vol.106
    • Mangrum, J.M.1    Sih, H.2    Molloy, J.3
  • 41
    • 0034680347 scopus 로고    scopus 로고
    • First human experience with pulmonary vein isolation using a through-the-balloon circumferential ultrasound ablation system for recurrent atrial fibrillation
    • Natale A, Pisano E, Shewchik J et al. First human experience with pulmonary vein isolation using a through-the-balloon circumferential ultrasound ablation system for recurrent atrial fibrillation. Circulation 2000; 102(16): 1879-1882.
    • (2000) Circulation , vol.102 , Issue.16 , pp. 1879-1882
    • Natale, A.1    Pisano, E.2    Shewchik, J.3
  • 42
    • 2942675461 scopus 로고    scopus 로고
    • Ultrasound ablation of pulmonary veins for treatment of paroxysmal atrial fibrillation
    • Wang JA, Sun Y,He H. Ultrasound ablation of pulmonary veins for treatment of paroxysmal atrial fibrillation. J Zhejiang Univ (Sci) 2003; 4(6): 745-748.
    • (2003) J Zhejiang Univ (Sci) , vol.4 , Issue.6 , pp. 745-748
    • Wang, J.A.1    Sun, Y.2    He, H.3
  • 43
    • 0037532650 scopus 로고    scopus 로고
    • Initial experience with a novel focused ultrasound ablation system for ring ablation outside the pulmonary vein
    • Meininger GR, Calkins H, Lickfett L et al. Initial experience with a novel focused ultrasound ablation system for ring ablation outside the pulmonary vein. J Interv Card Electrophysiol 2003; 8(2): 141-148.
    • (2003) J Interv Card Electrophysiol , vol.8 , Issue.2 , pp. 141-148
    • Meininger, G.R.1    Calkins, H.2    Lickfett, L.3
  • 44
    • 0037461289 scopus 로고    scopus 로고
    • Lower incidence of thrombus formation with cryoenergy versus radiofrequency catheter ablation
    • Khairy P, Chauvet P, Lehmann J et al. Lower incidence of thrombus formation with cryoenergy versus radiofrequency catheter ablation. Circulation 2003; 107(15): 2045-2050.
    • (2003) Circulation , vol.107 , Issue.15 , pp. 2045-2050
    • Khairy, P.1    Chauvet, P.2    Lehmann, J.3
  • 45
    • 0036817370 scopus 로고    scopus 로고
    • Catheter-based cryoablation produces permanent bidirectional cavotricuspid isthmus conduction block in dogs
    • Timmermans C, Rodriguez LM, Van Suylen RJ et al. Catheter-based cryoablation produces permanent bidirectional cavotricuspid isthmus conduction block in dogs. J Interv Card Electrophysiol 2002; 7(2): 149-155.
    • (2002) J Interv Card Electrophysiol , vol.7 , Issue.2 , pp. 149-155
    • Timmermans, C.1    Rodriguez, L.M.2    Van Suylen, R.J.3
  • 46
    • 0034610437 scopus 로고    scopus 로고
    • Cryothermal ablation of the slow pathway for the elimination of atrioventricular nodal reentrant tachycardia
    • Skanes AC,Dubuc M, Klein GJ et al. Cryothermal ablation of the slow pathway for the elimination of atrioventricular nodal reentrant tachycardia. Circulation 2000; 102(23): 2856-2860.
    • (2000) Circulation , vol.102 , Issue.23 , pp. 2856-2860
    • Skanes, A.C.1    Dubuc, M.2    Klein, G.J.3
  • 47
    • 0038287873 scopus 로고    scopus 로고
    • Percutaneous catheter cryothermal ablation of atrioventricular nodal reentrant tachycardia: efficacy and safety of a new ablation technique
    • Riccardi R, Gaita F, Caponi D et al. Percutaneous catheter cryothermal ablation of atrioventricular nodal reentrant tachycardia: efficacy and safety of a new ablation technique. Italian Heart J: Off J Italian Fed Cardiol 2003; 4(1): 35-43.
    • (2003) Italian Heart J: Off J Italian Fed Cardiol , vol.4 , Issue.1 , pp. 35-43
    • Riccardi, R.1    Gaita, F.2    Caponi, D.3
  • 48
    • 0042154116 scopus 로고    scopus 로고
    • Safety and efficacy of cryoablation of accessory pathways adjacent to the normal conduction system
    • Gaita F, Haissaguerre M, Giustetto C et al. Safety and efficacy of cryoablation of accessory pathways adjacent to the normal conduction system. J Cardiovasc Electrophysiol 2003; 14(8): 825-829.
    • (2003) J Cardiovasc Electrophysiol , vol.14 , Issue.8 , pp. 825-829
    • Gaita, F.1    Haissaguerre, M.2    Giustetto, C.3
  • 49
    • 3042857297 scopus 로고    scopus 로고
    • Catheter cryoablation of supraventricular tachycardia: results of the multicenter prospective "frosty" trial
    • Friedman PA, Dubuc M, Green MS et al. Catheter cryoablation of supraventricular tachycardia: results of the multicenter prospective "frosty" trial. Heart Rhythm 2004; 1: 129-138.
    • (2004) Heart Rhythm , vol.1 , pp. 129-138
    • Friedman, P.A.1    Dubuc, M.2    Green, M.S.3
  • 50
    • 0037432308 scopus 로고    scopus 로고
    • Randomized study comparing radiofrequency ablation with cryoablation for the treatment of atrial flutter with emphasis on pain perception
    • Timmermans C, Ayers GM, Crijns HJ, Rodriguez LM. Randomized study comparing radiofrequency ablation with cryoablation for the treatment of atrial flutter with emphasis on pain perception. Circulation 2003; 107(9): 1250-1252.
    • (2003) Circulation , vol.107 , Issue.9 , pp. 1250-1252
    • Timmermans, C.1    Ayers, G.M.2    Crijns, H.J.3    Rodriguez, L.M.4
  • 51
    • 1842854735 scopus 로고    scopus 로고
    • Percutaneous isolation of multiple pulmonary veins using an expandable circular cryoablation catheter
    • Wong T, Markides V, Peters NS,Wright AR, Davies DW. Percutaneous isolation of multiple pulmonary veins using an expandable circular cryoablation catheter. PACE 2004; 27(4): 551-554.
    • (2004) PACE , vol.27 , Issue.4 , pp. 551-554
    • Wong, T.1    Markides, V.2    Peters, N.S.3    Wright, A.R.4    Davies, D.W.5
  • 53
    • 0037532650 scopus 로고    scopus 로고
    • Initial experience with a novel focused ultrasound ablation system for ring ablation outside the pulmonary vein
    • Meininger GR, Calkins H, Lickfett L et al. Initial experience with a novel focused ultrasound ablation system for ring ablation outside the pulmonary vein. J Interv Card Electrophysiol 2003; 8(2): 141-148.
    • (2003) J Interv Card Electrophysiol , vol.8 , Issue.2 , pp. 141-148
    • Meininger, G.R.1    Calkins, H.2    Lickfett, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.