메뉴 건너뛰기




Volumn 4, Issue 3, 2006, Pages 213-218

A biomechanical comparison of three anterior thoracolumbar implants after corpectomy: Are two screws better than one?

Author keywords

Anterior fixation; Biomechanics; Corpectomy; Thoracic spine

Indexed keywords

ARTICLE; BONE BOWING; BONE PLATE; BONE SCREW; HUMAN; IMPLANT; INTERMETHOD COMPARISON; RANGE OF MOTION; THORACIC SPINE; THORACOLUMBAR SPINE; ADULT; AGED; BIOMECHANICS; CADAVER; FEMALE; INSTRUMENTATION; JOINT CHARACTERISTICS AND FUNCTIONS; LUMBAR VERTEBRA; MALE; MIDDLE AGED; PATHOLOGY; PROSTHESIS; SPINE FUSION; VERTEBRA;

EID: 33645747177     PISSN: 15475654     EISSN: None     Source Type: Journal    
DOI: 10.3171/spi.2006.4.3.213     Document Type: Article
Times cited : (16)

References (12)
  • 1
    • 0029096617 scopus 로고
    • An apparatus for applying pure nonconstraining moments to spine segments in vitro
    • Crawford NR, Brantley AG, Dickman CA, Koeneman EJ: An apparatus for applying pure nonconstraining moments to spine segments in vitro. Spine 20:2097-2100, 1995
    • (1995) Spine , vol.20 , pp. 2097-2100
    • Crawford, N.R.1    Brantley, A.G.2    Dickman, C.A.3    Koeneman, E.J.4
  • 2
    • 0030996697 scopus 로고    scopus 로고
    • Construction of local vertebral coordinate systems using a digitizing probe. Technical note
    • Crawford NR, Dickman CA: Construction of local vertebral coordinate systems using a digitizing probe. Technical note. Spine 22:559-563, 1997
    • (1997) Spine , vol.22 , pp. 559-563
    • Crawford, N.R.1    Dickman, C.A.2
  • 3
    • 0031726313 scopus 로고    scopus 로고
    • The spinal lax zone and neutral zone: Measurement techniques and parameter comparisons
    • Crawford NR, Peles JD, Dickman CA: The spinal lax zone and neutral zone: measurement techniques and parameter comparisons. J Spinal Disord 11:416-429, 1998
    • (1998) J Spinal Disord , vol.11 , pp. 416-429
    • Crawford, N.R.1    Peles, J.D.2    Dickman, C.A.3
  • 5
  • 6
    • 0038386765 scopus 로고    scopus 로고
    • A biomechanical analysis of triangulation of anterior vertebral double-screw fixation
    • Huang TJ, Hsu RW, Tai CL, Chen WP: A biomechanical analysis of triangulation of anterior vertebral double-screw fixation. Clin Biomech (Bristol, Avon) 18:S40-S45, 2003
    • (2003) Clin Biomech (Bristol, Avon) , vol.18
    • Huang, T.J.1    Hsu, R.W.2    Tai, C.L.3    Chen, W.P.4
  • 7
    • 0033105547 scopus 로고    scopus 로고
    • Biomechanical analysis of anterior versus circumferential spinal reconstruction for various anatomic stages of tumor lesions
    • Kanayama M, Ng JT, Cunningham BW, Abumi K, Kaneda K, McAfee PC: Biomechanical analysis of anterior versus circumferential spinal reconstruction for various anatomic stages of tumor lesions. Spine 24:445-450, 1999
    • (1999) Spine , vol.24 , pp. 445-450
    • Kanayama, M.1    Ng, J.T.2    Cunningham, B.W.3    Abumi, K.4    Kaneda, K.5    McAfee, P.C.6
  • 8
    • 0029977364 scopus 로고    scopus 로고
    • New anterior instrumentation for the management of thoracolumbar and lumbar scoliosis. Application of the Kaneda two-rod system
    • Kaneda K, Shono Y, Satoh S, Abumi K: New anterior instrumentation for the management of thoracolumbar and lumbar scoliosis. Application of the Kaneda two-rod system. Spine 21:1250-1262, 1996
    • (1996) Spine , vol.21 , pp. 1250-1262
    • Kaneda, K.1    Shono, Y.2    Satoh, S.3    Abumi, K.4
  • 9
    • 0037082597 scopus 로고    scopus 로고
    • Central and juxta-endplate vertebral body screw placement: A biomechanical analysis in a human cadaveric model
    • Lowe T, O'Brien M, Smith D, Fitzgerald D, Vraney R, Eule J, Alongi P: Central and juxta-endplate vertebral body screw placement: a biomechanical analysis in a human cadaveric model. Spine 27:369-373, 2002
    • (2002) Spine , vol.27 , pp. 369-373
    • Lowe, T.1    O'Brien, M.2    Smith, D.3    Fitzgerald, D.4    Vraney, R.5    Eule, J.6    Alongi, P.7
  • 10
    • 0022354031 scopus 로고
    • Biomechanical time-tolerance of fresh cadaveric human spine specimens
    • Panjabi MM, Krag M, Summers D, Videman T: Biomechanical time-tolerance of fresh cadaveric human spine specimens. J Orthop Res 3:292-300, 1985
    • (1985) J Orthop Res , vol.3 , pp. 292-300
    • Panjabi, M.M.1    Krag, M.2    Summers, D.3    Videman, T.4
  • 11
    • 3042811087 scopus 로고    scopus 로고
    • Biomechanical comparison of expandable cages for vertebral body replacement in the thoracolumbar spine
    • Pflugmacher R, Schleicher P, Schaefer J, Scholz M, Ludwig K, Khodadadyan-Klostermann C, et al: Biomechanical comparison of expandable cages for vertebral body replacement in the thoracolumbar spine. Spine 29:1413-1419, 2004
    • (2004) Spine , vol.29 , pp. 1413-1419
    • Pflugmacher, R.1    Schleicher, P.2    Schaefer, J.3    Scholz, M.4    Ludwig, K.5    Khodadadyan-Klostermann, C.6
  • 12
    • 0027300763 scopus 로고
    • A prospective, randomized study of lumbar fusion. Preliminary results
    • Zdeblick TA: A prospective, randomized study of lumbar fusion. Preliminary results. Spine 18:983-991, 1993
    • (1993) Spine , vol.18 , pp. 983-991
    • Zdeblick, T.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.