메뉴 건너뛰기




Volumn 3, Issue , 2003, Pages 1723-1727

Time determination of BGO-APD detectors by digital signal processing for Positron Emission Tomography

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; ANALOG TO DIGITAL CONVERSION; DIGITAL SIGNAL PROCESSING; FIELD PROGRAMMABLE GATE ARRAYS; IMAGE QUALITY; NUMERICAL ANALYSIS; RANDOM ACCESS STORAGE; SIGNAL TO NOISE RATIO;

EID: 11844271473     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/nssmic.2003.1352211     Document Type: Conference Paper
Times cited : (22)

References (10)
  • 1
    • 0028493624 scopus 로고
    • Design and engineering aspects of a high resolution positron tomography for small animal imaging
    • R. Lecomte et al. "Design and engineering aspects of a high resolution positron tomography for small animal imaging", IEEE Trans. Nucl. Sci., vol. 41, no. 4, 1994.
    • (1994) IEEE Trans. Nucl. Sci. , vol.41 , Issue.4
    • Lecomte, R.1
  • 2
    • 0035207974 scopus 로고    scopus 로고
    • Instrumentation and methodology for quantitative pre-clinical imaging studies
    • S. R. Meikle, S. Eberl, H. Iida, "Instrumentation and methodology for quantitative pre-clinical imaging studies", Curr. Pharmaceut. Design, vol. 7, pp. 1945-1966, 2001.
    • (2001) Curr. Pharmaceut. Design , vol.7 , pp. 1945-1966
    • Meikle, S.R.1    Eberl, S.2    Iida, H.3
  • 5
    • 0024686069 scopus 로고
    • Status of BGO-avalanche photodiode detectors for spectroscopic and timing applications
    • R. Lecomte, C. Martel, C. Carrier, "Status of BGO-avalanche photodiode detectors for spectroscopic and timing applications", Nucl. Instrum. Meth. Phys. Res. A, vol. 278, pp. 585-597, 1989.
    • (1989) Nucl. Instrum. Meth. Phys. Res. A , vol.278 , pp. 585-597
    • Lecomte, R.1    Martel, C.2    Carrier, C.3
  • 6
    • 0036815735 scopus 로고    scopus 로고
    • Design of a fast shaping amplifier for PET/CT APD detectors with depth-of-interaction
    • J.-F. Pratte et al., "Design of a fast shaping amplifier for PET/CT APD detectors with depth-of-interaction", IEEE Trans. Nucl. Sci., vol. 49, no. 5, pp. 2448-2454.
    • IEEE Trans. Nucl. Sci. , vol.49 , Issue.5 , pp. 2448-2454
    • Pratte, J.-F.1
  • 8
    • 0035355031 scopus 로고    scopus 로고
    • Performance analysis of phoswich/APD detectors and low-noise CMOS preamplifiers for high-resolution PET systems
    • R. Lecomte et al. "Performance analysis of phoswich/APD detectors and low-noise CMOS preamplifiers for high-resolution PET systems", IEEE Trans. Nucl. Sci., vol. 48, no. 3, pp. 650-655.
    • IEEE Trans. Nucl. Sci. , vol.48 , Issue.3 , pp. 650-655
    • Lecomte, R.1
  • 9
    • 0034204935 scopus 로고    scopus 로고
    • A power-efficient, low-noise, wideband, integrated CMOS preamplifier for LSO/APD PET systems
    • D. M. Binkley, B. S. Puckett, M. E. Casey, R. Lecomte, A. Saoudi, "A power-efficient, low-noise, wideband, integrated CMOS preamplifier for LSO/APD PET systems", IEEE Trans. Nucl. Sci., vol. 47, no. 3, pp. 810-817, 2000.
    • (2000) IEEE Trans. Nucl. Sci. , vol.47 , Issue.3 , pp. 810-817
    • Binkley, D.M.1    Puckett, B.S.2    Casey, M.E.3    Lecomte, R.4    Saoudi, A.5
  • 10
    • 84874515108 scopus 로고    scopus 로고
    • MAX1198, dual 8 bits, 105 Msps, low power ADC with parallel output
    • MAX1198, dual 8 bits, 105 Msps, low power ADC with parallel output, Maxim Integrated Products, www.maxim-ic.com.
    • Maxim Integrated Products


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.