메뉴 건너뛰기




Volumn 18, Issue 6, 2003, Pages

A biomechanical analysis of triangulation of anterior vertebral double-screw fixation

Author keywords

Anterior spinal device; Bi cortical; Biomechanical test; Triangulation; Uni cortical; Vertebral screw

Indexed keywords

BIOLOGICAL ORGANS; RISK ASSESSMENT; SCREWS; STRENGTH OF MATERIALS;

EID: 0038386765     PISSN: 02680033     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0268-0033(03)00083-4     Document Type: Conference Paper
Times cited : (13)

References (21)
  • 1
    • 0023006266 scopus 로고
    • An analysis of the results of Dwyer and Zielke instrumentations in the treatment of scoliosis
    • Bauer R., Mostegel A., Eichenauer M. An analysis of the results of Dwyer and Zielke instrumentations in the treatment of scoliosis. Arch. Orthop. Trauma Surg. 105:1986;302-309.
    • (1986) Arch. Orthop. Trauma Surg. , vol.105 , pp. 302-309
    • Bauer, R.1    Mostegel, A.2    Eichenauer, M.3
  • 3
    • 0021175745 scopus 로고
    • Anterior stabilization of thoracolumbar injuries
    • Dunn H.K. Anterior stabilization of thoracolumbar injuries. Clin. Orthop. 189:1984;116-124.
    • (1984) Clin. Orthop. , vol.189 , pp. 116-124
    • Dunn, H.K.1
  • 4
    • 0038402839 scopus 로고
    • Anterior instrumentation in scoliosis
    • Dwyer A.F. Anterior instrumentation in scoliosis. J. Bone Joint Surg. 52B:1970;782-787.
    • (1970) J. Bone Joint Surg. , vol.52 B , pp. 782-787
    • Dwyer, A.F.1
  • 5
    • 0027378841 scopus 로고
    • Relationship of vertebral bone screw axial pullout strength to quantitative tomographic trabecular bone mineral content
    • Gilbert S.G., Johns P.C., Chow D.C., Black R.C. Relationship of vertebral bone screw axial pullout strength to quantitative tomographic trabecular bone mineral content. J. Spinal Disord. 6:1993;513-521.
    • (1993) J. Spinal Disord. , vol.6 , pp. 513-521
    • Gilbert, S.G.1    Johns, P.C.2    Chow, D.C.3    Black, R.C.4
  • 7
    • 0030024429 scopus 로고    scopus 로고
    • Strength of fixation of the anterior vertebra body screw
    • Horton W.C., Blackstock S.F., Norman J.T. Strength of fixation of the anterior vertebra body screw. Spine. 21:1996;439-444.
    • (1996) Spine , vol.21 , pp. 439-444
    • Horton, W.C.1    Blackstock, S.F.2    Norman, J.T.3
  • 8
    • 0032818078 scopus 로고    scopus 로고
    • An unusual complication of anterior spinal instrumentation: Hemothorax contralateral to the side of the incision. A case report
    • Hsieh P.H., Chen W.J., Chen L.H., Niu C.C. An unusual complication of anterior spinal instrumentation: hemothorax contralateral to the side of the incision. A case report. J. Bone Joint Surg. 81A:1999;998-1001.
    • (1999) J. Bone Joint Surg. , vol.81 A , pp. 998-1001
    • Hsieh, P.H.1    Chen, W.J.2    Chen, L.H.3    Niu, C.C.4
  • 9
    • 0021743454 scopus 로고
    • Burst fractures with neurological deficits of the thoracolumbar spine: Results of the anterior decompression and stabilization with anterior instrumentation
    • Kaneda K., Abumi K., Fujiya M. Burst fractures with neurological deficits of the thoracolumbar spine: results of the anterior decompression and stabilization with anterior instrumentation. Spine. 9:1984;788-795.
    • (1984) Spine , vol.9 , pp. 788-795
    • Kaneda, K.1    Abumi, K.2    Fujiya, M.3
  • 10
    • 0023917304 scopus 로고
    • Anterior fixation of burst fractures of the thoracic and lumbar spine with or without neurological involvement
    • Kostuik J.P. Anterior fixation of burst fractures of the thoracic and lumbar spine with or without neurological involvement. Spine. 13:1988;286-293.
    • (1988) Spine , vol.13 , pp. 286-293
    • Kostuik, J.P.1
  • 11
    • 0022653406 scopus 로고
    • Techniques of internal fixation for degenerative conditions of the lumbar spine
    • Kostuik J.P., Errico T.J., Gleason T.F. Techniques of internal fixation for degenerative conditions of the lumbar spine. Clin. Orthop. 203:1986;219-231.
    • (1986) Clin. Orthop. , vol.203 , pp. 219-231
    • Kostuik, J.P.1    Errico, T.J.2    Gleason, T.F.3
  • 12
    • 0022634973 scopus 로고
    • An internal fixator for posterior application to short segments of the thoracic, lumbar, or lumbosacral spine: Design and testing
    • Krag M.H., Beynnon B.D., Pope M.H. An internal fixator for posterior application to short segments of the thoracic, lumbar, or lumbosacral spine: design and testing. Clin. Orthop. 203:1986;75-98.
    • (1986) Clin. Orthop. , vol.203 , pp. 75-98
    • Krag, M.H.1    Beynnon, B.D.2    Pope, M.H.3
  • 13
    • 0032522914 scopus 로고    scopus 로고
    • Anterior vertebral body screw pullout testing. A comparison of Zielke, Kaneda, universal spine system, and universal spine system with pullout-resistant nut
    • Lieberman I.H., Khazim R., Woodside T. Anterior vertebral body screw pullout testing. A comparison of Zielke, Kaneda, universal spine system, and universal spine system with pullout-resistant nut. Spine. 23:1998;908-910.
    • (1998) Spine , vol.23 , pp. 908-910
    • Lieberman, I.H.1    Khazim, R.2    Woodside, T.3
  • 14
    • 0028918045 scopus 로고
    • Strength of anterior vertebral screw fixation in relation to bone mineral density
    • Lim T.H., An H.S., Evanich C. Strength of anterior vertebral screw fixation in relation to bone mineral density. J. Spinal Disord. 8:1995;121-125.
    • (1995) J. Spinal Disord. , vol.8 , pp. 121-125
    • Lim, T.H.1    An, H.S.2    Evanich, C.3
  • 15
    • 0027366735 scopus 로고
    • Penetration of a screw into the thoracic aorta in anterior spinal instrumentation. A case report
    • Matsuzaki H., Tokuhashi Y., Wakabayashi K., Kitamura S. Penetration of a screw into the thoracic aorta in anterior spinal instrumentation. A case report. Spine. 18:1993;2327-2331.
    • (1993) Spine , vol.18 , pp. 2327-2331
    • Matsuzaki, H.1    Tokuhashi, Y.2    Wakabayashi, K.3    Kitamura, S.4
  • 16
    • 0030454240 scopus 로고    scopus 로고
    • Comparison between single-screw and triangulated, double-screw fixation in anterior spine surgery. A biomechanical test
    • Ogon M., Haid C., Krismer M., Sterzinger W., Bauer R. Comparison between single-screw and triangulated, double-screw fixation in anterior spine surgery. A biomechanical test. Spine. 21:1996;2728-2734.
    • (1996) Spine , vol.21 , pp. 2728-2734
    • Ogon, M.1    Haid, C.2    Krismer, M.3    Sterzinger, W.4    Bauer, R.5
  • 17
    • 0027365874 scopus 로고
    • Stability of transpedicle screwing for the osteoporotic spine: An in vitro study of mechanical stability
    • Okuyama K., Sato K., Abe E. Stability of transpedicle screwing for the osteoporotic spine: An in vitro study of mechanical stability. Spine. 18:1993;2240-2245.
    • (1993) Spine , vol.18 , pp. 2240-2245
    • Okuyama, K.1    Sato, K.2    Abe, E.3
  • 18
    • 0025801025 scopus 로고
    • Triangulation of pedicular instrumentation: A biomechanical analysis
    • Ruland C.M., McAfee P.C., Wareden K.E., Cunningham B.W. Triangulation of pedicular instrumentation: a biomechanical analysis. Spine. 16:1991;270-276.
    • (1991) Spine , vol.16 , pp. 270-276
    • Ruland, C.M.1    McAfee, P.C.2    Wareden, K.E.3    Cunningham, B.W.4
  • 19
    • 0029161957 scopus 로고
    • Predicting the integrity of vertebral bone screw fixation in anterior spinal instrumentation
    • Snyder B.D., Zaltz I., Hall J.E., Emans J.B. Predicting the integrity of vertebral bone screw fixation in anterior spinal instrumentation. Spine. 20:1995;1568-1574.
    • (1995) Spine , vol.20 , pp. 1568-1574
    • Snyder, B.D.1    Zaltz, I.2    Hall, J.E.3    Emans, J.B.4
  • 20
    • 0034319044 scopus 로고    scopus 로고
    • Anterior vertebral screw strain with and without solid interspace support
    • Spiegel D.A., Cunningham B.W., Oda I. Anterior vertebral screw strain with and without solid interspace support. Spine. 25:2000;2755-2761.
    • (2000) Spine , vol.25 , pp. 2755-2761
    • Spiegel, D.A.1    Cunningham, B.W.2    Oda, I.3
  • 21
    • 0023937351 scopus 로고
    • Early clinical experience with the Syracuse I-plate: An anterior spinal fixation device
    • Yuan H.A., Mann K.A., Found E.M. Early clinical experience with the Syracuse I-plate: an anterior spinal fixation device. Spine. 23:1988;278-285.
    • (1988) Spine , vol.23 , pp. 278-285
    • Yuan, H.A.1    Mann, K.A.2    Found, E.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.