메뉴 건너뛰기




Volumn 26, Issue 1 II, 2003, Pages 504-506

Microwave, irrigated, pulsed, or conventional radiofrequency energy source: Which energy source for which catheter ablation?

Author keywords

Irrigated catheter; Microwave; Pulsed energy delivery; Radiofrequency catheter ablation

Indexed keywords

ANIMAL TISSUE; APPARATUS; CALCULATION; CATHETER; CATHETER ABLATION; CONFERENCE PAPER; COOLING; ELECTRODE; ENERGY; HEART ARRHYTHMIA; HEART MUSCLE; IMPEDANCE; MICROWAVE RADIATION; NONHUMAN; RADIOFREQUENCY; SWINE; TEMPERATURE MEASUREMENT; TIME;

EID: 0037251506     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1460-9592.2003.00082.x     Document Type: Conference Paper
Times cited : (21)

References (11)
  • 1
    • 0026776722 scopus 로고
    • Treatment of supraventricular tachycardia due to atrioventricular nodal reentry, by radiofrequency catheter ablation of slow-pathway conduction
    • Jackman WM, Beckman KJ, McClelland JH, et al. Treatment of supraventricular tachycardia due to atrioventricular nodal reentry, by radiofrequency catheter ablation of slow-pathway conduction. N Engl J Med 1992; 327:313-318.
    • (1992) N Engl J Med , vol.327 , pp. 313-318
    • Jackman, W.M.1    Beckman, K.J.2    McClelland, J.H.3
  • 2
    • 0026583529 scopus 로고
    • Radiofrequency catheter ablation of accessory atrioventricular connections in 250 patients
    • Calkins H, Langberg J, Sousa J, et al. Radiofrequency catheter ablation of accessory atrioventricular connections in 250 patients. Circulation 1992; 85:1337-1346.
    • (1992) Circulation , vol.85 , pp. 1337-1346
    • Calkins, H.1    Langberg, J.2    Sousa, J.3
  • 3
    • 0027534580 scopus 로고
    • Radiofrequency ablation of the inferior vena cava-tricuspid valve isthmus in common atrial flutter
    • Cosio FG, Lopez-Gil M, Goicolea A, et al. Radiofrequency ablation of the inferior vena cava-tricuspid valve isthmus in common atrial flutter. Am J Cardiol 1993; 71:705-709.
    • (1993) Am J Cardiol , vol.71 , pp. 705-709
    • Cosio, F.G.1    Lopez-Gil, M.2    Goicolea, A.3
  • 4
    • 0347223188 scopus 로고    scopus 로고
    • Right and left radiofrequency catheter therapy of paroxysmal atrial fibrillation
    • Haissaguerre M, Jais P, Shah DC, et al. Right and left radiofrequency catheter therapy of paroxysmal atrial fibrillation. J Cardiovasc Electrophysiol 1996; 7:1132-1144.
    • (1996) J Cardiovasc Electrophysiol , vol.7 , pp. 1132-1144
    • Haissaguerre, M.1    Jais, P.2    Shah, D.C.3
  • 5
    • 0025095887 scopus 로고
    • Radiofrequency catheter ablation: The effect of electrode size on lesion volume in vivo
    • Langsberg JJ, Lee MA, Chin MC, et al. Radiofrequency catheter ablation: The effect of electrode size on lesion volume in vivo. PACE 1990; 13:1242-1248.
    • (1990) PACE , vol.13 , pp. 1242-1248
    • Langsberg, J.J.1    Lee, M.A.2    Chin, M.C.3
  • 6
    • 0028877525 scopus 로고
    • Biophysics and pathology of catheter energy delivery systems
    • Nath S, Haines DE. Biophysics and pathology of catheter energy delivery systems. Prog Cardiovasc Dis 1995; 37:185-204.
    • (1995) Prog Cardiovasc Dis , vol.37 , pp. 185-204
    • Nath, S.1    Haines, D.E.2
  • 7
    • 0033671193 scopus 로고    scopus 로고
    • Comparison of pulsed versus continuous radiofrequency energy delivery: Diameter of lesions induced with multipolar ablation catheter
    • Erdogan A, Carlsson J, Roederich H, et al. Comparison of pulsed versus continuous radiofrequency energy delivery: Diameter of lesions induced with multipolar ablation catheter. PACE 2000; 23:1852-1855.
    • (2000) PACE , vol.23 , pp. 1852-1855
    • Erdogan, A.1    Carlsson, J.2    Roederich, H.3
  • 8
    • 0035035553 scopus 로고    scopus 로고
    • Linear Ablation using irrigated electrode electrophysiologic and histologic lesion evolution comparison with ablation utilizing a non-irrigated electrode
    • Schwartzmann D, Parizhskaya M, Devine WA. Linear Ablation using irrigated electrode electrophysiologic and histologic lesion evolution comparison with ablation utilizing a non-irrigated electrode. J Interv Card Electrophysiol 2001; 5:17-26.
    • (2001) J Interv Card Electrophysiol , vol.5 , pp. 17-26
    • Schwartzmann, D.1    Parizhskaya, M.2    Devine, W.A.3
  • 9
    • 0032954274 scopus 로고    scopus 로고
    • Microwave ablation of myocardial tissue: The effect of element design, tissue coupling, blood flow, power, and duration of exposure on lesion size
    • Thomas SP, Clout R, Deery C, et al. Microwave ablation of myocardial tissue: The effect of element design, tissue coupling, blood flow, power, and duration of exposure on lesion size. J Cardiovasc Electrophysiol 1999; 10:72-78.
    • (1999) J Cardiovasc Electrophysiol , vol.10 , pp. 72-78
    • Thomas, S.P.1    Clout, R.2    Deery, C.3
  • 10
    • 0034848801 scopus 로고    scopus 로고
    • Effect of linear, irrigated-tip radiofrequency ablation in porcine healed anterior infarction
    • Callans D, Jian-Fang R, Narula N, et al. Effect of linear, irrigated-tip radiofrequency ablation in porcine healed anterior infarction. J Cardiovasc Electrophysiol 2001; 12:1037-1042.
    • (2001) J Cardiovasc Electrophysiol , vol.12 , pp. 1037-1042
    • Callans, D.1    Jian-Fang, R.2    Narula, N.3
  • 11
    • 0034848593 scopus 로고    scopus 로고
    • Irrigated radiofrequency catheter ablation
    • Keane D. Irrigated radiofrequency catheter ablation. J Cardiovasc Electrophysiol 2001; 12:1043-1045.
    • (2001) J Cardiovasc Electrophysiol , vol.12 , pp. 1043-1045
    • Keane, D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.