메뉴 건너뛰기




Volumn 9, Issue 9, 2003, Pages

Comparison of prescribed and delivered doses of dialysis using anthropometrically and bioelectrically measured patient volumes

Author keywords

Dialysis; Total body water; Urea kinetic

Indexed keywords

ADULT; AGED; ANTHROPOMETRY; ARTICLE; DIALYSIS; DOSE RESPONSE; FEMALE; HUMAN; MAJOR CLINICAL STUDY; MALE; PRESCRIPTION; TOTAL BODY WATER; ULTRAFILTRATION; UREA BLOOD LEVEL;

EID: 0142026793     PISSN: 12341010     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (4)

References (22)
  • 1
    • 0028151616 scopus 로고
    • Role of dialysis dose on morbidity and mortality in maintenance hemodialysis patients
    • Parker TF: Role of dialysis dose on morbidity and mortality in maintenance hemodialysis patients. Am J Kidney Dis, 1994; 24: 981-989
    • (1994) Am J Kidney Dis , vol.24 , pp. 981-989
    • Parker, T.F.1
  • 2
    • 0026526464 scopus 로고
    • Inadequate dialysis increases gross mortality rate
    • Acchiardo SR, Hatten KW, Ruvinsky MJ et al: Inadequate dialysis increases gross mortality rate. ASAIO J, 1992; 38: 282-285
    • (1992) ASAIO J , vol.38 , pp. 282-285
    • Acchiardo, S.R.1    Hatten, K.W.2    Ruvinsky, M.J.3
  • 3
    • 0035221369 scopus 로고    scopus 로고
    • Clinical Practice Guidelines for Hemodialysis Adequacy: Update 2000
    • NKF-K/DOQI: Clinical Practice Guidelines for Hemodialysis Adequacy: update 2000. Am J Kidney Dis, 2001; 37(suppl. 1): 7-64
    • (2001) Am J Kidney Dis , vol.37 , Issue.SUPPL. 1 , pp. 7-64
  • 4
    • 0021783946 scopus 로고
    • A mechanistic analysis of the National Cooperative Dialysis Study (NCDS)
    • Gotch FA, Sargent JA: A mechanistic analysis of the National Cooperative Dialysis Study (NCDS). Kidney Int, 1985; 28: 526-34
    • (1985) Kidney Int , vol.28 , pp. 526-534
    • Gotch, F.A.1    Sargent, J.A.2
  • 6
    • 0026468057 scopus 로고
    • Cardiopulmonary recirculation during hemodialysis
    • Schneditz D, Kaufman AM, Polaschegg HD et al: Cardiopulmonary recirculation during hemodialysis. Kidney Int, 1992; 42: 1450-1456
    • (1992) Kidney Int , vol.42 , pp. 1450-1456
    • Schneditz, D.1    Kaufman, A.M.2    Polaschegg, H.D.3
  • 7
    • 0018864615 scopus 로고
    • Total body water volumes for adult males and females estimated from simple anthropometric measurements
    • Watson PE, Watson ID, Batt RD: Total body water volumes for adult males and females estimated from simple anthropometric measurements. Am J Clin Nutr, 1980; 33: 27-39
    • (1980) Am J Clin Nutr , vol.33 , pp. 27-39
    • Watson, P.E.1    Watson, I.D.2    Batt, R.D.3
  • 8
    • 0028139354 scopus 로고
    • Bioimpedance analysis of total body water in hemodialysis patients
    • Ho TL, Kuschner RF, Schoeler DA et al: Bioimpedance analysis of total body water in hemodialysis patients. Kidney Int, 1994; 46: 1438-1442
    • (1994) Kidney Int , vol.46 , pp. 1438-1442
    • Ho, T.L.1    Kuschner, R.F.2    Schoeler, D.A.3
  • 9
    • 0028807127 scopus 로고
    • Multifrequency bioelectrical impedance estimates the distribution of body water
    • Cha K, Chertow GM, Gonzalez J et al: Multifrequency bioelectrical impedance estimates the distribution of body water. J Appl Physiol, 1995; 79: 1316-1319
    • (1995) J Appl Physiol , vol.79 , pp. 1316-1319
    • Cha, K.1    Chertow, G.M.2    Gonzalez, J.3
  • 10
    • 0031905911 scopus 로고    scopus 로고
    • Variation in blood sample collection for determination of hemodialysis adequacy
    • For the Council on Renal Nutrition National Research Question Collaborative Study Group
    • Beto JA, Bansal VK, Ing TS, Daugirdas JT: For the Council on Renal Nutrition National Research Question Collaborative Study Group: Variation in blood sample collection for determination of hemodialysis adequacy. Am J Kidney Dis, 1998; 31: 135-41
    • (1998) Am J Kidney Dis , vol.31 , pp. 135-141
    • Beto, J.A.1    Bansal, V.K.2    Ing, T.S.3    Daugirdas, J.T.4
  • 11
    • 0032213550 scopus 로고    scopus 로고
    • Relative understimation of fluid removal during hemodialysis hypotension measured by wrist to ankle bioimpedance
    • Zaluska WT, Schneditz D, Kaufman AM et al: Relative understimation of fluid removal during hemodialysis hypotension measured by wrist to ankle bioimpedance. ASAIO J, 1998; 44: 823-27
    • (1998) ASAIO J , vol.44 , pp. 823-827
    • Zaluska, W.T.1    Schneditz, D.2    Kaufman, A.M.3
  • 12
    • 0030978220 scopus 로고    scopus 로고
    • Effects of postural changes on the reliability of volume estimations from bioimpedance spectroscopy data
    • Scharfetter H, Monif M, Laszlo Z et al: Effects of postural changes on the reliability of volume estimations from bioimpedance spectroscopy data. Kidney Int, 1997; 51: 1078-87
    • (1997) Kidney Int , vol.51 , pp. 1078-1087
    • Scharfetter, H.1    Monif, M.2    Laszlo, Z.3
  • 13
    • 0036113534 scopus 로고    scopus 로고
    • A new technique for establishing dry weight in hemodialysis patients via whole body bioimpedance
    • Chamney PW, Krämer M, Rode C et al: A new technique for establishing dry weight in hemodialysis patients via whole body bioimpedance. Kidney Int. 2002; 61: 2250-2258
    • (2002) Kidney Int , vol.61 , pp. 2250-2258
    • Chamney, P.W.1    Krämer, M.2    Rode, C.3
  • 14
    • 0029903408 scopus 로고    scopus 로고
    • The post-hemodialysis rebound: Predicting and quantifying its effect on Kt/V
    • Tattersall JE, De Takats D, Chamney PW et al: The post-hemodialysis rebound: predicting and quantifying its effect on Kt/V. Kidney Int, 1996; 50: 2094-102
    • (1996) Kidney Int , vol.50 , pp. 2094-2102
    • Tattersall, J.E.1    De Takats, D.2    Chamney, P.W.3
  • 16
    • 0027688501 scopus 로고
    • Second generation logarithmic estimates of single-pool variable volume Kt/V: An analysis of error
    • Daugirdas JT: Second generation logarithmic estimates of single-pool variable volume Kt/V: an analysis of error. J Am Soc Nephrol, 1993; 4: 1205-1213
    • (1993) J Am Soc Nephrol , vol.4 , pp. 1205-1213
    • Daugirdas, J.T.1
  • 18
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet, 1986; 1: 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 19
    • 0028338537 scopus 로고
    • Segmental bioelectrical impedance analysis: Theory and application of a new technique
    • Organ LW, Bradham GB, Gore DT, Lozier SL: Segmental bioelectrical impedance analysis: theory and application of a new technique. J Appl Physiol, 1994; 77: 98-112
    • (1994) J Appl Physiol , vol.77 , pp. 98-112
    • Organ, L.W.1    Bradham, G.B.2    Gore, D.T.3    Lozier, S.L.4
  • 20
    • 0031928649 scopus 로고    scopus 로고
    • Dynamics of segmental extracellular volumes during changes in body position by bioimpedance analysis
    • Zhu F, Schneditz D, Wang E, Levin NW: Dynamics of segmental extracellular volumes during changes in body position by bioimpedance analysis. J Appl Physiol, 1998; 85: 497-504
    • (1998) J Appl Physiol , vol.85 , pp. 497-504
    • Zhu, F.1    Schneditz, D.2    Wang, E.3    Levin, N.W.4
  • 21
    • 0032807622 scopus 로고    scopus 로고
    • Sum of segmental bioimpedance analysis during ultrafiltration and hemodialysis: A new technique with reduced sensitivity to changes body position
    • Zhu F, Schneditz D, Levin NW: Sum of segmental bioimpedance analysis during ultrafiltration and hemodialysis: A new technique with reduced sensitivity to changes body position. Kidney Int, 1999; 56: 692-699
    • (1999) Kidney Int , vol.56 , pp. 692-699
    • Zhu, F.1    Schneditz, D.2    Levin, N.W.3
  • 22
    • 0033010503 scopus 로고    scopus 로고
    • Monitoring dialysis efficacy by comparing delivered and predicted Kt/V
    • Beige J, Sharma AM, Distler A et al: Monitoring dialysis efficacy by comparing delivered and predicted Kt/V. Nephrol Dial Transplant. 1999; 14: 683-687
    • (1999) Nephrol Dial Transplant , vol.14 , pp. 683-687
    • Beige, J.1    Sharma, A.M.2    Distler, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.