Volumn 6142 II, Issue , 2006, Pages

Monte Carlo simulation of x-ray scatter based on patient model from digital breast tomosynthesis

Author keywords

Digital mammography; Monte Carlo simulation; Scatter correction; Tomosynthesis

Indexed keywords

DIGITAL BREAST TOMOSYNTHESIS; DIGITAL MAMMOGRAPHY; GE (CO); SCATTER CORRECTION; TOMOSYNTHESIS;

EID: 33745421470     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.650193     Document Type: Conference Paper
Times cited : (21)

References (15)
  • 1
    • 27344458270 scopus 로고    scopus 로고
    • Diagnostic performance of digital versus film mammography for breast-cancer screening
    • E.D. Pisano et al, Diagnostic performance of digital versus film mammography for breast-cancer screening. N Engl J Med., 353:1773-83, 2005.
    • (2005) N Engl J Med. , vol.353 , pp. 1773-1783
    • Pisano, E.D.1
  • 2
    • 0023916542 scopus 로고
    • Decreased breast cancer mortality through mammographic screening: Results of clinical trial
    • S.A. Feig, "Decreased Breast Cancer Mortality Through Mammographic Screening: Results of Clinical Trial," Radiology, 167, 659-665, 1988.
    • (1988) Radiology , vol.167 , pp. 659-665
    • Feig, S.A.1
  • 3
    • 0035190741 scopus 로고    scopus 로고
    • Dedicated breast CT: Radiation dose and image quality evaluation
    • Boone JM, Nelson TR, Lindfors KK, Seibert JA. Dedicated breast CT: radiation dose and image quality evaluation, Radiology. 2001, 221, 657-67
    • (2001) Radiology , vol.221 , pp. 657-667
    • Boone, J.M.1    Nelson, T.R.2    Lindfors, K.K.3    Seibert, J.A.4
  • 4
    • 0035999405 scopus 로고    scopus 로고
    • Cone-beam volume CT breast imaging: Feasibility study
    • R. Ning et al, "Cone-beam volume CT breast imaging: Feasibility study," Med. Phys. 29, 755-770, 2001.
    • (2001) Med. Phys. , vol.29 , pp. 755-770
    • Ning, R.1
  • 5
    • 0030711575 scopus 로고    scopus 로고
    • Digital Tomosynthesis in breast imaging
    • L. T. Niklason et al, "Digital Tomosynthesis in breast imaging," Radiology 205, 399-405, 1997
    • (1997) Radiology , vol.205 , pp. 399-405
    • Niklason, L.T.1
  • 6
    • 0037339682 scopus 로고    scopus 로고
    • Tomographic mammography using a limited number of low-dose cone-beam projection images
    • T. Wu, J. Zhang, R. Moore, E. Rafferty, D. Kopans, W. Meleis, and D. Kaeli, "Tomographic mammography using a limited number of low-dose cone-beam projection images," Med. Phys. 30, 365, 2003.
    • (2003) Med. Phys. , vol.30 , pp. 365
    • Wu, T.1    Zhang, J.2    Moore, R.3    Rafferty, E.4    Kopans, D.5    Meleis, W.6    Kaeli, D.7
  • 7
    • 27544436222 scopus 로고    scopus 로고
    • Mammographic breast density and the gail model for breast cancer risk prediction in a screening population
    • J. A. Tice, S. R. Cummings, E. Ziv, K. Kerlikowske, Mammographic breast density and the gail model for breast cancer risk prediction in a screening population, Breast Cancer Res Treat., 94, 115-122, 2005.
    • (2005) Breast Cancer Res Treat. , vol.94 , pp. 115-122
    • Tice, J.A.1    Cummings, S.R.2    Ziv, E.3    Kerlikowske, K.4
  • 8
    • 0141928682 scopus 로고    scopus 로고
    • Digital x-ray tomosynthesis: Current state of the art and clinical potential
    • T.J. Dobbins, D.J. Godfrey, Digital x-ray tomosynthesis: current state of the art and clinical potential. Phys Med Biol. 48, R65-106, 2003
    • (2003) Phys Med Biol. , vol.48
    • Dobbins, T.J.1    Godfrey, D.J.2
  • 9
    • 0033735247 scopus 로고    scopus 로고
    • Scatter/primary in mammography: Comprehensive results
    • J.M. Boone, K.K. Lindfors , V.N. Cooper, J. A. Seibert, Scatter/primary in mammography: comprehensive results. Med Phys. 10, 2408-16, 2000
    • (2000) Med Phys. , vol.10 , pp. 2408-2416
    • Boone, J.M.1    Lindfors, K.K.2    Cooper, V.N.3    Seibert, J.A.4
  • 10
    • 3042561412 scopus 로고
    • The deveoplement and use of realistically-shaped , Tissue equivalent phantom for assessing the mammographi process
    • P. F. Fatouros, S. Skubic, The deveoplement and Use of Realistically-shaped , Tissue Equivalent Phantom for Assessing the Mammographi Process, Radiology, 157, P32, 1985.
    • (1985) Radiology , vol.157
    • Fatouros, P.F.1    Skubic, S.2
  • 11
    • 5744251917 scopus 로고    scopus 로고
    • GATE: A simulation toolkit for PET and SPECT
    • S. Jan et al., GATE: a simulation toolkit for PET and SPECT, Phys Med Biol., 49, 4543-61, 2004.
    • (2004) Phys Med Biol. , vol.49 , pp. 4543-4561
    • Jan, S.1
  • 12
    • 31044439395 scopus 로고    scopus 로고
    • Validation of GATE Monte Carlo simulations of the GE advance/discovery LS PET scanners
    • C.S. Schmidtlein et al., Validation of GATE Monte Carlo simulations of the GE Advance/Discovery LS PET scanners, Med. Phys. 33, 198-208, 2006
    • (2006) Med. Phys. , vol.33 , pp. 198-208
    • Schmidtlein, C.S.1
  • 13
    • 0031466296 scopus 로고    scopus 로고
    • Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography
    • J. M. Boone, T. R. Fewell, and R. J. Jennings, Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography, Med. Phys. 24, 1863-1874, 1997.
    • (1997) Med. Phys. , vol.24 , pp. 1863-1874
    • Boone, J.M.1    Fewell, T.R.2    Jennings, R.J.3
  • 14
    • 84858888598 scopus 로고    scopus 로고
    • http://root.cern.ch/


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.