메뉴 건너뛰기




Volumn 14, Issue 3, 1999, Pages 153-165

A new technique for determining 3-D joint angles: The tilt/twist method

Author keywords

Attitude vector; Cardan angles; Coupling; Euler angles; Helical angles; Joint coordinate system

Indexed keywords

ANGLE MEASUREMENT; JOINTS (ANATOMY); VECTORS;

EID: 0033104984     PISSN: 02680033     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0268-0033(98)00080-1     Document Type: Article
Times cited : (143)

References (11)
  • 1
    • 16144366491 scopus 로고    scopus 로고
    • Methods for determining spinal flexion/extension, lateral bending, and axial rotation from marker coordinate data: Analysis and refinement
    • Crawford N.R., Yamaguchi G.T., Dickman C.A. Methods for determining spinal flexion/extension, lateral bending, and axial rotation from marker coordinate data: Analysis and refinement. Hum Mvmt Sci 1996;15:55-78.
    • (1996) Hum Mvmt Sci , vol.15 , pp. 55-78
    • Crawford, N.R.1    Yamaguchi, G.T.2    Dickman, C.A.3
  • 2
    • 0025939921 scopus 로고
    • Functional biomechanics of the spine
    • Smith T.J., Fernie G.R. Functional biomechanics of the spine. Spine 1991;16:1197-1203.
    • (1991) Spine , vol.16 , pp. 1197-1203
    • Smith, T.J.1    Fernie, G.R.2
  • 3
    • 0000882529 scopus 로고
    • Representation and calculation of 3-D joint movement
    • Woltring H.J. Representation and calculation of 3-D joint movement. Hum Mvmt Sci 1991;10:603-616.
    • (1991) Hum Mvmt Sci , vol.10 , pp. 603-616
    • Woltring, H.J.1
  • 4
    • 0020759032 scopus 로고
    • A joint coordinate system for the clinical description of three-dimensional motions: Application to the knee
    • Grood E.S., Suntay W.S. A joint coordinate system for the clinical description of three-dimensional motions: Application to the knee. J Biomech Eng 1983;105:136-144.
    • (1983) J Biomech Eng , vol.105 , pp. 136-144
    • Grood, E.S.1    Suntay, W.S.2
  • 5
    • 0020124120 scopus 로고
    • Movements of the lumbar spine measured by three-dimensional x-ray analysis
    • Pearcy M.J., Whittle M.W. Movements of the lumbar spine measured by three-dimensional x-ray analysis. J Biomed Eng 1982;4:107-112.
    • (1982) J Biomed Eng , vol.4 , pp. 107-112
    • Pearcy, M.J.1    Whittle, M.W.2
  • 6
    • 0027417508 scopus 로고
    • Examining motion in the cervical spine II: Characterization of coupled joint motion using an opto-electronic device to track skin markers
    • Roozmon P., Gracovetsky S.A., Gouw G.J., Newman N. Examining motion in the cervical spine II: Characterization of coupled joint motion using an opto-electronic device to track skin markers. J Biomed Eng 1993;15:13-22.
    • (1993) J Biomed Eng , vol.15 , pp. 13-22
    • Roozmon, P.1    Gracovetsky, S.A.2    Gouw, G.J.3    Newman, N.4
  • 7
    • 0028630402 scopus 로고
    • 3-D attitude representation of human joints: A standardization proposal
    • Woltring H.J. 3-D attitude representation of human joints: A standardization proposal. J Biomech 1994;27:1399-1414.
    • (1994) J Biomech , vol.27 , pp. 1399-1414
    • Woltring, H.J.1
  • 8
    • 0027627660 scopus 로고
    • Posture affects motion coupling patterns of the upper cervical spine
    • Panjabi M.M., Oda T., Crisco III J.J., Dvorák J., Grob D. Posture affects motion coupling patterns of the upper cervical spine. J Orthop Res 1993;11:525-536.
    • (1993) J Orthop Res , vol.11 , pp. 525-536
    • Panjabi, M.M.1    Oda, T.2    Crisco J.J. III3    Dvorák, J.4    Grob, D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.