메뉴 건너뛰기




Volumn 25, Issue 1, 2006, Pages 154-160

Corrosion resistance and surface characterization of electrolyzed Ti-Ni alloy

Author keywords

Electrolytic treatment; Surface characterization; Ti Ni alloy

Indexed keywords

NICKEL; TITANIUM; TITANIUM NICKELIDE;

EID: 33745285697     PISSN: 02874547     EISSN: None     Source Type: Journal    
DOI: 10.4012/dmj.25.151     Document Type: Article
Times cited : (28)

References (50)
  • 1
    • 0027024186 scopus 로고
    • Influence of composition and purity on tensile properties of Ni-Ti alloy castings
    • Yoneyama T, Doi H, Hamanaka H. Influence of composition and purity on tensile properties of Ni-Ti alloy castings. Dent Mater J 1992; 11: 157-164.
    • (1992) Dent Mater J , vol.11 , pp. 157-164
    • Yoneyama, T.1    Doi, H.2    Hamanaka, H.3
  • 2
    • 0030310863 scopus 로고    scopus 로고
    • Titanium in dentistry: Development and research in the USA
    • Nakajima H, Okabe T. Titanium in dentistry: Development and research in the USA. Dent Mater J 1996; 15: 77-90.
    • (1996) Dent Mater J , vol.15 , pp. 77-90
    • Nakajima, H.1    Okabe, T.2
  • 3
    • 0036796484 scopus 로고    scopus 로고
    • Effect of heat treatment with the mould on the super-elastic property of Ti-Ni alloy castings for dental application
    • Yoneyama T, Doi H, Kobayashi E, Hamanaka H. Effect of heat treatment with the mould on the super-elastic property of Ti-Ni alloy castings for dental application. J Mater Sci: Mater Med 2002; 13: 947-951.
    • (2002) J Mater Sci: Mater Med , vol.13 , pp. 947-951
    • Yoneyama, T.1    Doi, H.2    Kobayashi, E.3    Hamanaka, H.4
  • 4
  • 6
    • 0031801887 scopus 로고    scopus 로고
    • Hemispheric titanium porous coated acetabular component without screw fixation
    • Dorr LD, Wan ZN, Cohen J. Hemispheric titanium porous coated acetabular component without screw fixation. Clin Orthop Relat R 1998; 351: 158-168.
    • (1998) Clin Orthop Relat R , vol.351 , pp. 158-168
    • Dorr, L.D.1    Wan, Z.N.2    Cohen, J.3
  • 7
    • 0032190924 scopus 로고    scopus 로고
    • Mechanical properties and corrosion resistance of Ti-6Al-7Nb alloy dental castings
    • Kobayashi E, Wang TJ, Doi H, Yoneyama T, Hamanaka H. Mechanical properties and corrosion resistance of Ti-6Al-7Nb alloy dental castings. J Mater Sci: Mater Med 1998; 9: 567-574.
    • (1998) J Mater Sci: Mater Med , vol.9 , pp. 567-574
    • Kobayashi, E.1    Wang, T.J.2    Doi, H.3    Yoneyama, T.4    Hamanaka, H.5
  • 8
    • 0035288644 scopus 로고    scopus 로고
    • Microstructure and corrosion behavior of binary titanium alloys with beta-stabilizing elements
    • Takada Y, Nakajima H, Okuno O, Okabe T. Microstructure and corrosion behavior of binary titanium alloys with beta-stabilizing elements. Dent Mater J 2001; 20: 34-52.
    • (2001) Dent Mater J , vol.20 , pp. 34-52
    • Takada, Y.1    Nakajima, H.2    Okuno, O.3    Okabe, T.4
  • 9
    • 0035757573 scopus 로고    scopus 로고
    • Corrosion behavior of pure titanium and titanium alloys in fluoride-containing solutions
    • Nakagawa M, Matsuya S, Udoh K. Corrosion behavior of pure titanium and titanium alloys in fluoride-containing solutions. Dent Mater J 2001; 20: 305-314.
    • (2001) Dent Mater J , vol.20 , pp. 305-314
    • Nakagawa, M.1    Matsuya, S.2    Udoh, K.3
  • 10
    • 0036617834 scopus 로고    scopus 로고
    • Effects of fluoride and dissolved oxygen concentrations on the corrosion behavior of pure titanium and titanium alloys
    • Nakagawa M, Matsuya S, Udoh K. Effects of fluoride and dissolved oxygen concentrations on the corrosion behavior of pure titanium and titanium alloys. Dent Mater J 2002; 21: 83-92.
    • (2002) Dent Mater J , vol.21 , pp. 83-92
    • Nakagawa, M.1    Matsuya, S.2    Udoh, K.3
  • 11
    • 4344592360 scopus 로고    scopus 로고
    • Corrosion behavior and microstructures of experimental Ti-Au alloys
    • Takahashi M, Kikuchi M, Takada Y, Okuno O, Okabe T. Corrosion behavior and microstructures of experimental Ti-Au alloys. Dent Mater J 2004; 23: 109-116.
    • (2004) Dent Mater J , vol.23 , pp. 109-116
    • Takahashi, M.1    Kikuchi, M.2    Takada, Y.3    Okuno, O.4    Okabe, T.5
  • 12
    • 4344607831 scopus 로고    scopus 로고
    • In vitro corrosion characteristics of commercially available orthodontic wires
    • Yonekura Y, Endo K, Iijima M, Ohno H, Mizoguchi I. In vitro corrosion characteristics of commercially available orthodontic wires. Dent Mater J 2004; 23: 197-202.
    • (2004) Dent Mater J , vol.23 , pp. 197-202
    • Yonekura, Y.1    Endo, K.2    Iijima, M.3    Ohno, H.4    Mizoguchi, I.5
  • 13
    • 10044252142 scopus 로고    scopus 로고
    • Corrosion behavior and surface characterization of Ti-20Cr alloy in a solution containing fluoride
    • Takemoto S, Hattori M, Yoshinari M, Kawada E, Asami K, Oda Y. Corrosion behavior and surface characterization of Ti-20Cr alloy in a solution containing fluoride. Dent Mater J 2004; 23: 379-386.
    • (2004) Dent Mater J , vol.23 , pp. 379-386
    • Takemoto, S.1    Hattori, M.2    Yoshinari, M.3    Kawada, E.4    Asami, K.5    Oda, Y.6
  • 14
    • 23944482902 scopus 로고    scopus 로고
    • Electrochemical properties and released ions of Au-1.6mass%Ti alloy
    • Takada Y, Ito M, Kimura K, Okuno O. Electrochemical properties and released ions of Au-1.6mass%Ti alloy. Dent Mater J 2005; 24: 153-162.
    • (2005) Dent Mater J , vol.24 , pp. 153-162
    • Takada, Y.1    Ito, M.2    Kimura, K.3    Okuno, O.4
  • 16
    • 0022747571 scopus 로고
    • The super-elastic property of the Japanese NiTi alloy wire for use in orthodontics
    • Miura F, Mogi M, Ohura Y, Hamanaka H. The super-elastic property of the Japanese NiTi alloy wire for use in orthodontics. Am J Orthod Dentfac Orthop 1986; 90: 1-10.
    • (1986) Am J Orthod Dentfac Orthop , vol.90 , pp. 1-10
    • Miura, F.1    Mogi, M.2    Ohura, Y.3    Hamanaka, H.4
  • 17
  • 18
    • 0024052338 scopus 로고
    • An initial investigation of the bending and torsional properties of nitinol root canal files
    • Walia HM, Brantley WA, Gerstein H. An initial investigation of the bending and torsional properties of nitinol root canal files. J Endodont 1988; 14: 346-351.
    • (1988) J Endodont , vol.14 , pp. 346-351
    • Walia, H.M.1    Brantley, W.A.2    Gerstein, H.3
  • 19
    • 0032777189 scopus 로고    scopus 로고
    • Continued expansion of the nitinol self-expanding coronary stent: Angiographic analysis and 1-year clinical follow-up
    • Roguin A, Grenadier E, Linn S, Markiewicz W, Beyar R. Continued expansion of the nitinol self-expanding coronary stent: Angiographic analysis and 1-year clinical follow-up. Am Heart J 1999; 138: 326-333.
    • (1999) Am Heart J , vol.138 , pp. 326-333
    • Roguin, A.1    Grenadier, E.2    Linn, S.3    Markiewicz, W.4    Beyar, R.5
  • 21
    • 0028704565 scopus 로고
    • Effects of titanium nitride coatings on surface and corrosion characteristics of Ni-Ti alloy
    • Endo K, Sachdeva R, Araki Y, Ohno H. Effects of titanium nitride coatings on surface and corrosion characteristics of Ni-Ti alloy. Dent Mater J 1994; 13: 228-239.
    • (1994) Dent Mater J , vol.13 , pp. 228-239
    • Endo, K.1    Sachdeva, R.2    Araki, Y.3    Ohno, H.4
  • 22
    • 0029421268 scopus 로고
    • Chemical modification of metallic implant surfaces with biofunctional proteins. Part 2: Corrosion resistance of a chemically modified NiTi alloy
    • Endo K. Chemical modification of metallic implant surfaces with biofunctional proteins. Part 2: Corrosion resistance of a chemically modified NiTi alloy. Dent Mater J 1995; 14: 199-210.
    • (1995) Dent Mater J , vol.14 , pp. 199-210
    • Endo, K.1
  • 23
    • 0032018066 scopus 로고    scopus 로고
    • Effect of Cr and Cu addition on corrosion behavior of Ni-Ti alloys
    • Iijima M, Endo K, Ohno H, Mizoguchi I. Effect of Cr and Cu addition on corrosion behavior of Ni-Ti alloys. Dent Mater J 1998; 17: 31-40.
    • (1998) Dent Mater J , vol.17 , pp. 31-40
    • Iijima, M.1    Endo, K.2    Ohno, H.3    Mizoguchi, I.4
  • 24
    • 0035288675 scopus 로고    scopus 로고
    • Corrosion behavior and surface structure of orthodontic Ni-Ti alloy wires
    • Iijima M, Endo K, Ohno H, Yonekura Y, Mizoguchi I. Corrosion behavior and surface structure of orthodontic Ni-Ti alloy wires. Dent Mater J 2001; 20: 103-113.
    • (2001) Dent Mater J , vol.20 , pp. 103-113
    • Iijima, M.1    Endo, K.2    Ohno, H.3    Yonekura, Y.4    Mizoguchi, I.5
  • 25
    • 0004418238 scopus 로고
    • Released metallic ions from Ti, Ti-6Al-4V alloy and Ni-Ti alloy
    • Yoneyama T, Doi H, Kobayashi E, Hamanaka H. Released metallic ions from Ti, Ti-6Al-4V alloy and Ni-Ti alloy. J Jpn Soc Biomater 1993; 11: 71-81.
    • (1993) J Jpn Soc Biomater , vol.11 , pp. 71-81
    • Yoneyama, T.1    Doi, H.2    Kobayashi, E.3    Hamanaka, H.4
  • 26
    • 0030298058 scopus 로고    scopus 로고
    • In vitro corrosion and wear of titanium alloys in the biological environment
    • Khan MA, Williams RL, Williams DF. In vitro corrosion and wear of titanium alloys in the biological environment. Biomaterials 1996; 17: 2117-2126.
    • (1996) Biomaterials , vol.17 , pp. 2117-2126
    • Khan, M.A.1    Williams, R.L.2    Williams, D.F.3
  • 28
    • 0030200245 scopus 로고    scopus 로고
    • Interactions of orthopaedic metals with an immortalized rat osteoblast cell line
    • McKay GC, Macnair R, MacDonald C, Grant MH. Interactions of orthopaedic metals with an immortalized rat osteoblast cell line. Biomaterials 1996; 17: 1339-1344.
    • (1996) Biomaterials , vol.17 , pp. 1339-1344
    • McKay, G.C.1    Macnair, R.2    MacDonald, C.3    Grant, M.H.4
  • 29
    • 0030019934 scopus 로고    scopus 로고
    • Nickel-containing alloys and platings and their ability to cause dermatitis
    • Lidén C, Menné T, Burrows D. Nickel-containing alloys and platings and their ability to cause dermatitis. Brit J Dermatol 1996; 134: 193-198.
    • (1996) Brit J Dermatol , vol.134 , pp. 193-198
    • Lidén, C.1    Menné, T.2    Burrows, D.3
  • 31
    • 0036118827 scopus 로고    scopus 로고
    • Nickel essentiality, toxicity, and carcinogenicity
    • Denkhaus E, Salnikow K. Nickel essentiality, toxicity, and carcinogenicity. Crit Rev Oncol Hemat 2002; 42: 35-56.
    • (2002) Crit Rev Oncol Hemat , vol.42 , pp. 35-56
    • Denkhaus, E.1    Salnikow, K.2
  • 33
    • 0032090001 scopus 로고    scopus 로고
    • Effects of surface treatment on the surface chemistry of NiTi alloy for biomedical applications
    • Trigwell S, Hayden RD, Nelson KF, Selvaduray G. Effects of surface treatment on the surface chemistry of NiTi alloy for biomedical applications. Surf Interface Anal 1998; 26: 483-489.
    • (1998) Surf Interface Anal , vol.26 , pp. 483-489
    • Trigwell, S.1    Hayden, R.D.2    Nelson, K.F.3    Selvaduray, G.4
  • 34
    • 15744368004 scopus 로고    scopus 로고
    • Nature of oxide layer formed on NiTi by anodic oxidation in methanol
    • Cheng FT, Shi P, Man HC. Nature of oxide layer formed on NiTi by anodic oxidation in methanol. Mater Lett 2005; 59: 1516-1520.
    • (2005) Mater Lett , vol.59 , pp. 1516-1520
    • Cheng, F.T.1    Shi, P.2    Man, H.C.3
  • 35
    • 0026816818 scopus 로고
    • Formation and characterization of anodized layers on CP Ti and Ti-6Al-4V biomaterials
    • Dunn D, Raghavan S. Formation and characterization of anodized layers on CP Ti and Ti-6Al-4V biomaterials. Surf Coat Tech 1992; 50: 223-232.
    • (1992) Surf Coat Tech , vol.50 , pp. 223-232
    • Dunn, D.1    Raghavan, S.2
  • 36
    • 0032165506 scopus 로고    scopus 로고
    • Surface finishing of high speed print bonds. Part II: An electrochemical process for microfinishing of hardened Fe-13Cr stainless steel
    • Datta M, Romankiw LT. Surface finishing of high speed print bonds. Part II: An electrochemical process for microfinishing of hardened Fe-13Cr stainless steel. J Electrochem Soc 1998; 145: 3052-3057.
    • (1998) J Electrochem Soc , vol.145 , pp. 3052-3057
    • Datta, M.1    Romankiw, L.T.2
  • 40
    • 0042883776 scopus 로고
    • A precisely consistent energy calibration method for X-ray photoelectron spectroscopy
    • Asami K. A precisely consistent energy calibration method for X-ray photoelectron spectroscopy. J Electron Spectrosc 1976; 9: 469-478.
    • (1976) J Electron Spectrosc , vol.9 , pp. 469-478
    • Asami, K.1
  • 41
    • 0017632531 scopus 로고
    • XPS determination of composition of alloy surfaces and surface oxides on mechanically polished iron-chromium alloys
    • Asami K, Hashimoto K, Shimodaira S. XPS determination of composition of alloy surfaces and surface oxides on mechanically polished iron-chromium alloys. Corros Sci 1977; 17: 713-723.
    • (1977) Corros Sci , vol.17 , pp. 713-723
    • Asami, K.1    Hashimoto, K.2    Shimodaira, S.3
  • 42
    • 0021196683 scopus 로고
    • An XPS study of the surfaces on Fe-Cr, Fe-Co and Fe-Ni alloys after mechanical polishing
    • Asami K, Hashimoto K. An XPS study of the surfaces on Fe-Cr, Fe-Co and Fe-Ni alloys after mechanical polishing. Corros Sci 1984; 24: 83-97.
    • (1984) Corros Sci , vol.24 , pp. 83-97
    • Asami, K.1    Hashimoto, K.2
  • 43
    • 0027807808 scopus 로고
    • The surface characterization of titanium and titanium-nickel alloys in sulfuric acid
    • Asami K, Chen SC, Habasaki H, Hashimoto K. The surface characterization of titanium and titanium-nickel alloys in sulfuric acid. Corros Sci 1993; 35: 43-49.
    • (1993) Corros Sci , vol.35 , pp. 43-49
    • Asami, K.1    Chen, S.C.2    Habasaki, H.3    Hashimoto, K.4
  • 46
    • 0442306327 scopus 로고
    • Japan Technical Information Service, Tokyo
    • Sato N. Denkyoku kagaku, 1st ed, Japan Technical Information Service, Tokyo, 1994, pp.337-471.
    • (1994) Denkyoku Kagaku, 1st Ed. , pp. 337-471
    • Sato, N.1
  • 49
    • 0032527072 scopus 로고    scopus 로고
    • Repassivation of titanium and surface oxide film regenerated in simulated bioliquid
    • Hanawa T, Asami K, Asaoka K. Repassivation of titanium and surface oxide film regenerated in simulated bioliquid. J Biomed Mater Res 1998; 40: 530-538.
    • (1998) J Biomed Mater Res , vol.40 , pp. 530-538
    • Hanawa, T.1    Asami, K.2    Asaoka, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.