메뉴 건너뛰기




Volumn 41, Issue 1, 2006, Pages 391-399

Progress on the accelerator based SPES-BNCT project at INFN Legnaro

Author keywords

[No Author keywords available]

Indexed keywords


EID: 33745318873     PISSN: 17426588     EISSN: 17426596     Source Type: Conference Proceeding    
DOI: 10.1088/1742-6596/41/1/043     Document Type: Conference Paper
Times cited : (12)

References (19)
  • 1
    • 33745313660 scopus 로고    scopus 로고
    • SPES Technical design report A Bracco and A Pisent editors LNL-INFN(REP) 181/2002 http://www.lnl.infn.it/∼spes/
    • SPES Technical Design Report
  • 3
    • 33745323362 scopus 로고    scopus 로고
    • Pisent A, et al TRASCO RFQ Proc. XXI Int. Linac Conf., Monterey, California, August 21 - 25, 2000
    • TRASCO RFQ
    • Pisent, A.1
  • 6
    • 33745309856 scopus 로고
    • The TERA Project and the Centre for Oncological Hadrontherapy
    • Amaldi U, Silari M, Eds
    • Amaldi U, Silari M, Eds 1995 The TERA Project and the Centre for Oncological Hadrontherapy INFN-LNF Frascati (Roma) 2nd edn ed Amaldi U, Silari M
    • (1995) INFN-LNF Frascati (Roma)
  • 7
    • 0007097221 scopus 로고    scopus 로고
    • An accelerator-based thermal neutron source for BNCT
    • Agosteo S, et al 1997 An accelerator-based thermal neutron source for BNCT Advances in Neutron Capture Therapy vol 1 p 483-489
    • (1997) Advances in Neutron Capture Therapy , vol.1 , pp. 483-489
    • Agosteo, S.1
  • 8
    • 0030980544 scopus 로고    scopus 로고
    • Characterization of an accelerator- based neutron source for BNCT of explanted livers
    • Agosteo S, et al 1997 Characterization of an accelerator- based neutron source for BNCT of explanted livers Radiat. Prot. Dos. 70 559-566
    • (1997) Radiat. Prot. Dos. , vol.70 , Issue.1-4 , pp. 559-566
    • Agosteo, S.1
  • 11
    • 0021713280 scopus 로고
    • Ionisation distributions and A-150 plastik kerma for neutrons between 13.9 and 19.0 MeV measured with a low pressure proportional counter
    • Menzel HG, et al 1994 Ionisation distributions and A-150 plastik kerma for neutrons between 13.9 and 19.0 MeV measured with a low pressure proportional counter Phys. Med. Biol. 29 1537-1554
    • (1994) Phys. Med. Biol. , vol.29 , pp. 1537-1554
    • Menzel, H.G.1
  • 12
    • 0023640522 scopus 로고
    • Dosimetry of low-energy neutrons using low-pressure proportional counters
    • Schuhmacher H, et al 1987 Dosimetry of low-energy neutrons using low-pressure proportional counters Radiation Research vol 111 p 1-13
    • (1987) Radiation Research , vol.111 , pp. 1-13
    • Schuhmacher, H.1
  • 13
    • 0031852203 scopus 로고    scopus 로고
    • Microdosimetric Measurements in the Fast Neutron Therapeutic Beam of Nice
    • Colautti P, et al 1998 Microdosimetric Measurements in the Fast Neutron Therapeutic Beam of Nice Physica Medica 14 55-62
    • (1998) Physica Medica , vol.14 , Issue.2 , pp. 55-62
    • Colautti, P.1
  • 14
    • 0037150007 scopus 로고    scopus 로고
    • Characterisation of miniature tissue-equivalent proportional counters for neutron radiotherapy applications
    • Burmeister J, et al 2002 Characterisation of miniature tissue-equivalent proportional counters for neutron radiotherapy applications Phys. Med. Biol. 47 1633-1645
    • (2002) Phys. Med. Biol. , vol.47 , Issue.10 , pp. 1633-1645
    • Burmeister, J.1
  • 15
    • 0034806317 scopus 로고    scopus 로고
    • Miniature tissue-equivalent proportional counters for BNCT and BNCEFNT
    • Burmeister J, et al 2001 Miniature tissue-equivalent proportional counters for BNCT and BNCEFNT Medical Phys. 28 1911-1925
    • (2001) Medical Phys. , vol.28 , Issue.9 , pp. 1911-1925
    • Burmeister, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.