메뉴 건너뛰기




Volumn 66, Issue 1, 2006, Pages 39-50

Bioimpedance analysis and intradialytic hypotension in intermittent hemodialysis

Author keywords

Acute renal failure; Blood pressure; Chronic renal failure; Extracellular water; Intraacellular water; Total Body water

Indexed keywords

ACUTE KIDNEY FAILURE; AGED; ARTICLE; BLOOD PRESSURE REGULATION; CHRONIC KIDNEY FAILURE; CLINICAL ARTICLE; CONTROLLED STUDY; CORRELATION ANALYSIS; DISEASE PREDISPOSITION; EXTRACELLULAR FLUID; EXTRACELLULAR SPACE; FEMALE; HEMODIALYSIS; HUMAN; HYPOTENSION; IMPEDANCE; INTRACELLULAR FLUID; MALE; MEAN ARTERIAL PRESSURE; PREDICTION; SEPTIC SHOCK; TOTAL BODY WATER;

EID: 33745913592     PISSN: 03010430     EISSN: None     Source Type: Journal    
DOI: 10.5414/cnp66039     Document Type: Article
Times cited : (10)

References (33)
  • 3
    • 0345258409 scopus 로고    scopus 로고
    • Volume control, blood pressure and cardiovascular function
    • Charra B, Chazot C. Volume control, blood pressure and cardiovascular function. Nephron Physiol. 2003; 93: 94-101.
    • (2003) Nephron Physiol. , vol.93 , pp. 94-101
    • Charra, B.1    Chazot, C.2
  • 4
    • 0033921109 scopus 로고    scopus 로고
    • Comparing different methods of assessing body composition in end-stage renal failure
    • Cooper BA, Aslani A, Ryan M et al. Comparing different methods of assessing body composition in end-stage renal failure. Kidney Int. 2000; 58: 408-416.
    • (2000) Kidney Int. , vol.58 , pp. 408-416
    • Cooper, B.A.1    Aslani, A.2    Ryan, M.3
  • 5
    • 0034780316 scopus 로고    scopus 로고
    • Pathophysiology of dialysis hypotension: An update
    • Daugirdas JT. Pathophysiology of dialysis hypotension: an update. Am J Kidney Dis. 2001; 38: 11-17.
    • (2001) Am J Kidney Dis. , vol.38 , pp. 11-17
    • Daugirdas, J.T.1
  • 7
    • 2542492371 scopus 로고    scopus 로고
    • A systematic evaluation of bioelectrical impedance measurement after hemodialysis session
    • Di Iorio BR, Scalfi R, Terracciano V, Bellizzi V. A systematic evaluation of bioelectrical impedance measurement after hemodialysis session. Kidney Int. 2004; 65: 2435-2440.
    • (2004) Kidney Int. , vol.65 , pp. 2435-2440
    • Di Iorio, B.R.1    Scalfi, R.2    Terracciano, V.3    Bellizzi, V.4
  • 8
    • 7044224645 scopus 로고    scopus 로고
    • Hemodialysis-induced hypotension: Impact of technologic advances
    • Donauer J. Hemodialysis-induced hypotension: Impact of technologic advances. Semin Dial. 2004; 17: 333-335.
    • (2004) Semin Dial. , vol.17 , pp. 333-335
    • Donauer, J.1
  • 9
    • 0038654192 scopus 로고    scopus 로고
    • Rationale for the use of blood volume and temperature control devices during hemodialysis
    • Donauer J, Böhler J. Rationale for the use of blood volume and temperature control devices during hemodialysis. Kidney Blood Press Res. 2003; 26: 82-89.
    • (2003) Kidney Blood Press Res , vol.26 , pp. 82-89
    • Donauer, J.1    Böhler, J.2
  • 10
    • 0043236390 scopus 로고    scopus 로고
    • Approach to intradialytic hypotension in intensive care unit patients with acute renal failure
    • Doshi M, Murray PT. Approach to intradialytic hypotension in intensive care unit patients with acute renal failure. Artif Organs. 2003; 27: 772-780.
    • (2003) Artif Organs , vol.27 , pp. 772-780
    • Doshi, M.1    Murray, P.T.2
  • 11
    • 11844271950 scopus 로고    scopus 로고
    • Prospective nutritional surveillance using bioelectrical impedance in chronic kidney disease patients
    • Dumler F, Kilates C. Prospective nutritional surveillance using bioelectrical impedance in chronic kidney disease patients. J Ren Nutr. 2005; 15: 148-151.
    • (2005) J Ren Nutr , vol.15 , pp. 148-151
    • Dumler, F.1    Kilates, C.2
  • 12
    • 0036238759 scopus 로고    scopus 로고
    • Reversibility of artefacts of fluid volume measurements by bioimpedance caused by position changes during dialysis
    • Fenech M, Jaffrin MY, Malmen U. Reversibility of artefacts of fluid volume measurements by bioimpedance caused by position changes during dialysis. Int J Artif Organs. 2002; 25: 21-22.
    • (2002) Int J Artif Organs , vol.25 , pp. 21-22
    • Fenech, M.1    Jaffrin, M.Y.2    Malmen, U.3
  • 13
    • 0036392792 scopus 로고    scopus 로고
    • Intermittend versus continuous renal replacement therapy for acute renal failure in intensive care units: Results from a multicenter prospective epidemiological survey
    • Guérin C, Girard R, Selli JM, Ayzac L. Intermittend versus continuous renal replacement therapy for acute renal failure in intensive care units: results from a multicenter prospective epidemiological survey. Int Care Med. 2002; 28: 1411-1418.
    • (2002) Int Care Med , vol.28 , pp. 1411-1418
    • Guérin, C.1    Girard, R.2    Selli, J.M.3    Ayzac, L.4
  • 14
    • 1642382811 scopus 로고    scopus 로고
    • Methods of assessment of volume status and intercompartmental fluid shifts in hemodialysis patients: Implications in clinical practice
    • Ishibe S, Paixoto AJ. Methods of assessment of volume status and intercompartmental fluid shifts in hemodialysis patients: implications in clinical practice. Semin Dial. 2004; 17: 37-43.
    • (2004) Semin Dial , vol.17 , pp. 37-43
    • Ishibe, S.1    Paixoto, A.J.2
  • 16
    • 0036698579 scopus 로고    scopus 로고
    • Age-related extracellular to total body water volume ratio (ECV/TBW) - Can it be used for "dry weight" determination in dialysis patients? Application of multifrequency bioimpedance measurement
    • Lopot F, Nejedly B, Novotna H, Mackova M, Sulkova S. Age-related extracellular to total body water volume ratio (ECV/TBW) - can it be used for "dry weight" determination in dialysis patients? Application of multifrequency bioimpedance measurement. Int J Axtif Organs. 2002; 25: 762-769.
    • (2002) Int J Axtif Organs , vol.25 , pp. 762-769
    • Lopot, F.1    Nejedly, B.2    Novotna, H.3    Mackova, M.4    Sulkova, S.5
  • 17
    • 1842418620 scopus 로고    scopus 로고
    • Sustained low-efficiency daily diafiltration (SLEDD-f) for critically ill patients requiring renal replacement therapy: Towards an adequate therapy
    • Marshall MR, Ma T, Galler D, Rankin APN, Williams AP. Sustained low-efficiency daily diafiltration (SLEDD-f) for critically ill patients requiring renal replacement therapy: towards an adequate therapy. Nephrol Dial Transplant. 2004; 19: 877-884.
    • (2004) Nephrol Dial Transplant , vol.19 , pp. 877-884
    • Marshall, M.R.1    Ma, T.2    Galler, D.3    Rankin, A.P.N.4    Williams, A.P.5
  • 18
    • 0036653211 scopus 로고    scopus 로고
    • Ultrafiltration and dialysate sodium profiling: Choosing the optimal therapy for your patients
    • Meers C. Ultrafiltration and dialysate sodium profiling: choosing the optimal therapy for your patients. CANNT J. 2002; 12: 33-46.
    • (2002) CANNT J , vol.12 , pp. 33-46
    • Meers, C.1
  • 19
    • 4344692876 scopus 로고    scopus 로고
    • Spectrum of acute renal failure in intensive care unit: The PICARD experience
    • For the Program to Improve Care in Acute Renal Diasease (PICARD)
    • Mehta RL, Pascual MT, Soroko S, Savage BR, Himmelfarb J, Ikizler TA, Paganini EP, Chertow GM, For the Program to Improve Care in Acute Renal Diasease (PICARD). Spectrum of acute renal failure in intensive care unit: The PICARD experience. Kidney Int. 2004; 66: 1613-1621.
    • (2004) Kidney Int , vol.66 , pp. 1613-1621
    • Mehta, R.L.1    Pascual, M.T.2    Soroko, S.3    Savage, B.R.4    Himmelfarb, J.5    Ikizler, T.A.6    Paganini, E.P.7    Chertow, G.M.8
  • 20
    • 17744365201 scopus 로고    scopus 로고
    • Validation of estimates of total body water in pediatric dialysis patients by deuterium dilution
    • Mendley SR, Majkowski NL, Schoeller DA. Validation of estimates of total body water in pediatric dialysis patients by deuterium dilution. Kidney Int. 2005; 67: 2056-2062.
    • (2005) Kidney Int , vol.67 , pp. 2056-2062
    • Mendley, S.R.1    Majkowski, N.L.2    Schoeller, D.A.3
  • 21
    • 0030025549 scopus 로고    scopus 로고
    • Prognostic factors in acute renal failure due to sepsis. Results of a prospective mulitcentre study
    • Neveu H, Kleinknecht D, Brivet F, Loirat P, Landais P. Prognostic factors in acute renal failure due to sepsis. Results of a prospective mulitcentre study. Nephrol Dial Transplant. 1996; 11: 293-299.
    • (1996) Nephrol Dial Transplant , vol.11 , pp. 293-299
    • Neveu, H.1    Kleinknecht, D.2    Brivet, F.3    Loirat, P.4    Landais, P.5
  • 22
    • 0031970239 scopus 로고    scopus 로고
    • Identification of operational clues dry weight prescription in hemodialysis using bioimpedance vector analysis
    • The Italian hemodialysis-bioelectrical impedance analysis (HD-BIA) study group
    • Piccoli A. Identification of operational clues dry weight prescription in hemodialysis using bioimpedance vector analysis. The Italian hemodialysis-bioelectrical impedance analysis (HD-BIA) study group. Kidney Int. 1998; 53: 1036-1043.
    • (1998) Kidney Int , vol.53 , pp. 1036-1043
    • Piccoli, A.1
  • 23
    • 11144298220 scopus 로고    scopus 로고
    • Equivalence of information from single versus multiple frequency bioimpedance vector analysis in hemodialysis
    • Piccoli A, Pastori G, Guizzo M, Rebeschini M, Naso A, Cascone C. Equivalence of information from single versus multiple frequency bioimpedance vector analysis in hemodialysis. Kidney Int. 2005; 67: 301-313.
    • (2005) Kidney Int , vol.67 , pp. 301-313
    • Piccoli, A.1    Pastori, G.2    Guizzo, M.3    Rebeschini, M.4    Naso, A.5    Cascone, C.6
  • 24
    • 0042311435 scopus 로고    scopus 로고
    • Blood pruification in the intensive care unit
    • Ponikvar R. Blood pruification in the intensive care unit. Nephrol Dial Transplant. 2003; 18: v63-v67.
    • (2003) Nephrol Dial Transplant , vol.18
    • Ponikvar, R.1
  • 25
    • 0028466182 scopus 로고
    • Plasma refilling during hemodailysis with decreasing ultrafiltration. Influence of dialysate sodium
    • Raja RM, Po Ci. Plasma refilling during hemodailysis with decreasing ultrafiltration. Influence of dialysate sodium. ASAIO J. 1994; 40: M423-424.
    • (1994) ASAIO J , vol.40
    • Raja, R.M.1    Po, Ci.2
  • 27
    • 4544236577 scopus 로고    scopus 로고
    • Daily hemodialysis in acute renal failure
    • Schiffl H. Daily hemodialysis in acute renal failure. Minerva Urol Nefrol. 2004; 56: 265-277.
    • (2004) Minerva Urol Nefrol , vol.56 , pp. 265-277
    • Schiffl, H.1
  • 28
    • 0036560874 scopus 로고    scopus 로고
    • Intradialytic hypotension: An overview of recent, unresolved and overlooked issues
    • Sherman RA. Intradialytic hypotension: an overview of recent, unresolved and overlooked issues. Semin Dial. 2002; 15: 141-143.
    • (2002) Semin Dial , vol.15 , pp. 141-143
    • Sherman, R.A.1
  • 29
    • 0036587331 scopus 로고    scopus 로고
    • Sodium and body fluid homeostasis in profiling hemodialysis treatment
    • Stefanidis I, Stiller S, Ikonomov V, Mann H. Sodium and body fluid homeostasis in profiling hemodialysis treatment. Int J Artif Organs. 2002; 25: 421-428.
    • (2002) Int J Artif Organs , vol.25 , pp. 421-428
    • Stefanidis, I.1    Stiller, S.2    Ikonomov, V.3    Mann, H.4
  • 30
    • 0036423321 scopus 로고    scopus 로고
    • Blood volume monitoring in intermittent hemodialysis for acute renal failure
    • Tonelli M, Astephen P, Andreou P, Beed S, Lundrigan P, Jindal K. Blood volume monitoring in intermittent hemodialysis for acute renal failure. Kidney Int. 2002; 62: 1075-1080.
    • (2002) Kidney Int , vol.62 , pp. 1075-1080
    • Tonelli, M.1    Astephen, P.2    Andreou, P.3    Beed, S.4    Lundrigan, P.5    Jindal, K.6
  • 32
    • 0344945400 scopus 로고    scopus 로고
    • Determination of urea distribution volume for Kt/V assessed by conductivity monitoring
    • Wuepper A, Tattersall J, Kraemer M, Wilkie M, Edwards L. Determination of urea distribution volume for Kt/V assessed by conductivity monitoring. Kidney Int. 2003; 64: 2262-2271.
    • (2003) Kidney Int , vol.64 , pp. 2262-2271
    • Wuepper, A.1    Tattersall, J.2    Kraemer, M.3    Wilkie, M.4    Edwards, L.5
  • 33
    • 0142026793 scopus 로고    scopus 로고
    • Comparison of prescribed and delivered dialysis dosing using anthropometrically and bioelectrically measured patient volumes
    • Zaluska WT, Schneditz D, Swatowski A, Jaroszynski A, Ksiazek A. Comparison of prescribed and delivered dialysis dosing using anthropometrically and bioelectrically measured patient volumes. Med Sci Monit. 2003; 9: CR 405-410.
    • (2003) Med Sci Monit , vol.9
    • Zaluska, W.T.1    Schneditz, D.2    Swatowski, A.3    Jaroszynski, A.4    Ksiazek, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.