-
1
-
-
0030982409
-
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
-
Sodickson DK, Manning WJ. 1997. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 38: 591-603.
-
(1997)
Magn Reson Med
, vol.38
, pp. 591-603
-
-
Sodickson, D.K.1
Manning, W.J.2
-
4
-
-
1542341497
-
Real-time large-FOV MRI with a massively parallel 32-channel MRI system and detector array
-
Toronto
-
Hardy CJ, Darrow RD, Saranathan M, Giaquinto RO, Rohling KW, Dumoulin CL, et al. 2003. Real-time large-FOV MRI with a massively parallel 32-channel MRI system and detector array. Proc ISMRM 11th Annual Meeting, Toronto, p 471.
-
(2003)
Proc ISMRM 11th Annual Meeting
, pp. 471
-
-
Hardy, C.J.1
Darrow, R.D.2
Saranathan, M.3
Giaquinto, R.O.4
Rohling, K.W.5
Dumoulin, C.L.6
-
5
-
-
0742334055
-
Highly parallel volumetric imaging with accelerated spatial encoding along two dimensions
-
Zhu Y, Hardy C, Giaquinto R, Rohling K, Dumoulin C, Sodickson D, et al. 2003. Highly parallel volumetric imaging with accelerated spatial encoding along two dimensions. Proc ISMRM 11th Annual Meeting, Toronto, p 22.
-
(2003)
Proc ISMRM 11th Annual Meeting, Toronto
, pp. 22
-
-
Zhu, Y.1
Hardy, C.2
Giaquinto, R.3
Rohling, K.4
Dumoulin, C.5
Sodickson, D.6
-
8
-
-
33646356909
-
A new coil array for SENSE imaging with four or eight receivers
-
Honolulu
-
Spence D, Fujita H. 2002. A new coil array for SENSE imaging with four or eight receivers. Proc ISMRM 10th Annual Meeting, Honolulu, p 263.
-
(2002)
Proc ISMRM 10th Annual Meeting
, pp. 263
-
-
Spence, D.1
Fujita, H.2
-
9
-
-
33646375097
-
A novel 8-channel head coil for 3T horizontal systems
-
Honolulu
-
Brown D. 2002. A novel 8-channel head coil for 3T horizontal systems. Proc ISMRM 10th Annual Meeting, Honolulu, p 274.
-
(2002)
Proc ISMRM 10th Annual Meeting
, pp. 274
-
-
Brown, D.1
-
10
-
-
33646338397
-
Synergy body coil optimal design for SENSE imaging
-
Honolulu
-
Haans PC. 2002. Synergy body coil optimal design for SENSE imaging. Proc ISMRM 10th Annual Meeting, Honolulu, p 276.
-
(2002)
Proc ISMRM 10th Annual Meeting
, pp. 276
-
-
Haans, P.C.1
-
11
-
-
0025226022
-
The NMR phased array
-
Roemer PB, Edelstein WA, Hayes CE, Souza SP, Mueller OM. 1990. The NMR phased array. Magn Reson Med 16:192-225.
-
(1990)
Magn Reson Med
, vol.16
, pp. 192-225
-
-
Roemer, P.B.1
Edelstein, W.A.2
Hayes, C.E.3
Souza, S.P.4
Mueller, O.M.5
-
12
-
-
0035088669
-
Planar strip array (PSA) for MRI
-
Lee RF, Charles RW, Robert GW, David CN, Paul AB. 2001. Planar strip array (PSA) for MRI. Magn Reson Med 45:673-683.
-
(2001)
Magn Reson Med
, vol.45
, pp. 673-683
-
-
Lee, R.F.1
Charles, R.W.2
Robert, G.W.3
David, C.N.4
Paul, A.B.5
-
13
-
-
0036260602
-
Design of a SENSE-optimized high-sensitivity MRI receive coil for brain imaging
-
Zwart JA, Ledden PJ, Kellman P, Gelderen P, Duyn JH. 2002. Design of a SENSE-optimized high-sensitivity MRI receive coil for brain imaging. Magn Reson Med 47:1218-1227.
-
(2002)
Magn Reson Med
, vol.47
, pp. 1218-1227
-
-
Zwart, J.A.1
Ledden, P.J.2
Kellman, P.3
Gelderen, P.4
Duyn, J.H.5
-
14
-
-
0035107966
-
Specific coil design for SENSE: A six-element cardiac array
-
Weiger M, Pruessmann KP, Leussler C, Röschmann P, Boesiger P. 2001. Specific coil design for SENSE: a six-element cardiac array. Magn Reson Med 45:495-504.
-
(2001)
Magn Reson Med
, vol.45
, pp. 495-504
-
-
Weiger, M.1
Pruessmann, K.P.2
Leussler, C.3
Röschmann, P.4
Boesiger, P.5
-
17
-
-
0034405181
-
The principle of reciprocity in signal strength calculations-a mathematical guide
-
Hoult DI. 2000. The principle of reciprocity in signal strength calculations-a mathematical guide. Concepts Magn Reson 12(4):173-187.
-
(2000)
Concepts Magn Reson
, vol.12
, Issue.4
, pp. 173-187
-
-
Hoult, D.I.1
-
18
-
-
0035088714
-
Calculations of B, distribution, SNR, and SAR for a surface coil adjacent to an anatomically accurate human body model
-
Collins CM, Smith MB. 2001. Calculations of B, distribution, SNR, and SAR for a surface coil adjacent to an anatomically accurate human body model. Magn Reson Med 45:692-699.
-
(2001)
Magn Reson Med
, vol.45
, pp. 692-699
-
-
Collins, C.M.1
Smith, M.B.2
-
19
-
-
0036324249
-
Polarization of the RF field in a human head at high field: A study with a quadrature surface coil at 7.0T
-
Wang J, Yang Q, Zhang X, Collins CM, Smith MB, Zhu XH, et al. 2002. Polarization of the RF field in a human head at high field: a study with a quadrature surface coil at 7.0T. Magn Reson Med 48:362-369.
-
(2002)
Magn Reson Med
, vol.48
, pp. 362-369
-
-
Wang, J.1
Yang, Q.2
Zhang, X.3
Collins, C.M.4
Smith, M.B.5
Zhu, X.H.6
-
20
-
-
0036238849
-
Different excitation and reception distributions with a single-loop transmit-receive surface coil near a head-sized spherical phantom at 300 MHz
-
Collins CM, Yang QX, Wang JH, Zhang X, Liu H, Michaeli S, et al. 2002. Different excitation and reception distributions with a single-loop transmit-receive surface coil near a head-sized spherical phantom at 300 MHz. Magn Reson Med 47:1026-1028.
-
(2002)
Magn Reson Med
, vol.47
, pp. 1026-1028
-
-
Collins, C.M.1
Yang, Q.X.2
Wang, J.H.3
Zhang, X.4
Liu, H.5
Michaeli, S.6
|