메뉴 건너뛰기




Volumn 82, Issue 1, 2006, Pages 62-67

Superior Mesenteric Artery Blood Flow Modifications During Off-Pump Coronary Surgery

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; BLOOD FLOWMETRY; BLOOD VESSEL SHUNT; CLINICAL ARTICLE; CORONARY ARTERY SURGERY; CORONARY HEMODYNAMICS; CORRELATION ANALYSIS; DOPPLER ECHOGRAPHY; FEMALE; HEART MUSCLE REVASCULARIZATION; HEART OUTPUT; HEART PERFUSION; HUMAN; MALE; MESENTERY BLOOD FLOW; OFF PUMP CORONARY SURGERY; PRIORITY JOURNAL; PROSPECTIVE STUDY; SUPERIOR MESENTERIC ARTERY; SURGICAL TECHNIQUE; TRANSESOPHAGEAL ECHOCARDIOGRAPHY;

EID: 33745188882     PISSN: 00034975     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.athoracsur.2006.02.012     Document Type: Article
Times cited : (26)

References (26)
  • 1
    • 0026758828 scopus 로고
    • Acute mesenteric ischemia after cardiopulmonary bypass
    • Allen K.B., Salam A.A., and Lumsden A.B. Acute mesenteric ischemia after cardiopulmonary bypass. J Vasc Surg 16 (1992) 391-396
    • (1992) J Vasc Surg , vol.16 , pp. 391-396
    • Allen, K.B.1    Salam, A.A.2    Lumsden, A.B.3
  • 2
    • 0026747809 scopus 로고
    • Effects of temperature and flow rate on regional blood flow and metabolism during cardiopulmonary bypass
    • Lazenby W.D., Ko W., Zelano J.A., et al. Effects of temperature and flow rate on regional blood flow and metabolism during cardiopulmonary bypass. Ann Thorac Surg 53 (1992) 957-964
    • (1992) Ann Thorac Surg , vol.53 , pp. 957-964
    • Lazenby, W.D.1    Ko, W.2    Zelano, J.A.3
  • 3
    • 0031909152 scopus 로고    scopus 로고
    • Gastric mucosal oxygen delivery decreases during cardiopulmonary bypass despite constant systemic oxygen delivery
    • Sicsic J.C., Duranteau J., Corbineau H., et al. Gastric mucosal oxygen delivery decreases during cardiopulmonary bypass despite constant systemic oxygen delivery. Anesth Analg 86 (1998) 455-460
    • (1998) Anesth Analg , vol.86 , pp. 455-460
    • Sicsic, J.C.1    Duranteau, J.2    Corbineau, H.3
  • 4
    • 12244263447 scopus 로고    scopus 로고
    • Off-pump coronary artery bypass surgery does not reduce gastrointestinal complications
    • GhS
    • Musleh, Patel N.C., Grayson A.D., et al. Off-pump coronary artery bypass surgery does not reduce gastrointestinal complications. GhS. Eur J Cardiothorac Surg 23 (2003) 170-174
    • (2003) Eur J Cardiothorac Surg , vol.23 , pp. 170-174
    • Musleh1    Patel, N.C.2    Grayson, A.D.3
  • 5
    • 0442276620 scopus 로고    scopus 로고
    • Does off-pump CABG reduce gastrointestinal complications?
    • Sanisoglu I., Guden M., Bayramoglu Z., et al. Does off-pump CABG reduce gastrointestinal complications?. Ann Thorac Surg 77 (2004) 619-625
    • (2004) Ann Thorac Surg , vol.77 , pp. 619-625
    • Sanisoglu, I.1    Guden, M.2    Bayramoglu, Z.3
  • 6
    • 0037710314 scopus 로고    scopus 로고
    • A prospective randomized study to evaluate splanchnic hypoxia during beating-heart and conventional coronary revascularization
    • Velissaris Th., Tang A., Murray M., El-Minshawy A., Hett D., and Ohri S. A prospective randomized study to evaluate splanchnic hypoxia during beating-heart and conventional coronary revascularization. Eur J Cardiothorac Surg 23 (2003) 917-924
    • (2003) Eur J Cardiothorac Surg , vol.23 , pp. 917-924
    • Velissaris, Th.1    Tang, A.2    Murray, M.3    El-Minshawy, A.4    Hett, D.5    Ohri, S.6
  • 7
    • 0032776177 scopus 로고    scopus 로고
    • Exposure of circumflex branches in the tilted, beating porcine heart. Echocardiographic evidence of right ventricular deformation and the effect of right or left heart bypass
    • Gruendemann P.F., Borst C., Verlaan C.W.J., Meijburg H., Moues C.M., and Jansen E.W. Exposure of circumflex branches in the tilted, beating porcine heart. Echocardiographic evidence of right ventricular deformation and the effect of right or left heart bypass. J Thorac Cardiovasc Surg 118 (1999) 316-323
    • (1999) J Thorac Cardiovasc Surg , vol.118 , pp. 316-323
    • Gruendemann, P.F.1    Borst, C.2    Verlaan, C.W.J.3    Meijburg, H.4    Moues, C.M.5    Jansen, E.W.6
  • 8
    • 14644417119 scopus 로고    scopus 로고
    • Hemodynamics in off-pump surgery. normal versus compromised preoperative left ventricular function
    • Fiore G., Latrofa M.E., Tunzi P., et al. Hemodynamics in off-pump surgery. normal versus compromised preoperative left ventricular function. Eur J Cardiothorac Surg 27 (2005) 488-493
    • (2005) Eur J Cardiothorac Surg , vol.27 , pp. 488-493
    • Fiore, G.1    Latrofa, M.E.2    Tunzi, P.3
  • 10
    • 0028920647 scopus 로고
    • Decreased splanchnic perfusion measured by duplex ultrasound in humans undergoing small volume hemorrhage
    • Dalton J.M., Gore D.C., Makhoul R.G., Fisher M.R., and DeMaria E.J. Decreased splanchnic perfusion measured by duplex ultrasound in humans undergoing small volume hemorrhage. Crit Care Med 23 (1995) 491-497
    • (1995) Crit Care Med , vol.23 , pp. 491-497
    • Dalton, J.M.1    Gore, D.C.2    Makhoul, R.G.3    Fisher, M.R.4    DeMaria, E.J.5
  • 11
    • 0031957536 scopus 로고    scopus 로고
    • Abdominal aorta and visceral arteries visualized with transesophageal echocardiography during operations on the aorta
    • Orihashi K., Matsuura Y., Sueda T., et al. Abdominal aorta and visceral arteries visualized with transesophageal echocardiography during operations on the aorta. J Thorac Cardiovasc Surg 115 (1998) 945-947
    • (1998) J Thorac Cardiovasc Surg , vol.115 , pp. 945-947
    • Orihashi, K.1    Matsuura, Y.2    Sueda, T.3
  • 12
    • 0033763016 scopus 로고    scopus 로고
    • Exposure and mechanical stabilization in off-pump coronary artery bypass grafting via sternotomy
    • Ricci M., Karamanoukian H.L., D'Ancona G., Bergsland J., and Salerno T.A. Exposure and mechanical stabilization in off-pump coronary artery bypass grafting via sternotomy. Ann Thorac Surg 70 (2000) 1736-1740
    • (2000) Ann Thorac Surg , vol.70 , pp. 1736-1740
    • Ricci, M.1    Karamanoukian, H.L.2    D'Ancona, G.3    Bergsland, J.4    Salerno, T.A.5
  • 13
    • 0031860963 scopus 로고    scopus 로고
    • Within- and between-day variability in transcutaneous Doppler ultrasound measurements of superior mesenteric artery blood flow (SMABF) in the fasted state
    • Stubbs T.A., and Macdonald I.A. Within- and between-day variability in transcutaneous Doppler ultrasound measurements of superior mesenteric artery blood flow (SMABF) in the fasted state. Physiol Meas 19 (1998) 181-187
    • (1998) Physiol Meas , vol.19 , pp. 181-187
    • Stubbs, T.A.1    Macdonald, I.A.2
  • 14
    • 0032433444 scopus 로고    scopus 로고
    • Measurement of superior mesenteric artery flow by means of Doppler ultrasound in early dumping syndrome
    • Vecht J., van Oostayen J.A., Lamers C.B.H.W., and Masclee A.A.M. Measurement of superior mesenteric artery flow by means of Doppler ultrasound in early dumping syndrome. Am J Gastroenterol 93 (1998) 2380-2384
    • (1998) Am J Gastroenterol , vol.93 , pp. 2380-2384
    • Vecht, J.1    van Oostayen, J.A.2    Lamers, C.B.H.W.3    Masclee, A.A.M.4
  • 15
    • 0031551951 scopus 로고    scopus 로고
    • Effect of perturbations and a meal on superior mesenteric artery flow in patients with orthostatic hypotension
    • PhA
    • Fujimura J., Camilleri M., Low, Novak V., Novak P., and Opfer-Gehrking T.L. Effect of perturbations and a meal on superior mesenteric artery flow in patients with orthostatic hypotension. PhA. J Auton Nerv Syst 67 (1997) 15-23
    • (1997) J Auton Nerv Syst , vol.67 , pp. 15-23
    • Fujimura, J.1    Camilleri, M.2    Low3    Novak, V.4    Novak, P.5    Opfer-Gehrking, T.L.6
  • 16
    • 0037379382 scopus 로고    scopus 로고
    • Splanchnic blood flow in low-flow states
    • Jakob S.M. Splanchnic blood flow in low-flow states. Anesth Analg 96 (2003) 1129-1138
    • (2003) Anesth Analg , vol.96 , pp. 1129-1138
    • Jakob, S.M.1
  • 17
    • 0016165742 scopus 로고
    • Effects of hemorrhage on regional blood flow distribution in dogs and primates
    • Vatner S.F. Effects of hemorrhage on regional blood flow distribution in dogs and primates. J Clin Invest 54 (1974) 225-235
    • (1974) J Clin Invest , vol.54 , pp. 225-235
    • Vatner, S.F.1
  • 18
    • 0029948994 scopus 로고    scopus 로고
    • Determinants of splanchnic blood flow
    • Takala J. Determinants of splanchnic blood flow. Br J Anaesth 77 (1996) 50-58
    • (1996) Br J Anaesth , vol.77 , pp. 50-58
    • Takala, J.1
  • 19
    • 1642580679 scopus 로고    scopus 로고
    • Catecholamine-induced changes in the splanchnic circulation affecting systemic hemodynamics
    • Gelman S., and Mushlin. Catecholamine-induced changes in the splanchnic circulation affecting systemic hemodynamics. Anesthesiology 100 (2004) 434-439
    • (2004) Anesthesiology , vol.100 , pp. 434-439
    • Gelman, S.1    Mushlin2
  • 20
    • 0011286967 scopus 로고
    • Relationship of blood flow to pressure in the intestinal vascular bed of the dog
    • Texter E.C., Merrill S., Schwartz M., Van derStappen G., and Haddy F.J. Relationship of blood flow to pressure in the intestinal vascular bed of the dog. Am J Physiol 202 (1962) 253-256
    • (1962) Am J Physiol , vol.202 , pp. 253-256
    • Texter, E.C.1    Merrill, S.2    Schwartz, M.3    Van derStappen, G.4    Haddy, F.J.5
  • 21
    • 0029117428 scopus 로고
    • Dysregulation of the veno-arterial response in the superior mesenteric artery during endotoxic shock
    • Revelly J.P., Ayuse T., Brienza N., and Robotham J.L. Dysregulation of the veno-arterial response in the superior mesenteric artery during endotoxic shock. Crit Care Med 23 (1995) 1519-1527
    • (1995) Crit Care Med , vol.23 , pp. 1519-1527
    • Revelly, J.P.1    Ayuse, T.2    Brienza, N.3    Robotham, J.L.4
  • 22
    • 0034253912 scopus 로고    scopus 로고
    • Ischemic hepatitis. clinical presentation and pathogenesis
    • Seeto R.K., Fenn B., and Rockey D.C. Ischemic hepatitis. clinical presentation and pathogenesis. Am J Med 109 (2000) 109-113
    • (2000) Am J Med , vol.109 , pp. 109-113
    • Seeto, R.K.1    Fenn, B.2    Rockey, D.C.3
  • 24
    • 0030279912 scopus 로고    scopus 로고
    • Endotoxin-induced inhibition of mesenteric vasodilator responses to acetylcholine, bradykinin, and post-occlusion hyperemia in anesthetized rats
    • Fatehi-Hassanabad Z., Parratt J.R., and Furman B.L. Endotoxin-induced inhibition of mesenteric vasodilator responses to acetylcholine, bradykinin, and post-occlusion hyperemia in anesthetized rats. Shock 5 (1996) 371-376
    • (1996) Shock , vol.5 , pp. 371-376
    • Fatehi-Hassanabad, Z.1    Parratt, J.R.2    Furman, B.L.3
  • 26
    • 0028872208 scopus 로고
    • Gastric mucosal pH does not reflect change in splanchnic blood flow after cardiac surgery
    • Uusaro A., Ruokonen E., and Takala J. Gastric mucosal pH does not reflect change in splanchnic blood flow after cardiac surgery. Br J Anaesth 74 (1995) 149-154
    • (1995) Br J Anaesth , vol.74 , pp. 149-154
    • Uusaro, A.1    Ruokonen, E.2    Takala, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.