-
1
-
-
0027221180
-
Long-term results of Charnley low-friction arthroplasty in young patients
-
Joshi, A. B., Porter, M. L., Trail, I. A., Hunt, L. P., Murphy, J. C., and Hardinge, K. Long-term results of Charnley low-friction arthroplasty in young patients. J. Bone Jt Surg., 1993, 75B, 616-623.
-
(1993)
J. Bone Jt Surg.
, vol.75 B
, pp. 616-623
-
-
Joshi, A.B.1
Porter, M.L.2
Trail, I.A.3
Hunt, L.P.4
Murphy, J.C.5
Hardinge, K.6
-
2
-
-
0028139402
-
Long-term results of cemented total hip arthroplasty in patients 45 years old or younger. A 16-year follow-up study
-
Dorr, L. D, Kane, T. J., and Conaty, J. P. Long-term results of cemented total hip arthroplasty in patients 45 years old or younger. A 16-year follow-up study. J. Arthroplasty, 1994, 9, 453-456.
-
(1994)
J. Arthroplasty
, vol.9
, pp. 453-456
-
-
Dorr, L.D.1
Kane, T.J.2
Conaty, J.P.3
-
3
-
-
0025325377
-
Resurfacing hip arthroplasty: Classification of loosening and the role of prosthesis wear particles
-
Howie, D. W., Cornish, B. L., and Vernon-Roberts, B. Resurfacing hip arthroplasty: Classification of loosening and the role of prosthesis wear particles. Clin. Orthop., 1990, 255, 144-159.
-
(1990)
Clin. Orthop.
, vol.255
, pp. 144-159
-
-
Howie, D.W.1
Cornish, B.L.2
Vernon-Roberts, B.3
-
4
-
-
0029882821
-
Long-duration metal-on-metal total hip arthroplasties with low wear of the articulating surfaces
-
Schmalzried, T. P., Peters, P. C., Maurer, B. T., Bragdon, C. R., and Harris, W. H. Long-duration metal-on-metal total hip arthroplasties with low wear of the articulating surfaces. J. Arthroplasty, 1996, 11, 322-331.
-
(1996)
J. Arthroplasty
, vol.11
, pp. 322-331
-
-
Schmalzried, T.P.1
Peters, P.C.2
Maurer, B.T.3
Bragdon, C.R.4
Harris, W.H.5
-
5
-
-
1642404356
-
Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis
-
Daniel, J., Pynsent, P. B., and McMinn, D. J. Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis. J. Bone Jt Surg., 2004, 86B, 177-184.
-
(2004)
J. Bone Jt Surg.
, vol.86 B
, pp. 177-184
-
-
Daniel, J.1
Pynsent, P.B.2
McMinn, D.J.3
-
6
-
-
14144256752
-
Birmingham hip resurfacing arthroplasty. A minimum follow-up of five years
-
Treacy, R. B., McBryde, C. W., and Pynsent, P. B. Birmingham hip resurfacing arthroplasty. A minimum follow-up of five years. J. Bone Jt Surg., 2005, 87B, 167-170.
-
(2005)
J. Bone Jt Surg.
, vol.87 B
, pp. 167-170
-
-
Treacy, R.B.1
McBryde, C.W.2
Pynsent, P.B.3
-
7
-
-
15044348747
-
Early results of primary Birmingham hip resurfacings. An independent prospective study of the first 230 hips
-
Back, D. L., Dalziel, R., Young, D., and Shimmin, A. Early results of primary Birmingham hip resurfacings. An independent prospective study of the first 230 hips. J. Bone Jt Surg., 2005, 87B, 324-329.
-
(2005)
J. Bone Jt Surg.
, vol.87 B
, pp. 324-329
-
-
Back, D.L.1
Dalziel, R.2
Young, D.3
Shimmin, A.4
-
8
-
-
9644266666
-
Metal-on-metal surface arthroplasty with a cemented femoral component: A 7-10 year follow-up study
-
Beaule, P. E., Le Duff, M., Campbell, P., Dorey, F. J., Park, S. H., and Amstutz, H. C. Metal-on-metal surface arthroplasty with a cemented femoral component: A 7-10 year follow-up study. J. Arthroplasty, 2004, 19(8), Suppl. 3, 17-22.
-
(2004)
J. Arthroplasty
, vol.19
, Issue.8 SUPPL. 3
, pp. 17-22
-
-
Beaule, P.E.1
Le Duff, M.2
Campbell, P.3
Dorey, F.J.4
Park, S.H.5
Amstutz, H.C.6
-
9
-
-
14044270106
-
Stability of the Birmingham hip resurfacing arthroplasty at two years. A radiostereophotogrammetric analysis study
-
Itayem, R., Arndt, A., Nistor, L., McMinn, D., and Lundberg, A. Stability of the Birmingham hip resurfacing arthroplasty at two years. A radiostereophotogrammetric analysis study. J. Bone Jt Surg., 2005, 87B, 158-162.
-
(2005)
J. Bone Jt Surg.
, vol.87 B
, pp. 158-162
-
-
Itayem, R.1
Arndt, A.2
Nistor, L.3
McMinn, D.4
Lundberg, A.5
-
10
-
-
18944393953
-
EBRA-FCA for measurement of migration of the femoral component in surface arthroplasty of the hip
-
Beaule, P. E., Krismer, M., Mayrhofer, P., Wanner, S., Le Duff, M., Mattesich, M., Stoeckl, B., Amstutz, H. C., and Biedermann, R. EBRA-FCA for measurement of migration of the femoral component in surface arthroplasty of the hip. J. Bone Jt Surg., 2005, 87B, 741-744.
-
(2005)
J. Bone Jt Surg.
, vol.87 B
, pp. 741-744
-
-
Beaule, P.E.1
Krismer, M.2
Mayrhofer, P.3
Wanner, S.4
Le Duff, M.5
Mattesich, M.6
Stoeckl, B.7
Amstutz, H.C.8
Biedermann, R.9
-
11
-
-
0348223830
-
Metal-on-metal hybrid surface arthroplasty: Two- to six-year follow-up study
-
Amstutz, H. C., Beaule, P. E., Dorey, F. J., Le Duff, M. J., Campbell, P.A., and Gruen, T. A. Metal-on-metal hybrid surface arthroplasty: Two- to six-year follow-up study. J. Bone Jt Surg., 2004, 86A, 28-39.
-
(2004)
J. Bone Jt Surg.
, vol.86 A
, pp. 28-39
-
-
Amstutz, H.C.1
Beaule, P.E.2
Dorey, F.J.3
Le Duff, M.J.4
Campbell, P.A.5
Gruen, T.A.6
-
12
-
-
11044235542
-
Preservation of bone mineral density of the proximal femur following hemisurface arthroplasty
-
Amstutz, H. C., Ebramzadeh, E., Sarkany, A., Le Duff, M., and Rude, R. Preservation of bone mineral density of the proximal femur following hemisurface arthroplasty. Orthopedics, 2004, 27, 1266-1271.
-
(2004)
Orthopedics
, vol.27
, pp. 1266-1271
-
-
Amstutz, H.C.1
Ebramzadeh, E.2
Sarkany, A.3
Le Duff, M.4
Rude, R.5
-
13
-
-
17744365971
-
Femoral neck fractures following Birmingham hip resurfacing
-
Shimmin, A. J. and Back. D. Femoral neck fractures following Birmingham hip resurfacing. J. Bone Jt Surg., 2005, 87B, 463-464.
-
(2005)
J. Bone Jt Surg.
, vol.87 B
, pp. 463-464
-
-
Shimmin, A.J.1
Back, D.2
-
14
-
-
0018970317
-
The optimum pore size for the fixation of porous-surfaced metal implants by the ingrowth of bone
-
Bobyn, J. D., Pillard, R. M., Cameron, H. U., and Weatherly, G. The optimum pore size for the fixation of porous-surfaced metal implants by the ingrowth of bone. Clin. Orthop., 1980, 150, 263-270.
-
(1980)
Clin. Orthop.
, vol.150
, pp. 263-270
-
-
Bobyn, J.D.1
Pillard, R.M.2
Cameron, H.U.3
Weatherly, G.4
-
15
-
-
0035186245
-
Long-term results using the anatomic medullary locking hip prosthesis
-
Engh, C. A. Jr, Claus, A. M., and Hopper, R. H, Jr. Long-term results using the anatomic medullary locking hip prosthesis. Clin. Orthop., 2001, 393, 137-146.
-
(2001)
Clin. Orthop.
, vol.393
, pp. 137-146
-
-
Engh Jr., C.A.1
Claus, A.M.2
Hopper Jr., R.H.3
-
16
-
-
5344263765
-
Long-term porous-coated cup survivorship using spikes, screws, and press-fitting for initial fixation
-
Engh, C. A., Hopper, R. H., and Engh, C. A. Jr. Long-term porous-coated cup survivorship using spikes, screws, and press-fitting for initial fixation. J. Arthroplasty, 2004, 19(7), Suppl. 2, 54-60.
-
(2004)
J. Arthroplasty
, vol.19
, Issue.7 SUPPL. 2
, pp. 54-60
-
-
Engh, C.A.1
Hopper, R.H.2
Engh Jr., C.A.3
-
17
-
-
0028874284
-
The effect of operative fit and hydroxyapatite coating on the mechanical and biological response to porous implants
-
Dalton, J. E., Cook, S. D., Thomas, K. A., and Kay, J. F. The effect of operative fit and hydroxyapatite coating on the mechanical and biological response to porous implants. J. Bone Jt Surg., 1995, 77A, 97-110.
-
(1995)
J. Bone Jt Surg.
, vol.77 A
, pp. 97-110
-
-
Dalton, J.E.1
Cook, S.D.2
Thomas, K.A.3
Kay, J.F.4
-
18
-
-
0027381478
-
Hydroxyapatite ceramic coating for bone implant fixation: Mechanical and histological studies in dogs
-
Soballe, K. Hydroxyapatite ceramic coating for bone implant fixation: mechanical and histological studies in dogs. Acta Orthop. Scand., 1993, 225, Suppl., 1-58.
-
(1993)
Acta Orthop. Scand.
, vol.225
, Issue.SUPPL.
, pp. 1-58
-
-
Soballe, K.1
-
19
-
-
0026832935
-
Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions
-
Soballe, K., Hansen, E. S., Brockstedt-Rassmussen, H., Jorgensen, P. H., and Bunger, C. Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions. J. Orthop. Res., 1992, 10, 285-299.
-
(1992)
J. Orthop. Res.
, vol.10
, pp. 285-299
-
-
Soballe, K.1
Hansen, E.S.2
Brockstedt-Rassmussen, H.3
Jorgensen, P.H.4
Bunger, C.5
-
20
-
-
0029870888
-
Hydroxyapatite coating of an acetabular prosthesis: Effect on stability
-
Moilanen, T., Stocks, G. W., Freeman, M. A., Scott, G., Goodier, W. D., and Evans, S. J. Hydroxyapatite coating of an acetabular prosthesis: effect on stability. J. Bone Jt Surg., 1996, 78B, 200-205.
-
(1996)
J. Bone Jt Surg.
, vol.78 B
, pp. 200-205
-
-
Moilanen, T.1
Stocks, G.W.2
Freeman, M.A.3
Scott, G.4
Goodier, W.D.5
Evans, S.J.6
-
21
-
-
0026908619
-
Hydroxyapatite coating of porous implants improves bone ingrowth and interface attachment strength
-
Cook, S. D., Thomas, K. A., Dalton, J. E., Volkman, T. K., Whitecloud, T. S., and Kay, J. F. Hydroxyapatite coating of porous implants improves bone ingrowth and interface attachment strength. J. Biomed. Mater. Res., 1992, 26, 989-1001.
-
(1992)
J. Biomed. Mater. Res.
, vol.26
, pp. 989-1001
-
-
Cook, S.D.1
Thomas, K.A.2
Dalton, J.E.3
Volkman, T.K.4
Whitecloud, T.S.5
Kay, J.F.6
-
22
-
-
0036787718
-
Cementless total hip arthroplasty with a close proximal fit and short tapered distal stem (third-generation) prosthesis
-
Kim, Y. H. Cementless total hip arthroplasty with a close proximal fit and short tapered distal stem (third-generation) prosthesis. J. Arthroplasty, 2002, 17, 841-850.
-
(2002)
J. Arthroplasty
, vol.17
, pp. 841-850
-
-
Kim, Y.H.1
-
23
-
-
0028361826
-
The Harris-Galante porous (HGP) acetabular component press-fit without screw fixation: Five-year radiographic analysis of primary cases
-
Schmalzried, T. P., Wessinger, S. A., Hill, G. E., and Harris, W. H. The Harris-Galante porous (HGP) acetabular component press-fit without screw fixation: Five-year radiographic analysis of primary cases. J. Arthroplasty, 1994, 9, 235-242.
-
(1994)
J. Arthroplasty
, vol.9
, pp. 235-242
-
-
Schmalzried, T.P.1
Wessinger, S.A.2
Hill, G.E.3
Harris, W.H.4
-
24
-
-
0026442786
-
The Harris-Galante porous-coated acetabular component with screw fixation: Radiographic analysis of eighty-three primary hip replacements at a minimum of five years
-
Schmalzried, T. P. and Harris, W. H. The Harris-Galante porous-coated acetabular component with screw fixation: Radiographic analysis of eighty-three primary hip replacements at a minimum of five years. J. Bone Jt Surg., 1992, 74A, 1130-1139.
-
(1992)
J. Bone Jt Surg.
, vol.74 A
, pp. 1130-1139
-
-
Schmalzried, T.P.1
Harris, W.H.2
-
25
-
-
0034333770
-
Interfacial conditions between a press-fit acetabular cup and bone during daily activities: Implications for achieving bone in-growth
-
Spears, I. R., Pfleiderer, M., Schneider, E., Hille, E., Bergmann, G., and Morlock, M. M. Interfacial conditions between a press-fit acetabular cup and bone during daily activities: Implications for achieving bone in-growth. J. Biomechanics, 2000, 33, 1471-1477.
-
(2000)
J. Biomechanics
, vol.33
, pp. 1471-1477
-
-
Spears, I.R.1
Pfleiderer, M.2
Schneider, E.3
Hille, E.4
Bergmann, G.5
Morlock, M.M.6
-
26
-
-
0035217725
-
The effect of interfacial parameters on cup-bone relative micromotions. A finite element investigation
-
Spears, I. R., Pfleiderer, M., Schneider, E., Hille, E., and Morlock, M. M. The effect of interfacial parameters on cup-bone relative micromotions. A finite element investigation. J. Biomechanics, 2001, 34, 113-120.
-
(2001)
J. Biomechanics
, vol.34
, pp. 113-120
-
-
Spears, I.R.1
Pfleiderer, M.2
Schneider, E.3
Hille, E.4
Morlock, M.M.5
-
27
-
-
33645232928
-
Deformation of press-fitted metallic resurfacing cups. Part 1: Experimental simulation
-
Jin, Z. M., Meakins, S., Morlock, M. M., Parsons, P., Hardaker, C., Flett, M., and Isaac, G. Deformation of press-fitted metallic resurfacing cups. Part 1: Experimental simulation. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 2006, 220(H2), 299-309.
-
(2006)
Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine
, vol.220
, Issue.H2
, pp. 299-309
-
-
Jin, Z.M.1
Meakins, S.2
Morlock, M.M.3
Parsons, P.4
Hardaker, C.5
Flett, M.6
Isaac, G.7
-
28
-
-
0028198810
-
The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis
-
Schmalzried, T. P., Guttmann, D., Grecula, M., and Amstutz, H. C. The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis. J. Bone Jt Surg., 1994, 76A, 677-688.
-
(1994)
J. Bone Jt Surg.
, vol.76 A
, pp. 677-688
-
-
Schmalzried, T.P.1
Guttmann, D.2
Grecula, M.3
Amstutz, H.C.4
-
29
-
-
0031855096
-
Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration
-
Kennedy, J. G., Rogers, W. B., Soffe, K. E., Sullivan, R. J., Griffen, D. G., and Sheehan, L. J. Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration. J. Arthroplasty, 1998, 13, 530-534.
-
(1998)
J. Arthroplasty
, vol.13
, pp. 530-534
-
-
Kennedy, J.G.1
Rogers, W.B.2
Soffe, K.E.3
Sullivan, R.J.4
Griffen, D.G.5
Sheehan, L.J.6
-
30
-
-
0034524599
-
The evolution of ceramics in total hip replacement
-
Willmann, G. The evolution of ceramics in total hip replacement. Hip Int., 2000, 10, 193-203.
-
(2000)
Hip Int.
, vol.10
, pp. 193-203
-
-
Willmann, G.1
-
31
-
-
0033775536
-
Wear of alumina-on-alumina total hip arthroplasties at a mean 11-year followup
-
Prudhommeaux, F., Hamadouche, M., Nevelos, J., Doyle, C., Meunier, A., and Sedel, L. Wear of alumina-on-alumina total hip arthroplasties at a mean 11-year followup. Clin. Orthop., 2000, 379, 113-122.
-
(2000)
Clin. Orthop.
, vol.379
, pp. 113-122
-
-
Prudhommeaux, F.1
Hamadouche, M.2
Nevelos, J.3
Doyle, C.4
Meunier, A.5
Sedel, L.6
-
32
-
-
0032949430
-
Analysis of 118 second-generation metal-on-metal retrieved hip implants
-
Sleber, H.-P., Rieker, C. B., and Kottig, P. Analysis of 118 second-generation metal-on-metal retrieved hip implants. J. Bone Jt Surg., 1998, 80B, 46-50.
-
(1998)
J. Bone Jt Surg.
, vol.80 B
, pp. 46-50
-
-
Sleber, H.-P.1
Rieker, C.B.2
Kottig, P.3
-
33
-
-
9644279533
-
Cup inclination and serum concentration of cobalt and chromium after metal-on-metal total hip arthroplasty
-
Brodner, W., Grubl, A., Jankovsky, R., Meisinger, V., Lehr, S., and Gottsauner-Wolt, F. Cup inclination and serum concentration of cobalt and chromium after metal-on-metal total hip arthroplasty. J. Arthroplasty, 2004, 19(8), Suppl. 3, 66-70.
-
(2004)
J. Arthroplasty
, vol.19
, Issue.8 SUPPL. 3
, pp. 66-70
-
-
Brodner, W.1
Grubl, A.2
Jankovsky, R.3
Meisinger, V.4
Lehr, S.5
Gottsauner-Wolt, F.6
-
34
-
-
0027435276
-
A clinical, radiographic, and biomechanical study of the TARA prosthesis
-
de Waal Malefijt, M. C. and Huiskes, R. A clinical, radiographic, and biomechanical study of the TARA prosthesis. Arch. Orthop. Trauma Surg., 1993, 112, 220-225.
-
(1993)
Arch. Orthop. Trauma Surg.
, vol.112
, pp. 220-225
-
-
de Waal Malefijt, M.C.1
Huiskes, R.2
-
35
-
-
85047691712
-
Finite element analysis of the resurfaced femoral head
-
Taylor, M. Finite element analysis of the resurfaced femoral head. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 2006, 220(H2), 289-297.
-
(2006)
Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine
, vol.220
, Issue.H2
, pp. 289-297
-
-
Taylor, M.1
-
36
-
-
4544312502
-
Fracture of the neck of the femur after surface arthroplasty of the hip
-
Amstutz, H. C., Campbell, P. A., and Le Duff, M. J. Fracture of the neck of the femur after surface arthroplasty of the hip. J. Bone Jt Surg., 2004, 86A, 1874-1877.
-
(2004)
J. Bone Jt Surg.
, vol.86 A
, pp. 1874-1877
-
-
Amstutz, H.C.1
Campbell, P.A.2
Le Duff, M.J.3
-
37
-
-
33645236921
-
Biomechanical, morphological, and histological anadysis of early failures in hip resurfacing arthroplasty
-
Morlock, M. M., Bishop, N., Hahn, M., Ruther, W., and Delling, G. Biomechanical, morphological, and histological anadysis of early failures in hip resurfacing arthroplasty. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 2006, 220(H2), 333-344.
-
(2006)
Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine
, vol.220
, Issue.H2
, pp. 333-344
-
-
Morlock, M.M.1
Bishop, N.2
Hahn, M.3
Ruther, W.4
Delling, G.5
-
38
-
-
0021322281
-
Systemic effects of biomaterials
-
Black, J. Systemic effects of biomaterials. Biomaterials, 1984, 5, 11-18.
-
(1984)
Biomaterials
, vol.5
, pp. 11-18
-
-
Black, J.1
-
39
-
-
11844293972
-
Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints
-
Willert, H.-G., Buchhorn, G. H., Fayyazi, A., Flury, R., Windler, M., Koster, G., and Lohmann, C. H. Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. J. Bone Jt Surg., 2005, 87, 28-36.
-
(2005)
J. Bone Jt Surg.
, vol.87
, pp. 28-36
-
-
Willert, H.-G.1
Buchhorn, G.H.2
Fayyazi, A.3
Flury, R.4
Windler, M.5
Koster, G.6
Lohmann, C.H.7
-
40
-
-
0030627631
-
Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus
-
Jin, Z. M., Dowson, D., and Fisher, J. Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 1996, 211, 247-256.
-
(1996)
Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine
, vol.211
, pp. 247-256
-
-
Jin, Z.M.1
Dowson, D.2
Fisher, J.3
-
41
-
-
0042021516
-
A tribological study of cobalt chrome molybdenum alloys used in metal-on-metal resurfacing hip arthroplasty
-
Cawley, J., Metcalf, J. E. P., Jones, A. H., Band, T. J., and Skupien, D. S. A tribological study of cobalt chrome molybdenum alloys used in metal-on-metal resurfacing hip arthroplasty. Wear, 2003, 255, 999-1006.
-
(2003)
Wear
, vol.255
, pp. 999-1006
-
-
Cawley, J.1
Metcalf, J.E.P.2
Jones, A.H.3
Band, T.J.4
Skupien, D.S.5
-
42
-
-
9744251882
-
Development of metal/metal hip resurfacing
-
McMinn, D. J. W. Development of metal/metal hip resurfacing. Hip Int., 2003, 13, Suppl. 2, S41-S53.
-
(2003)
Hip Int.
, vol.13
, Issue.SUPPL. 2
-
-
McMinn, D.J.W.1
-
43
-
-
0033256670
-
Wear and lubrication of metal-on-metal hip implants
-
Chan, F. W., Bobyn, J. D., Medley, J. B., Krygier, J. J., and Tanzer, M. Wear and lubrication of metal-on-metal hip implants. Clin. Orthop., 1999, 369, 10-24.
-
(1999)
Clin. Orthop.
, vol.369
, pp. 10-24
-
-
Chan, F.W.1
Bobyn, J.D.2
Medley, J.B.3
Krygier, J.J.4
Tanzer, M.5
-
44
-
-
17044404373
-
Do heat treatments influence the wear of large diameter metal-on-metal hip joints? An in vitro study under normal and adverse conditions
-
New Orleans, Louisiana, USA, 2-5 February
-
Bowsher, J. G., Nevelos, J., Pickard, J., and Shelton, J. C. Do heat treatments influence the wear of large diameter metal-on-metal hip joints? An in vitro study under normal and adverse conditions. Transactions of the 49th Annual Meeting of the Orthopaedic Research Society, New Orleans, Louisiana, USA, 2-5 February 2003, p. 1398.
-
(2003)
Transactions of the 49th Annual Meeting of the Orthopaedic Research Society
, pp. 1398
-
-
Bowsher, J.G.1
Nevelos, J.2
Pickard, J.3
Shelton, J.C.4
-
45
-
-
9644287859
-
A hip joint simulator study of the performance of metal-on-metal joints. Part I: The role of materials
-
Dowson, D., Hardaker, C., Flett, M., and Isaac, G. H. A hip joint simulator study of the performance of metal-on-metal joints. Part I: The role of materials. J. Arthroplasty, 2004, 19(8), Suppl. 3, 118-123.
-
(2004)
J. Arthroplasty
, vol.19
, Issue.8 SUPPL. 3
, pp. 118-123
-
-
Dowson, D.1
Hardaker, C.2
Flett, M.3
Isaac, G.H.4
-
46
-
-
0035736451
-
The wear of metal-on-metal total hip prostheses measured in a hip simulator
-
Scholes, S. C., Green, S. M., and Unsworth, A. The wear of metal-on-metal total hip prostheses measured in a hip simulator. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 2001, 215, 523-530.
-
(2001)
Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine
, vol.215
, pp. 523-530
-
-
Scholes, S.C.1
Green, S.M.2
Unsworth, A.3
-
47
-
-
9644273921
-
A hip joint simulator study of the performance of metal-on-metal joints. Part II: Design
-
Dowson, D., Hardaker, C., Flett, M., and Isaac, G. H. A hip joint simulator study of the performance of metal-on-metal joints. Part II: design. J. Arthroplasty, 2004, 19(8), Suppl. 3, 124-130.
-
(2004)
J. Arthroplasty
, vol.19
, Issue.8 SUPPL. 3
, pp. 124-130
-
-
Dowson, D.1
Hardaker, C.2
Flett, M.3
Isaac, G.H.4
-
48
-
-
0024378353
-
The wear behavior of capsules and heads of CoCrMo casts in long-term implanted all-metal hip prostheses
-
Senditsch, M., Stretcher, R. M., and Weber, H. The wear behavior of capsules and heads of CoCrMo casts in long-term implanted all-metal hip prostheses. Orthopade, 1989, 18, 377-381.
-
(1989)
Orthopade
, vol.18
, pp. 377-381
-
-
Senditsch, M.1
Stretcher, R.M.2
Weber, H.3
-
49
-
-
0005226043
-
The effect of diametral clearance on wear between head and cup for metal on metal articulations
-
San Francisco, California, USA, 9-13 February
-
Farrar, R. and Schmidt, M. B. The effect of diametral clearance on wear between head and cup for metal on metal articulations. Transactions of the 43rd Annual Meeting of the Orthopaedic Research Society, San Francisco, California, USA, 9-13 February 1997, 71-12.
-
(1997)
Transactions of the 43rd Annual Meeting of the Orthopaedic Research Society
, pp. 12-71
-
-
Farrar, R.1
Schmidt, M.B.2
-
50
-
-
9644257169
-
Large versus small femoral heads in metal-on-metal total hip arthroplasty
-
Cuckler, J. M., Moore, K. D., Lombardi, A. V., McPhereson, E., and Emerson, R. Large versus small femoral heads in metal-on-metal total hip arthroplasty. J. Arthroplasty, 2004, 19(8), Suppl. 3, 41-44.
-
(2004)
J. Arthroplasty
, vol.19
, Issue.8 SUPPL. 3
, pp. 41-44
-
-
Cuckler, J.M.1
Moore, K.D.2
Lombardi, A.V.3
McPhereson, E.4
Emerson, R.5
-
51
-
-
2542607724
-
Changes in the contact area during the bedding-in wear of different sizes of metal on metal hip prostheses
-
Hu, X. Q., Isaac, G. H., and Fisher, J. Changes in the contact area during the bedding-in wear of different sizes of metal on metal hip prostheses. Biorned. Engng Mater., 2004, 14, 145-149.
-
(2004)
Biorned. Engng Mater.
, vol.14
, pp. 145-149
-
-
Hu, X.Q.1
Isaac, G.H.2
Fisher, J.3
-
52
-
-
0042711184
-
The relationship between steady-state wear rate and theoretical film thickness in metal-on-metal total replacement hip joints
-
Elsevier Tribology Series, (Eds D. Dowson, A. A. Lubrecht, G. Dalmaz, and M. Priest), Leeds, 3-6 September 2002, (Elsevier, Amsterdam)
-
Dowson, D. The relationship between steady-state wear rate and theoretical film thickness in metal-on-metal total replacement hip joints. In Proceedings of the 29th Leeds-Lyon Symposium on Tribology, Elsevier Tribology Series, Vol. 41 (Eds D. Dowson, A. A. Lubrecht, G. Dalmaz, and M. Priest), Leeds, 3-6 September 2002, 2003, pp. 273-280 (Elsevier, Amsterdam).
-
(2003)
Proceedings of the 29th Leeds-Lyon Symposium on Tribology
, vol.41
, pp. 273-280
-
-
Dowson, D.1
|