메뉴 건너뛰기




Volumn 15, Issue 2, 2006, Pages 247-252

Eight-year results of freestyle stentless bioprostehsis in the aortic position: A single-center study of 500 patients

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; AORTA CLAMPING; AORTA VALVE DISEASE; AORTA VALVE PROSTHESIS; AORTA VALVE REPLACEMENT; ARTICLE; CARDIOPULMONARY BYPASS; CORONARY ARTERY BYPASS GRAFT; ELECTROCARDIOGRAM; ENDOCARDITIS; EXTRACORPOREAL CIRCULATION; FEMALE; FOLLOW UP; HEART VALVE BIOPROSTHESIS; HUMAN; MAJOR CLINICAL STUDY; MALE; MITRAL VALVE REPLACEMENT; OPERATION DURATION; OVERALL SURVIVAL; PRIORITY JOURNAL; REOPERATION; SHORT COURSE THERAPY; SURGICAL MORTALITY; SURGICAL TECHNIQUE; SURVIVAL RATE; TREATMENT INDICATION; TREATMENT OUTCOME;

EID: 33645565557     PISSN: 09668519     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (20)

References (25)
  • 1
    • 0029093740 scopus 로고
    • Perioperative assessment of aortic homograft, Toronto stentless valve, and stented valve in the aortic position
    • Jin XY, Gibson DG, Yacoub MH, Pepper JR. Perioperative assessment of aortic homograft, Toronto stentless valve, and stented valve in the aortic position. Ann Thorac Surg 1995;60(Suppl.):S395-S401
    • (1995) Ann Thorac Surg , vol.60 , Issue.SUPPL.
    • Jin, X.Y.1    Gibson, D.G.2    Yacoub, M.H.3    Pepper, J.R.4
  • 2
    • 0032311005 scopus 로고    scopus 로고
    • Comparison of exercise hemodynamics among nonstented aortic bioprostheses, mechanical valves and normal native aortic valves
    • Silberman S, Shaheen J, Fink D, et al. Comparison of exercise hemodynamics among nonstented aortic bioprostheses, mechanical valves and normal native aortic valves. J Card Surg 1998;13:412-416
    • (1998) J Card Surg , vol.13 , pp. 412-416
    • Silberman, S.1    Shaheen, J.2    Fink, D.3
  • 3
    • 0034109387 scopus 로고    scopus 로고
    • Comparative rest and exercise hemodynamics of 23 mm stentless versus 23 mm stented aortic bioprostheses
    • Fries R, Wendler O, Shieffer H, Schafers HJ. Comparative rest and exercise hemodynamics of 23 mm stentless versus 23 mm stented aortic bioprostheses. Ann Thorac Surg 2000;69:817-822
    • (2000) Ann Thorac Surg , vol.69 , pp. 817-822
    • Fries, R.1    Wendler, O.2    Shieffer, H.3    Schafers, H.J.4
  • 5
    • 0027390272 scopus 로고
    • Effects of fixation back pressure and antimineralization treatment on the morphology of porcine aortic bioprosthetic valves
    • Flomenbaum MA, Schoen FJ. Effects of fixation back pressure and antimineralization treatment on the morphology of porcine aortic bioprosthetic valves. J Thorac Cardiovasc Surg 1993;105:154-164
    • (1993) J Thorac Cardiovasc Surg , vol.105 , pp. 154-164
    • Flomenbaum, M.A.1    Schoen, F.J.2
  • 6
    • 0028235034 scopus 로고
    • Porcine heart valves: Mechanism of efficacy of 2-amino oleic acid for inhibition of calcification of glutaraldehyde-pretreated porcine bioprosthetic valves
    • Chen W, Schoen FJ, Levy RJ. Porcine heart valves: Mechanism of efficacy of 2-amino oleic acid for inhibition of calcification of glutaraldehyde-pretreated porcine bioprosthetic valves. Circulation 1994;90:323-329
    • (1994) Circulation , vol.90 , pp. 323-329
    • Chen, W.1    Schoen, F.J.2    Levy, R.J.3
  • 7
    • 0033797772 scopus 로고    scopus 로고
    • Survival advantage of stentless aortic bioprostheses
    • Westaby S, Horton M, Jin XY, et al. Survival advantage of stentless aortic bioprostheses. Ann Thorac Surg 2000;70:785-790
    • (2000) Ann Thorac Surg , vol.70 , pp. 785-790
    • Westaby, S.1    Horton, M.2    Jin, X.Y.3
  • 8
    • 0036803163 scopus 로고    scopus 로고
    • Reduction of the inflammatory response following coronary bypass grafting with total minimal extracorporeal circulation
    • Fromes Y, Gaillard D, Ponzio O, et al. Reduction of the inflammatory response following coronary bypass grafting with total minimal extracorporeal circulation. Eur J Cardiothorac Surg 2002;22:527-533
    • (2002) Eur J Cardiothorac Surg , vol.22 , pp. 527-533
    • Fromes, Y.1    Gaillard, D.2    Ponzio, O.3
  • 10
    • 0032451626 scopus 로고    scopus 로고
    • Carpentier-Edwards standard porcine bioprosthesis: A 21-year experience
    • Jamieson WRE, Burr LH, Munro AI, Miyagishima RT. Carpentier-Edwards standard porcine bioprosthesis: A 21-year experience. Ann Thorac Surg 1998;66(Suppl.):S40-S43
    • (1998) Ann Thorac Surg , vol.66 , Issue.SUPPL.
    • Jamieson, W.R.E.1    Burr, L.H.2    Munro, A.I.3    Miyagishima, R.T.4
  • 11
    • 0034774317 scopus 로고    scopus 로고
    • Exercise hemodynamics of aortic prostheses: Comparison between stentless bioprostheses and mechanical valves
    • Silberman S, Shaheen J, Merin O, et al. Exercise hemodynamics of aortic prostheses: Comparison between stentless bioprostheses and mechanical valves. Ann Thorac Surg 2001;72:1217-1221
    • (2001) Ann Thorac Surg , vol.72 , pp. 1217-1221
    • Silberman, S.1    Shaheen, J.2    Merin, O.3
  • 12
    • 0026942532 scopus 로고
    • Aortic valve replacement with the Toronto SPV bioprosthesis
    • David TE, Bos J, Rakowski H. Aortic valve replacement with the Toronto SPV bioprosthesis. J Heart Valve Dis 1992;1:244-248
    • (1992) J Heart Valve Dis , vol.1 , pp. 244-248
    • David, T.E.1    Bos, J.2    Rakowski, H.3
  • 13
    • 0036210963 scopus 로고    scopus 로고
    • Aortic valve replacement with the Toronto SPV: Long-term clinical and hemodynamic results
    • Dellgren G, Feindel CM, Bos J, Ivanov J, David TE. Aortic valve replacement with the Toronto SPV: Long-term clinical and hemodynamic results. Eur J Cardiothorac Surg 2002;21:698-702
    • (2002) Eur J Cardiothorac Surg , vol.21 , pp. 698-702
    • Dellgren, G.1    Feindel, C.M.2    Bos, J.3    Ivanov, J.4    David, T.E.5
  • 14
    • 9344264599 scopus 로고    scopus 로고
    • Long term results of aortic valve replacement with the St. Jude Toronto stentless porcine valve
    • Desai ND, Merin O, Cohen GN, et al. Long term results of aortic valve replacement with the St. Jude Toronto stentless porcine valve. Ann Thorac Surg 2004;78:2076-2083
    • (2004) Ann Thorac Surg , vol.78 , pp. 2076-2083
    • Desai, N.D.1    Merin, O.2    Cohen, G.N.3
  • 15
    • 0031844254 scopus 로고    scopus 로고
    • Aortic valve replacement with stentless and stented porcine valves: A case-match study
    • David TE, Puschman R, Ivanov J, et al. Aortic valve replacement with stentless and stented porcine valves: A case-match study. J Thorac Cardiovasc Surg 1998;116:236-241
    • (1998) J Thorac Cardiovasc Surg , vol.116 , pp. 236-241
    • David, T.E.1    Puschman, R.2    Ivanov, J.3
  • 16
    • 0035002811 scopus 로고    scopus 로고
    • Tissue characterization and calcification potential of commercial bioprosthetic heart valves
    • Cunanan CM, Cabiling CM, Dinh TT, et al. Tissue characterization and calcification potential of commercial bioprosthetic heart valves. Ann Thorac Surg 2001;71(Suppl.):S417-S421
    • (2001) Ann Thorac Surg , vol.71 , Issue.SUPPL.
    • Cunanan, C.M.1    Cabiling, C.M.2    Dinh, T.T.3
  • 17
    • 0036260278 scopus 로고    scopus 로고
    • Eight-year results of aortic root replacement with the Freestyle stentless porcine aortic root bioprosthesis
    • Kon ND, Riley RD, Adair SM, Kitzman DW, Cordell AR. Eight-year results of aortic root replacement with the Freestyle stentless porcine aortic root bioprosthesis. Ann Thorac Surg 2002;73:1817-1821
    • (2002) Ann Thorac Surg , vol.73 , pp. 1817-1821
    • Kon, N.D.1    Riley, R.D.2    Adair, S.M.3    Kitzman, D.W.4    Cordell, A.R.5
  • 18
    • 0018104133 scopus 로고
    • The problem of valve prosthesis-patient mismatch
    • Rahimtoola SH. The problem of valve prosthesis-patient mismatch. Circulation 1978;58:20-24
    • (1978) Circulation , vol.58 , pp. 20-24
    • Rahimtoola, S.H.1
  • 19
    • 0034619384 scopus 로고    scopus 로고
    • Prosthesis-patient mismatch affects survival after aortic valve replacement
    • Rao V, Jamieson WRE, Ivanov J, Armstrong S, David TE. Prosthesis-patient mismatch affects survival after aortic valve replacement. Circulation 2000;102(Suppl.):III5-III9
    • (2000) Circulation , vol.102 , Issue.SUPPL.
    • Rao, V.1    Jamieson, W.R.E.2    Ivanov, J.3    Armstrong, S.4    David, T.E.5
  • 20
    • 0042859863 scopus 로고    scopus 로고
    • Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement
    • Blais C, Dumesnil JG, Baillot R, Simard S, Doyle D, Pibarot P. Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement. Circulation 2003;180:983-988
    • (2003) Circulation , vol.180 , pp. 983-988
    • Blais, C.1    Dumesnil, J.G.2    Baillot, R.3    Simard, S.4    Doyle, D.5    Pibarot, P.6
  • 22
    • 0029825730 scopus 로고    scopus 로고
    • Small aortic root in the elderly: Use of stentless bioprosthesis
    • Sintek CF. Small aortic root in the elderly: Use of stentless bioprosthesis. J Heart Valve Dis 1996;5(Suppl.III):S308-S313
    • (1996) J Heart Valve Dis , vol.5 , Issue.SUPPL. III
    • Sintek, C.F.1
  • 23
    • 0033965913 scopus 로고    scopus 로고
    • A quantitative study of calcium deposition in the aortic wall following Medtronic Freestyle compared with homograft aortic root replacement. A prospective randomized trial
    • Melina G, Rubens MB, Birks EJ, Bizzarri F, Khagani A, Yacoub MH. A quantitative study of calcium deposition in the aortic wall following Medtronic Freestyle compared with homograft aortic root replacement. A prospective randomized trial. J Heart Valve Dis 2000;9:97-103
    • (2000) J Heart Valve Dis , vol.9 , pp. 97-103
    • Melina, G.1    Rubens, M.B.2    Birks, E.J.3    Bizzarri, F.4    Khagani, A.5    Yacoub, M.H.6
  • 25
    • 0036797557 scopus 로고    scopus 로고
    • Impact of implant technique following Freestyle stentless aortic valve replacement
    • the Freestyle Valve Study Group
    • Bach DS, Cartier PC, Kon ND and the Freestyle Valve Study Group. Impact of implant technique following Freestyle stentless aortic valve replacement. Ann Thorac Surg 2002;74:1107-1113
    • (2002) Ann Thorac Surg , vol.74 , pp. 1107-1113
    • Bach, D.S.1    Cartier, P.C.2    Kon, N.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.