메뉴 건너뛰기




Volumn 103, Issue 4, 2006, Pages 317-320

Goldmann applanation tonometry and dynamic contour tonometry. Comparison of intraocular pressure measurements in the course of product certification according to EN ISO 8612:2001;Goldmann-applanationstonometrie und dynamische konturtonometrie. Vergleich der intraokularen druckmessung im rahmen einer typprüfung nach EN ISO 8612:2001

Author keywords

Dynamic contour tonometry; Glaucoma; Goldmann applanation tonometry; Tonometry

Indexed keywords

ARTICLE; CERTIFICATION; CLINICAL TRIAL; CORNEA THICKNESS; DYNAMIC CONTOUR TONOMETRY; GOLDMANN APPLANATION TONOMETRY; HUMAN; INTERMETHOD COMPARISON; INTRAOCULAR PRESSURE; OCULOPLETHYSMOGRAPHY; PRESSURE MEASUREMENT; STANDARD; TONOMETRY;

EID: 33645817489     PISSN: 0941293X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00347-006-1318-7     Document Type: Article
Times cited : (11)

References (11)
  • 1
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1: 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 2
    • 11344262810 scopus 로고    scopus 로고
    • Comparison of the Tono-Pen and Goldmann tonometer for measuring intraocular pressure in patients with glaucoma
    • Horowitz GS, Byles J, Lee J, D'Este C (2004) Comparison of the Tono-Pen and Goldmann tonometer for measuring intraocular pressure in patients with glaucoma. Clin Experiment Ophthalmol 32: 584-589
    • (2004) Clin Experiment Ophthalmol , vol.32 , pp. 584-589
    • Horowitz, G.S.1    Byles, J.2    Lee, J.3    D'Este, C.4
  • 3
    • 14744269161 scopus 로고    scopus 로고
    • Intraocular pressure and systemic blood pressure: Longitudinal perspective: The Beaver Dam Eye Study
    • Klein BE, Klein R, Knudtson MD (2005) Intraocular pressure and systemic blood pressure: longitudinal perspective: the Beaver Dam Eye Study. Br J Ophthalmol 89: 284-287
    • (2005) Br J Ophthalmol , vol.89 , pp. 284-287
    • Klein, B.E.1    Klein, R.2    Knudtson, M.D.3
  • 4
    • 33645823534 scopus 로고    scopus 로고
    • Comparison of intraocular pressure measured by Pascal dynamic contour tonometry and Goldmann applanation tonometry
    • Ku JY, Danesh-Meyer HV, Craig JP, Gamble GD, McGhee CN (2005) Comparison of intraocular pressure measured by Pascal dynamic contour tonometry and Goldmann applanation tonometry. Eye 20: 191-198
    • (2005) Eye , vol.20 , pp. 191-198
    • Ku, J.Y.1    Danesh-Meyer, H.V.2    Craig, J.P.3    Gamble, G.D.4    McGhee, C.N.5
  • 5
    • 0036016618 scopus 로고    scopus 로고
    • Statistical techniques for comparing measurers and methods of measurement: A critical review
    • Ludbrook J (2002) Statistical techniques for comparing measurers and methods of measurement: a critical review. Clin Exp Pharmacol Physiol 29: 527-536
    • (2002) Clin Exp Pharmacol Physiol , vol.29 , pp. 527-536
    • Ludbrook, J.1
  • 6
    • 17644364035 scopus 로고    scopus 로고
    • Clinical evaluation of the pressure phosphene tonometer in patients with glaucoma
    • Rietveld E, van den Bremer DA, Volker-Dieben HJ (2005) Clinical evaluation of the pressure phosphene tonometer in patients with glaucoma. Br J Ophthalmol 89: 537-539
    • (2005) Br J Ophthalmol , vol.89 , pp. 537-539
    • Rietveld, E.1    Van Den Bremer, D.A.2    Volker-Dieben, H.J.3
  • 7
    • 30344442785 scopus 로고    scopus 로고
    • Changes in corneal thickness and curvature after different excimer laser photorefractive procedures and their impact on intraocular pressure measurements
    • Svedberg H, Chen E, Hamberg-Nystrom H (2005) Changes in corneal thickness and curvature after different excimer laser photorefractive procedures and their impact on intraocular pressure measurements. Graefes Arch Clin Exp Ophthalmol 243: 1218-1220
    • (2005) Graefes Arch Clin Exp Ophthalmol , vol.243 , pp. 1218-1220
    • Svedberg, H.1    Chen, E.2    Hamberg-Nystrom, H.3
  • 8
    • 21344460937 scopus 로고    scopus 로고
    • The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry
    • Tonnu PA, Ho T, Newson T et al. (2005) The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry. Br J Ophthalmol 89: 851-854
    • (2005) Br J Ophthalmol , vol.89 , pp. 851-854
    • Tonnu, P.A.1    Ho, T.2    Newson, T.3
  • 9
    • 25844453882 scopus 로고    scopus 로고
    • Deviations between transpalpebral tonometry using TGDc-01 and Goldmann applanation tonometry depending on the IOP level
    • Troost A, Specht K, Krummenauer F, Yun SH, Schwenn O (2005) Deviations between transpalpebral tonometry using TGDc-01 and Goldmann applanation tonometry depending on the IOP level. Graefes Arch Clin Exp Ophthalmol 243: 853-858
    • (2005) Graefes Arch Clin Exp Ophthalmol , vol.243 , pp. 853-858
    • Troost, A.1    Specht, K.2    Krummenauer, F.3    Yun, S.H.4    Schwenn, O.5
  • 10
    • 14744271937 scopus 로고    scopus 로고
    • Transpalpebral tonometry: Reliability and comparison with Goldmann applanation tonometry and palpation in healthy volunteers
    • Troost A, Yun SH, Specht K, Krummenauer F, Schwenn O (2005) Transpalpebral tonometry: reliability and comparison with Goldmann applanation tonometry and palpation in healthy volunteers. Br J Ophthalmol 89: 280-283
    • (2005) Br J Ophthalmol , vol.89 , pp. 280-283
    • Troost, A.1    Yun, S.H.2    Specht, K.3    Krummenauer, F.4    Schwenn, O.5
  • 11
    • 18744368475 scopus 로고    scopus 로고
    • Measurement of intraocular pressure using the NT-4000: A new non-contact tonometer equipped with pulse synchronous measurement function
    • Yaoeda K, Shirakashi M, Fukushima A et al. (2005) Measurement of intraocular pressure using the NT-4000: a new non-contact tonometer equipped with pulse synchronous measurement function. J Glaucoma 14: 201-205
    • (2005) J Glaucoma , vol.14 , pp. 201-205
    • Yaoeda, K.1    Shirakashi, M.2    Fukushima, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.