메뉴 건너뛰기




Volumn 32, Issue 7, 2006, Pages 675-679

SEM Observations and Differential Scanning Calorimetric Studies of New and Sterilized Nickel-Titanium Rotary Endodontic Instruments

Author keywords

DSC; Flexmaster; Nickel titanium endodontic instruments; ProFile; sterilization

Indexed keywords

AUSTENITE; DENTAL ALLOY; MARTENSITE; NICKEL; TITANIUM; TITANIUM NICKELIDE;

EID: 33745209197     PISSN: 00992399     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.joen.2006.01.003     Document Type: Article
Times cited : (26)

References (36)
  • 1
    • 0024052338 scopus 로고
    • An initial investigation of the bending and torsional properties of nitinol root canal files
    • Walia H., Brantley W.A., and Gerstein H. An initial investigation of the bending and torsional properties of nitinol root canal files. J Endod 14 (1988) 346-351
    • (1988) J Endod , vol.14 , pp. 346-351
    • Walia, H.1    Brantley, W.A.2    Gerstein, H.3
  • 3
    • 0031083690 scopus 로고    scopus 로고
    • Properties of endodontic hand instruments used in rotary motion. Part 3. Resistance to bending and fracture
    • Tepel J., Schäfer E., and Hoppe W. Properties of endodontic hand instruments used in rotary motion. Part 3. Resistance to bending and fracture. J Endod 23 (1997) 141-145
    • (1997) J Endod , vol.23 , pp. 141-145
    • Tepel, J.1    Schäfer, E.2    Hoppe, W.3
  • 4
    • 0036835346 scopus 로고    scopus 로고
    • Fatique resistance of engine driven rotary nickel-titanium endodontic instruments
    • Craveiro de Melo M.C., Bahia M.G.A., and Buono V.T.L. Fatique resistance of engine driven rotary nickel-titanium endodontic instruments. J Endod 28 (2002) 765-769
    • (2002) J Endod , vol.28 , pp. 765-769
    • Craveiro de Melo, M.C.1    Bahia, M.G.A.2    Buono, V.T.L.3
  • 5
    • 0032241088 scopus 로고    scopus 로고
    • Effect of sterilization on cyclic fatigue of rotary nickel-titanium endodontic instruments
    • Mize S.B., Clement D.J., Pruett J.P., and Carnes D.L. Effect of sterilization on cyclic fatigue of rotary nickel-titanium endodontic instruments. J Endod 24 (1998) 843-847
    • (1998) J Endod , vol.24 , pp. 843-847
    • Mize, S.B.1    Clement, D.J.2    Pruett, J.P.3    Carnes, D.L.4
  • 6
    • 0034139365 scopus 로고    scopus 로고
    • Torsional properties of stainless-steel and nickel-titanium files after multiple autoclave sterilizations
    • Hilt B.R., Cunningham C.J., Shen C., and Richards N. Torsional properties of stainless-steel and nickel-titanium files after multiple autoclave sterilizations. J Endod 26 (2000) 76-80
    • (2000) J Endod , vol.26 , pp. 76-80
    • Hilt, B.R.1    Cunningham, C.J.2    Shen, C.3    Richards, N.4
  • 7
    • 0031296835 scopus 로고    scopus 로고
    • Effect of heat sterilization on the torsional properties of rotary nickel-titanium endodontic files
    • Silvaggio J., and Hicks M.L. Effect of heat sterilization on the torsional properties of rotary nickel-titanium endodontic files. J Endod 23 (1997) 731-734
    • (1997) J Endod , vol.23 , pp. 731-734
    • Silvaggio, J.1    Hicks, M.L.2
  • 8
    • 0031987219 scopus 로고    scopus 로고
    • The effect of sterilization on bending and torsional properties of K-files manufactured with different metallic alloys
    • Canalda-Sahli C., Brau-Aguade E., and Sentis-Vilalta J. The effect of sterilization on bending and torsional properties of K-files manufactured with different metallic alloys. Int Endod J 31 (1998) 48-52
    • (1998) Int Endod J , vol.31 , pp. 48-52
    • Canalda-Sahli, C.1    Brau-Aguade, E.2    Sentis-Vilalta, J.3
  • 10
    • 0036778212 scopus 로고    scopus 로고
    • Effect of sterilization on the cutting efficiency of PVD-coated nickel-titanium endodontic instruments
    • Schäfer E. Effect of sterilization on the cutting efficiency of PVD-coated nickel-titanium endodontic instruments. Int Endod J 35 (2002) 867-872
    • (2002) Int Endod J , vol.35 , pp. 867-872
    • Schäfer, E.1
  • 11
    • 0034231421 scopus 로고    scopus 로고
    • An overview of nickel-titanium alloys used in dentistry
    • Thompson S.A. An overview of nickel-titanium alloys used in dentistry. Int Endod J 33 (2000) 297-310
    • (2000) Int Endod J , vol.33 , pp. 297-310
    • Thompson, S.A.1
  • 12
    • 0016662355 scopus 로고
    • Potential applications of certain nickel-titanium (nitinol) alloys
    • Civjan S., Huget E.F., and De Simon L.B. Potential applications of certain nickel-titanium (nitinol) alloys. J Dent Res 54 (1975) 89-96
    • (1975) J Dent Res , vol.54 , pp. 89-96
    • Civjan, S.1    Huget, E.F.2    De Simon, L.B.3
  • 13
    • 0017862032 scopus 로고
    • Laboratory and clinical analyses of nitinol wire
    • Andreasen G.F., and Morrow R.E. Laboratory and clinical analyses of nitinol wire. Am J Orthod 73 (1978) 142-151
    • (1978) Am J Orthod , vol.73 , pp. 142-151
    • Andreasen, G.F.1    Morrow, R.E.2
  • 14
    • 0030162366 scopus 로고    scopus 로고
    • Differential scanning calorimetry (DSC) analyses of superelastic and nonsuperelastic nickel-titanium orthodontic wires
    • Bradley T.G., Brantley W.A., and Culbertson B.M. Differential scanning calorimetry (DSC) analyses of superelastic and nonsuperelastic nickel-titanium orthodontic wires. Am J Orthod Dentofacial Orthop 109 (1996) 589-597
    • (1996) Am J Orthod Dentofacial Orthop , vol.109 , pp. 589-597
    • Bradley, T.G.1    Brantley, W.A.2    Culbertson, B.M.3
  • 15
    • 0033024463 scopus 로고    scopus 로고
    • The NiTi superelastic alloy application to the dentistry field
    • Torrisi L. The NiTi superelastic alloy application to the dentistry field. Biomed Mat Engineering 9 (1999) 39-47
    • (1999) Biomed Mat Engineering , vol.9 , pp. 39-47
    • Torrisi, L.1
  • 16
    • 0036674941 scopus 로고    scopus 로고
    • Differential scanning calorimetric studies of nickel-titanium rotary endodontic instruments
    • Brantley W.A., Svec T.A., Iijima M., Powers J.M., and Grentzer T.H. Differential scanning calorimetric studies of nickel-titanium rotary endodontic instruments. J Endod 28 (2002) 567-572
    • (2002) J Endod , vol.28 , pp. 567-572
    • Brantley, W.A.1    Svec, T.A.2    Iijima, M.3    Powers, J.M.4    Grentzer, T.H.5
  • 17
    • 0036835867 scopus 로고    scopus 로고
    • Differential scanning calorimetric studies of nickel-titanium rotary endodontic instruments after simulated clinical use
    • Brantley W.A., Svec T.A., Iijima M., Powers J.M., and Grentzer T.H. Differential scanning calorimetric studies of nickel-titanium rotary endodontic instruments after simulated clinical use. J Endod 28 (2002) 774-778
    • (2002) J Endod , vol.28 , pp. 774-778
    • Brantley, W.A.1    Svec, T.A.2    Iijima, M.3    Powers, J.M.4    Grentzer, T.H.5
  • 18
    • 0036777866 scopus 로고    scopus 로고
    • Fatigue and mechanical properties of nickel-titanium endodontic instruments
    • Kuhn G., and Jordan L. Fatigue and mechanical properties of nickel-titanium endodontic instruments. J Endod 28 (2002) 716-720
    • (2002) J Endod , vol.28 , pp. 716-720
    • Kuhn, G.1    Jordan, L.2
  • 19
    • 0036777233 scopus 로고    scopus 로고
    • Surface analysis of ProFile instruments by scanning electron microscopy and X-ray energy-dispersive spectroscopy. a preliminary study
    • Martins R.C., Bahia M.G.A., and Buono V.T.L. Surface analysis of ProFile instruments by scanning electron microscopy and X-ray energy-dispersive spectroscopy. a preliminary study. Int Endod J 35 (2002) 848-853
    • (2002) Int Endod J , vol.35 , pp. 848-853
    • Martins, R.C.1    Bahia, M.G.A.2    Buono, V.T.L.3
  • 21
    • 0002205854 scopus 로고
    • Ni-Ti based shape memory alloys
    • Duerig T.W., Melton K.N., Stöckel D., and Wayman C.M. (Eds), Butterworth-Heinemann, London, UK
    • Melton K.N. Ni-Ti based shape memory alloys. In: Duerig T.W., Melton K.N., Stöckel D., and Wayman C.M. (Eds). Engineering aspects of shape memory alloys (1990), Butterworth-Heinemann, London, UK 21-35
    • (1990) Engineering aspects of shape memory alloys , pp. 21-35
    • Melton, K.N.1
  • 22
    • 1542465898 scopus 로고    scopus 로고
    • Scanning electron microscope observations of new and used nickel-titanium rotary files
    • Alapati S.B., Brantley W.A., Svec T.A., Powers J.M., and Mitchell J.C. Scanning electron microscope observations of new and used nickel-titanium rotary files. J Endod 29 (2003) 667-669
    • (2003) J Endod , vol.29 , pp. 667-669
    • Alapati, S.B.1    Brantley, W.A.2    Svec, T.A.3    Powers, J.M.4    Mitchell, J.C.5
  • 23
    • 0030138445 scopus 로고    scopus 로고
    • Morphometric video analysis of the engine driven nickel-titanium Lightspeed instrument system
    • Marsicovetere E.S., Clement D.J., and del Rio C.E. Morphometric video analysis of the engine driven nickel-titanium Lightspeed instrument system. J Endod 22 (1996) 231-235
    • (1996) J Endod , vol.22 , pp. 231-235
    • Marsicovetere, E.S.1    Clement, D.J.2    del Rio, C.E.3
  • 24
    • 0033154787 scopus 로고    scopus 로고
    • Wear of nickel-titanium Lightspeed instruments evaluated by scanning electron microscopy
    • Eggert C., Peters O., and Barbakow F. Wear of nickel-titanium Lightspeed instruments evaluated by scanning electron microscopy. J Endod 25 (1999) 494-497
    • (1999) J Endod , vol.25 , pp. 494-497
    • Eggert, C.1    Peters, O.2    Barbakow, F.3
  • 25
    • 0031108327 scopus 로고    scopus 로고
    • Root canal instruments for manual use. a review
    • Schäfer E. Root canal instruments for manual use. a review. Endod Dental Traumatol 13 (1997) 51-64
    • (1997) Endod Dental Traumatol , vol.13 , pp. 51-64
    • Schäfer, E.1
  • 26
    • 12344257590 scopus 로고    scopus 로고
    • SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical use
    • Alapati S.B., Brantley W.A., Svec T.A., Powers J.M., Nusstein J.M., and Daehn G.S. SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical use. J Endod 31 (2005) 40-43
    • (2005) J Endod , vol.31 , pp. 40-43
    • Alapati, S.B.1    Brantley, W.A.2    Svec, T.A.3    Powers, J.M.4    Nusstein, J.M.5    Daehn, G.S.6
  • 27
    • 2442680167 scopus 로고    scopus 로고
    • K3 Endo, ProTaper, and ProFile systems. breakage and distortion in severely curved roots of molars
    • Ankrum M.T., Hartwell G.R., and Truitt J.E. K3 Endo, ProTaper, and ProFile systems. breakage and distortion in severely curved roots of molars. J Endod 30 (2004) 234-237
    • (2004) J Endod , vol.30 , pp. 234-237
    • Ankrum, M.T.1    Hartwell, G.R.2    Truitt, J.E.3
  • 28
    • 3042653630 scopus 로고    scopus 로고
    • In vitro study of the torsional properties of new and used ProFile nickel titanium rotary files
    • Yared G. In vitro study of the torsional properties of new and used ProFile nickel titanium rotary files. J Endod 30 (2004) 410-412
    • (2004) J Endod , vol.30 , pp. 410-412
    • Yared, G.1
  • 29
    • 20444489249 scopus 로고    scopus 로고
    • A comparison of torque required to fracture rotary files with tips bound in simulated curved canal
    • Guilford W.L., Lemons J.E., and Eleazer P.D. A comparison of torque required to fracture rotary files with tips bound in simulated curved canal. J Endod 31 (2005) 468-470
    • (2005) J Endod , vol.31 , pp. 468-470
    • Guilford, W.L.1    Lemons, J.E.2    Eleazer, P.D.3
  • 30
    • 0030253003 scopus 로고    scopus 로고
    • Enhanced surface hardness by boron implantation in Nitinol alloy
    • Lee D.H., Park J.B., Saxena A., and Serene T.P. Enhanced surface hardness by boron implantation in Nitinol alloy. J Endod 22 (1996) 543-546
    • (1996) J Endod , vol.22 , pp. 543-546
    • Lee, D.H.1    Park, J.B.2    Saxena, A.3    Serene, T.P.4
  • 32
    • 0035458398 scopus 로고    scopus 로고
    • Wear of nickel-titanium endodontic instruments evaluated by SEM. effect of ion implantation
    • Rapisarda E., Bonaccorso A., Tripi T.R., Condorelli G.G., and Torrisi L. Wear of nickel-titanium endodontic instruments evaluated by SEM. effect of ion implantation. J Endod 27 (2001) 588-592
    • (2001) J Endod , vol.27 , pp. 588-592
    • Rapisarda, E.1    Bonaccorso, A.2    Tripi, T.R.3    Condorelli, G.G.4    Torrisi, L.5
  • 33
    • 0033990205 scopus 로고    scopus 로고
    • Effects of sterilization processes on NiTi alloy. surface characterization
    • Thierry B., Tabrizian M., Savadogo O., and Yahia L.H. Effects of sterilization processes on NiTi alloy. surface characterization. J Biomed Mat Res 49 (2000) 88-98
    • (2000) J Biomed Mat Res , vol.49 , pp. 88-98
    • Thierry, B.1    Tabrizian, M.2    Savadogo, O.3    Yahia, L.H.4
  • 34
    • 0034666762 scopus 로고    scopus 로고
    • Effects of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy
    • Thierry B., Tabrizian M., Trepanier C., Savadogo O., and Yahia L.H. Effects of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy. J Biomed Mat Res 51 (2000) 685-693
    • (2000) J Biomed Mat Res , vol.51 , pp. 685-693
    • Thierry, B.1    Tabrizian, M.2    Trepanier, C.3    Savadogo, O.4    Yahia, L.H.5
  • 35
    • 0001884238 scopus 로고
    • Ti-Ni shape memory alloys
    • Boyer R., Welsch G., and Collings E.W. (Eds), ASM International, Materials Park, OH
    • Duerig T.W., and Pelton A.R. Ti-Ni shape memory alloys. In: Boyer R., Welsch G., and Collings E.W. (Eds). Materials properties handbook. titanium alloys (1994), ASM International, Materials Park, OH 1035-1048
    • (1994) Materials properties handbook. titanium alloys , pp. 1035-1048
    • Duerig, T.W.1    Pelton, A.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.