Volumn 7, Issue 2, 2002, Pages 149-155

Catheter-based cryoablation produces permanent bidirectional cavotricuspid isthmus conduction block in dogs

Author keywords

Catheter based cryoablation; Cavotricuspid isthmus; Radiofrequency ablation

Indexed keywords

ANIMAL CELL; ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ARTICLE; CATHETER ABLATION; CONTROLLED STUDY; CRYOSURGERY; DOG; EPICARDIUM MAPPING; HEART CONDUCTION; NONHUMAN; PRIORITY JOURNAL; RADIOFREQUENCY RADIATION; REENTRY ARRHYTHMIA;

EID: 0036817370     PISSN: 1383875X     EISSN: None     Source Type: Journal    
DOI: 10.1023/A:1020885721262     Document Type: Article
Times cited : (25)

References (14)
  • 1
    • 0033958111 scopus 로고    scopus 로고
    • Comparison of results of an 8-mm split-tip versus a 4-mm tip ablation catheter to perform radiofrequency ablation of type I atrial flutter
    • Rodriguez LM, Nabar A, Timmermans C, Wellens HJJ. Comparison of results of an 8-mm split-tip versus a 4-mm tip ablation catheter to perform radiofrequency ablation of type I atrial flutter. Am J Cardiol 2000;85:109-112.
    • (2000) Am J Cardiol , vol.85 , pp. 109-112
    • Rodriguez, L.M.1    Nabar, A.2    Timmermans, C.3    Wellens, H.J.J.4
  • 5
    • 0035058539 scopus 로고    scopus 로고
    • Catheter cryoablation of the atrioventricular node in patients with atrial fibrillation: A novel technology for ablation of cardiac arrhythmias
    • Dubuc M, Khairy P, Rodriguez-Santiago A, Talajic M, Tardif JC, Thibault B, Roy D. Catheter cryoablation of the atrioventricular node in patients with atrial fibrillation: A novel technology for ablation of cardiac arrhythmias. J Cardiovasc Electrophysiol 2001;12:439-444.
    • (2001) J Cardiovasc Electrophysiol , vol.12 , pp. 439-444
    • Dubuc, M.1    Khairy, P.2    Rodriguez-Santiago, A.3    Talajic, M.4    Tardif, J.C.5    Thibault, B.6    Roy, D.7
  • 7
    • 0032560634 scopus 로고    scopus 로고
    • New method for nonfluoroscopic endocardial mapping in humans. Accuracy assessment and first clinical results
    • Smeets JLRM, Ben-Haim SA, Rodriguez LM, Timmermans C, Wellens HJJ. New method for nonfluoroscopic endocardial mapping in humans. Accuracy assessment and first clinical results. Circulation 1998;97:2426-2432.
    • (1998) Circulation , vol.97 , pp. 2426-2432
    • Smeets, J.L.R.M.1    Ben-Haim, S.A.2    Rodriguez, L.M.3    Timmermans, C.4    Wellens, H.J.J.5
  • 9
    • 0023006086 scopus 로고
    • Closed-heart technique for Wolff-Parkinson-White syndrome: Further experience and potential limitations
    • Guiraudon GM, Klein GJ, Sharma AD, Milstein S, McLellan DG. Closed-heart technique for Wolff-Parkinson-White syndrome: Further experience and potential limitations. Ann Thorac Surg 1986;42:651-657.
    • (1986) Ann Thorac Surg , vol.42 , pp. 651-657
    • Guiraudon, G.M.1    Klein, G.J.2    Sharma, A.D.3    Milstein, S.4    McLellan, D.G.5
  • 12
    • 0031795163 scopus 로고    scopus 로고
    • The architecture of the atrial musculature between the orifice of the inferior caval vein and the tricuspid valve: The anatomy of the isthmus
    • Cabrera JA, Sanchez-Quintana D, Ho SY, Medina A, Anderson RH. The architecture of the atrial musculature between the orifice of the inferior caval vein and the tricuspid valve: The anatomy of the isthmus. J Cardiovasc Electrophysiol 1998;9:1186-1195.
    • (1998) J Cardiovasc Electrophysiol , vol.9 , pp. 1186-1195
    • Cabrera, J.A.1    Sanchez-Quintana, D.2    Ho, S.Y.3    Medina, A.4    Anderson, R.H.5
  • 13
    • 0033055475 scopus 로고    scopus 로고
    • Blood damage, platelet and clotting activation during application of radiofrequency or cryoablation catheters: A comparative in vitro study
    • Van Oeveren W, Crijns HJGM, Korteling BJ, Wegereef EW, Haan J, Tigchelaar I, Hoekstra A. Blood damage, platelet and clotting activation during application of radiofrequency or cryoablation catheters: A comparative in vitro study. J Med Eng Technol 1999;23:20-25.
    • (1999) J Med Eng Technol , vol.23 , pp. 20-25
    • Van Oeveren, W.1    Crijns, H.J.G.M.2    Korteling, B.J.3    Wegereef, E.W.4    Haan, J.5    Tigchelaar, I.6    Hoekstra, A.7
  • 14
    • 0032959646 scopus 로고    scopus 로고
    • Thromboembolic complications of cardiac radiofrequency catheter ablation: A review of the reported incidence, pathogenesis and current research directions
    • Zhou L, Keane D, Reed G, Ruskin J. Thromboembolic complications of cardiac radiofrequency catheter ablation: A review of the reported incidence, pathogenesis and current research directions. J Cardiovasc Electrophysiol 1999;10:611-620.
    • (1999) J Cardiovasc Electrophysiol , vol.10 , pp. 611-620
    • Zhou, L.1    Keane, D.2    Reed, G.3    Ruskin, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.