메뉴 건너뛰기




Volumn 243, Issue 12, 2005, Pages 1218-1220

Changes in corneal thickness and curvature after different excimer laser photorefractive procedures and their impact on intraocular pressure measurements

Author keywords

Corneal curvature; Corneal thickness; Excimer laser refractive procedures; Goldmann tonometry; Intraocular pressure

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; CORNEA CURVATURE; CORNEA THICKNESS; FEMALE; HUMAN; INTRAOCULAR PRESSURE; LASER EPITHELIAL KERATOMILEUSIS; MALE; PHOTOREFRACTIVE KERATECTOMY; POSTOPERATIVE PERIOD; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; RETROSPECTIVE STUDY; SURGICAL TECHNIQUE; TONOMETRY;

EID: 30344442785     PISSN: 0721832X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00417-005-0072-x     Document Type: Article
Times cited : (33)

References (16)
  • 1
    • 0030897864 scopus 로고    scopus 로고
    • Reduction in intraocular pressure after excimer laser photorefractive keratectomy
    • Chatterjee A, Shah S, Bessant D et al (1997) Reduction in intraocular pressure after excimer laser photorefractive keratectomy. Ophthalmology 104:335-359
    • (1997) Ophthalmology , vol.104 , pp. 335-359
    • Chatterjee, A.1    Shah, S.2    Bessant, D.3
  • 2
    • 0016663381 scopus 로고
    • Applanation tonometry and central corneal thickness
    • Ehlers N, Bramsen T, Sperlong S (1975) Applanation tonometry and central corneal thickness. Acta Ophthalmol 53:34-43
    • (1975) Acta Ophthalmol , vol.53 , pp. 34-43
    • Ehlers, N.1    Bramsen, T.2    Sperlong, S.3
  • 3
    • 0035163029 scopus 로고    scopus 로고
    • Correlation between central corneal thickness, applanation tonometry, and direct intracameral readings
    • 10.1136/bjo.85.1.85
    • Feltgen N, Leifert D, Funk J (2001) Correlation between central corneal thickness, applanation tonometry, and direct intracameral readings. Br J Ophthalmol 85:85-87 10.1136/bjo.85.1.85
    • (2001) Br J Ophthalmol , vol.85 , pp. 85-87
    • Feltgen, N.1    Leifert, D.2    Funk, J.3
  • 4
    • 70449195078 scopus 로고
    • Über Applanationstonometrie
    • 13484216
    • Goldmann H, Schmidt T (1957) Über Applanationstonometrie. Ophthalmologica 134:221-242 13484216
    • (1957) Ophthalmologica , vol.134 , pp. 221-242
    • Goldmann, H.1    Schmidt, T.2
  • 5
    • 3242811374 scopus 로고    scopus 로고
    • Accuracy and precision of EyeSys and Orbscan systems on calibrated spherical test surfaces
    • 15260351
    • Gonzalez Perez J, Cervino A, Giraldez MJ et al (2004) Accuracy and precision of EyeSys and Orbscan systems on calibrated spherical test surfaces. Eye Contact Lens 30(2):74-78 15260351
    • (2004) Eye Contact Lens , vol.30 , Issue.2 , pp. 74-78
    • Gonzalez Perez, J.1    Cervino, A.2    Giraldez, M.J.3
  • 6
    • 0030972723 scopus 로고    scopus 로고
    • The effective of excimer laser photorefractive keratectomy on intraocular pressure measurements using the Goldmann applanation tonomter
    • 9186434
    • Mardelli P, Piebenga L, Witacre M et al (1997) The effective of excimer laser photorefractive keratectomy on intraocular pressure measurements using the Goldmann applanation tonomter. Ophthalmology 104:945-949 9186434
    • (1997) Ophthalmology , vol.104 , pp. 945-949
    • Mardelli, P.1    Piebenga, L.2    Witacre, M.3
  • 7
    • 0037316314 scopus 로고    scopus 로고
    • Corneal thickness and intraocular pressure in the Barbados eye studies
    • 10.1001/archopht.121.6.856
    • Nemesure B, Wu SY, Hennis A et al (2003) Corneal thickness and intraocular pressure in the Barbados eye studies. Arch Ophthalmol 121(2):240-244 10.1001/archopht.121.6.856
    • (2003) Arch Ophthalmol , vol.121 , Issue.2 , pp. 240-244
    • Nemesure, B.1    Wu, S.Y.2    Hennis, A.3
  • 8
    • 0038072968 scopus 로고    scopus 로고
    • Central corneal thickness and measured IOP: A clinical study
    • 12703686
    • Philips LJ, Cackanac CJ, Eger MW et al (2003) Central corneal thickness and measured IOP: A clinical study. Optometry 74(4):218-225 12703686
    • (2003) Optometry , vol.74 , Issue.4 , pp. 218-225
    • Philips, L.J.1    Cackanac, C.J.2    Eger, M.W.3
  • 9
    • 0028864226 scopus 로고
    • Intraocular pressure after excimer laser photorefractive keratectomy for myopia
    • 8528915
    • Schipper I, Senn P, Thomann U et al (1995) Intraocular pressure after excimer laser photorefractive keratectomy for myopia. J Refract Surg 11:366-370 8528915
    • (1995) J Refract Surg , vol.11 , pp. 366-370
    • Schipper, I.1    Senn, P.2    Thomann, U.3
  • 10
    • 0033498048 scopus 로고    scopus 로고
    • Relationship between corneal thickness and measured intraocular pressure in a general ophthalmology clinic
    • 10.1016/S0161-6420(99)90498-0
    • Shah S, Chatterjee A, Mathai M et al (1999) Relationship between corneal thickness and measured intraocular pressure in a general ophthalmology clinic. Ophthalmology 106(11):2154-2160 10.1016/S0161-6420(99)90498-0
    • (1999) Ophthalmology , vol.106 , Issue.11 , pp. 2154-2160
    • Shah, S.1    Chatterjee, A.2    Mathai, M.3
  • 11
    • 0141682012 scopus 로고    scopus 로고
    • Intraocular pressure, Goldmann applanation tension, corneal thickness, and corneal curvature in Caucasians, Asians, Hispanics, and African Americans
    • 10.1016/S0002-9394(03)00424-0
    • Shimmyo M, Ross AJ, Moy A et al (2003) Intraocular pressure, Goldmann applanation tension, corneal thickness, and corneal curvature in Caucasians, Asians, Hispanics, and African Americans. Am J Ophthalmol 136(4):603-613 10.1016/S0002-9394(03)00424-0
    • (2003) Am J Ophthalmol , vol.136 , Issue.4 , pp. 603-613
    • Shimmyo, M.1    Ross, A.J.2    Moy, A.3
  • 12
    • 0031848594 scopus 로고    scopus 로고
    • Applanation tonometry and correction according to corneal thickness
    • 10.1034/j.1600-0420.1998.760313.x
    • Stodtmeister R (1998) Applanation tonometry and correction according to corneal thickness. Acta Ophthalmol Scand 76(3):319-324 10.1034/ j.1600-0420.1998.760313.x
    • (1998) Acta Ophthalmol Scand , vol.76 , Issue.3 , pp. 319-324
    • Stodtmeister, R.1
  • 13
    • 30344487495 scopus 로고    scopus 로고
    • European Glaucoma Society
    • Terminology and guidelines for glaucoma
    • Terminology and guidelines for glaucoma (2002) European Glaucoma Society
    • (2002)
  • 14
    • 0027269723 scopus 로고
    • The effect of central corneal thickness on applanation tonometry
    • 8488910
    • Whitacre M, Stein R, Hassanein K (1993) The effect of central corneal thickness on applanation tonometry. Am J Ophthalmol 115:592-596 8488910
    • (1993) Am J Ophthalmol , vol.115 , pp. 592-596
    • Whitacre, M.1    Stein, R.2    Hassanein, K.3
  • 15
    • 0030963090 scopus 로고    scopus 로고
    • Distribution of central corneal thickness and its association with intraocular pressure: The Rotterdam Study
    • 9535620
    • Wolfs RC, Klaver CC, Vingerling JR et al (1997) Distribution of central corneal thickness and its association with intraocular pressure: The Rotterdam Study. Am J Ophthalmol 123(6):767-772 9535620
    • (1997) Am J Ophthalmol , vol.123 , Issue.6 , pp. 767-772
    • Wolfs, R.C.1    Klaver, C.C.2    Vingerling, J.R.3
  • 16
    • 0037226572 scopus 로고    scopus 로고
    • Refractive errors, intraocular pressure, and glaucoma in a white population
    • 10.1016/S0161-6420(02)01260-5
    • Wong T, Klein B, Klein R et al (2003) Refractive errors, intraocular pressure, and glaucoma in a white population. Ophthalmology 110:211-217 10.1016/S0161-6420(02)01260-5
    • (2003) Ophthalmology , vol.110 , pp. 211-217
    • Wong, T.1    Klein, B.2    Klein, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.