메뉴 건너뛰기




Volumn 43, Issue 5, 2000, Pages 716-725

An analytical SMASH procedure (ASP) for sensitivity-encoded MRI

Author keywords

ASP; Harmonics; Image reconstruction; Phase correction; Phase encoding; Phased arrays MRI; SMASH

Indexed keywords

ENCODING (SYMBOLS); GRADIENT METHODS; HARMONIC ANALYSIS; IMAGE RECONSTRUCTION; INVERSE PROBLEMS; MATHEMATICAL TRANSFORMATIONS; NUMERICAL METHODS; SIGNAL ENCODING;

EID: 0034055389     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2594(200005)43:5<716::AID-MRM14>3.0.CO;2-K     Document Type: Article
Times cited : (19)

References (16)
  • 2
    • 0025977683 scopus 로고
    • Arrays of mutually coupled receiver coils: Theory and application
    • Wright SM, Magin RI, Kelton JR. Arrays of mutually coupled receiver coils: theory and application. Magn Reson Med 1991;17:252-268.
    • (1991) Magn Reson Med , vol.17 , pp. 252-268
    • Wright, S.M.1    Magin, R.I.2    Kelton, J.R.3
  • 3
    • 8244264760 scopus 로고    scopus 로고
    • What is the optimum phased array coil design for cardiac and torso magnetic resonance?
    • Bottomley PA, Olivieri CHL, Giaquinto R. What is the optimum phased array coil design for cardiac and torso magnetic resonance? Magn Reson Med 1997;37:591-599.
    • (1997) Magn Reson Med , vol.37 , pp. 591-599
    • Bottomley, P.A.1    Olivieri, C.H.L.2    Giaquinto, R.3
  • 4
    • 0023870882 scopus 로고
    • Fast MRI data acquisition using multiple detectors
    • Hutchinson M, Raff U. Fast MRI data acquisition using multiple detectors. Magn Reson Med 1988;6:87-91.
    • (1988) Magn Reson Med , vol.6 , pp. 87-91
    • Hutchinson, M.1    Raff, U.2
  • 5
    • 0025777470 scopus 로고
    • A decoupled coil detector array for fast image acquisition in magnetic resonance imaging
    • Kwiat D, Einav S, Navon F. A decoupled coil detector array for fast image acquisition in magnetic resonance imaging. Med Phys 1991;18: 251-265.
    • (1991) Med Phys , vol.18 , pp. 251-265
    • Kwiat, D.1    Einav, S.2    Navon, F.3
  • 6
    • 0027173207 scopus 로고
    • Imaging time reduction through multiple receiver coil data acquisition and image reconstruction
    • Carlson JW, Minemura T. Imaging time reduction through multiple receiver coil data acquisition and image reconstruction. Magn Reson Med 1993;29:681-688.
    • (1993) Magn Reson Med , vol.29 , pp. 681-688
    • Carlson, J.W.1    Minemura, T.2
  • 7
    • 0027319233 scopus 로고
    • Fast imaging using subencoding data sets from multiple detectors
    • Ra JB, Rim CY. Fast imaging using subencoding data sets from multiple detectors. Magn Reson Med 1993;30:142-145.
    • (1993) Magn Reson Med , vol.30 , pp. 142-145
    • Ra, J.B.1    Rim, C.Y.2
  • 8
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997;38:591-603.
    • (1997) Magn Reson Med , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 11
    • 0029142688 scopus 로고
    • Calculation of the signal-to-noise ratio for simple surface coils and arrays of coils
    • Wang J, Reykowski A, Dickas J. Calculation of the signal-to-noise ratio for simple surface coils and arrays of coils. IEEE Trans Biomed Eng 1995;42:908-917.
    • (1995) IEEE Trans Biomed Eng , vol.42 , pp. 908-917
    • Wang, J.1    Reykowski, A.2    Dickas, J.3
  • 12
    • 0029294178 scopus 로고
    • The signal-to-noise ratio of nuclear magnetic resonance surface coils and application to a lossy dielectric cylinder model
    • Vesselle H, Collin E. The signal-to-noise ratio of nuclear magnetic resonance surface coils and application to a lossy dielectric cylinder model. IEEE Trans Biomed Eng 1995;42:497-520.
    • (1995) IEEE Trans Biomed Eng , vol.42 , pp. 497-520
    • Vesselle, H.1    Collin, E.2
  • 13
    • 0031884051 scopus 로고    scopus 로고
    • Ultimate intrinsic signal-to-noise ratio in MRI
    • Ocali O, Atalar E. Ultimate intrinsic signal-to-noise ratio in MRI. Magn Reson Med 1998;39:462-473.
    • (1998) Magn Reson Med , vol.39 , pp. 462-473
    • Ocali, O.1    Atalar, E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.