메뉴 건너뛰기




Volumn 13, Issue 2-3, 2006, Pages 724-747

Supervisory fuzzy control of a base-isolated benchmark building utilizing a neuro-fuzzy model of controllable fluid viscous dampers

Author keywords

Base isolation; Benchmark; Controllable viscous damper; Structural control; Supervisory fuzzy logic

Indexed keywords

BENCHMARKING; DAMPING; INTELLIGENT BUILDINGS; MATHEMATICAL MODELS; VISCOSITY;

EID: 33646345830     PISSN: 15452255     EISSN: 15452263     Source Type: Journal    
DOI: 10.1002/stc.108     Document Type: Article
Times cited : (58)

References (35)
  • 2
    • 0346950269 scopus 로고    scopus 로고
    • Nagarajaiah S. State of the art of structural control
    • Spencer BF, Nagarajaiah S. State of the art of structural control. Journal of Structural Engineering (ASCE) 2003; 129(7):845-856.
    • (2003) Journal of Structural Engineering (ASCE) , vol.129 , Issue.7 , pp. 845-856
    • Spencer, B.F.1
  • 6
    • 0006556575 scopus 로고
    • Development and experimental study of semi-active fluid damping devices for seismic protection of structures
    • National Center for Earthquake Engineering Research, State University of New York, Buffalo
    • Symans MD, Constantinou MC. Development and experimental study of semi-active fluid damping devices for seismic protection of structures. Report NCEER 95-0011, National Center for Earthquake Engineering Research, State University of New York, Buffalo, 1995.
    • (1995) Report NCEER , vol.95 , Issue.11
    • Symans, M.D.1    Constantinou, M.C.2
  • 8
    • 0000720266 scopus 로고    scopus 로고
    • Passive fluid viscous damping systems for seismic energy dissipation
    • Symans MD, Constantinou MC. Passive fluid viscous damping systems for seismic energy dissipation. Journal of Earthquake Technology 1998; 35(4): 185-206.
    • (1998) Journal of Earthquake Technology , vol.35 , Issue.4 , pp. 185-206
    • Symans, M.D.1    Constantinou, M.C.2
  • 10
    • 0031195098 scopus 로고    scopus 로고
    • Seismic testing of a building structure with a semi-active fluid damper control system
    • Symans MD, Constantinou MC. Seismic testing of a building structure with a semi-active fluid damper control system. Earthquake Engineering and Structural Dynamics 1997; 26(7):759-777.
    • (1997) Earthquake Engineering and Structural Dynamics , vol.26 , Issue.7 , pp. 759-777
    • Symans, M.D.1    Constantinou, M.C.2
  • 11
    • 0033063152 scopus 로고    scopus 로고
    • Fuzzy logic control of bridge structures using intelligent semiactive seismic isolation systems
    • Symans MD, Kelly SW. Fuzzy logic control of bridge structures using intelligent semiactive seismic isolation systems. Earthquake Engineering and Structural Dynamics 1999; 28(1):37-60.
    • (1999) Earthquake Engineering and Structural Dynamics , vol.28 , Issue.1 , pp. 37-60
    • Symans, M.D.1    Kelly, S.W.2
  • 13
    • 33646363437 scopus 로고    scopus 로고
    • Application of supervisory fuzzy logic controller to the base-isolated bench-mark structure
    • ASCE, Newark, DE, June, CDROM
    • Reigles DG, Symans MD. Application of supervisory fuzzy logic controller to the base-isolated bench-mark structure. Proceedings of the 17th Engineering Mechanics Conference, ASCE, Newark, DE, June 2004, CDROM.
    • (2004) Proceedings of the 17th Engineering Mechanics Conference
    • Reigles, D.G.1    Symans, M.D.2
  • 22
    • 33646358823 scopus 로고    scopus 로고
    • The MathWorks, Inc., Natick, MA
    • SIMULINK Using Simulink. The MathWorks, Inc., Natick, MA, 2004.
    • (2004) SIMULINK Using Simulink
  • 24
    • 0002164360 scopus 로고
    • Fuzzy controller for structures with hybrid isolation systems
    • Los Angeles, CA
    • Nagarajaiah S. Fuzzy controller for structures with hybrid isolation systems. Proceedings of 1st World Conference on Structural Control, Los Angeles, CA, vol. TA2, 1994; 67-76.
    • (1994) Proceedings of 1st World Conference on Structural Control , vol.TA2 , pp. 67-76
    • Nagarajaiah, S.1
  • 29
    • 18844437312 scopus 로고    scopus 로고
    • Fuzzy supervisory control of earthquake-excited cable-stayed bridges
    • Park K-S, Koh H-M, Ok S-Y, Seo C-W. Fuzzy supervisory control of earthquake-excited cable-stayed bridges. Engineering Structures 2005; 27(7): 1086-1100.
    • (2005) Engineering Structures , vol.27 , Issue.7 , pp. 1086-1100
    • Park, K.-S.1    Koh, H.-M.2    Ok, S.-Y.3    Seo, C.-W.4
  • 34
    • 13844262588 scopus 로고    scopus 로고
    • Application of a genetic algorithm for optimal damper distribution within the nonlinear seismic benchmark building
    • Wongprasert N, Symans MD. Application of a genetic algorithm for optimal damper distribution within the nonlinear seismic benchmark building. Journal of Engineering Mechanics (ASCE) 2004; 130(4):401-406.
    • (2004) Journal of Engineering Mechanics (ASCE) , vol.130 , Issue.4 , pp. 401-406
    • Wongprasert, N.1    Symans, M.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.