-
1
-
-
0028197478
-
Severe polyethylene wear in total hip arthroplasty: Observations from retrieved AML PLUS hip implants with an ACS polyethylene liner
-
Bono J.V., Sanford L., Toussaint J.T. Severe polyethylene wear in total hip arthroplasty observations from retrieved AML PLUS hip implants with an ACS polyethylene liner. J Arthroplasty. 9:1994;119
-
(1994)
J Arthroplasty
, vol.9
, pp. 119
-
-
Bono, J.V.1
Sanford, L.2
Toussaint, J.T.3
-
2
-
-
5344236310
-
Polyethylene wear data on porous coated acetabular components: Temporal analysis of head penetration to separate true wear from bedding-in
-
Sychterz C.J., Engh C.A. Jr, Yang A.M., Engh C.A. Polyethylene wear data on porous coated acetabular components Temporal analysis of head penetration to separate true wear from bedding-in. Presented at the 66th Annual Meeting of the American Academy of Orthopaedic Surgeons, Anaheim, CA, February 4-8. 1999
-
(1999)
Presented at the 66th Annual Meeting of the American Academy of Orthopaedic Surgeons, Anaheim, CA, February 4-8
-
-
Sychterz, C.J.1
Engh Jr., C.A.2
Yang, A.M.3
Engh, C.A.4
-
3
-
-
0031925519
-
Arthropor 2 acetabular component with screw fixation in primary hip arthroplasty: A 7- to 9-year follow-up study
-
Dearborn J.T., Murray W.R. Arthropor 2 acetabular component with screw fixation in primary hip arthroplasty a 7- to 9-year follow-up study. J Arthroplasty. 13:1998;299
-
(1998)
J Arthroplasty
, vol.13
, pp. 299
-
-
Dearborn, J.T.1
Murray, W.R.2
-
4
-
-
1842297586
-
Long-term results of the Anatomic Medullary Locking prosthesis in total hip arthroplasty
-
Engh C.A. Jr, Culpepper W.J., Engh C.A. Long-term results of the Anatomic Medullary Locking prosthesis in total hip arthroplasty. J Bone and Joint Surg Am. 79:1997;177
-
(1997)
J Bone and Joint Surg Am
, vol.79
, pp. 177
-
-
Engh Jr., C.A.1
Culpepper, W.J.2
Engh, C.A.3
-
5
-
-
0033016232
-
The hemispherical Harris-Galante acetabular cup, inserted without cement: The results of an eight- to eleven-year follow-up of one hundred and sixty-eight hips
-
Petersen M.B., Poulsen I.H., Thomsen J., Solgaard S. The hemispherical Harris-Galante acetabular cup, inserted without cement the results of an eight- to eleven-year follow-up of one hundred and sixty-eight hips. J Bone Joint Surg Am. 81:1999;219
-
(1999)
J Bone Joint Surg Am
, vol.81
, pp. 219
-
-
Petersen, M.B.1
Poulsen, I.H.2
Thomsen, J.3
Solgaard, S.4
-
7
-
-
0017047304
-
Radiological demarcation of cemented sockets in total hip replacement
-
DeLee J.G., Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop. 121:1976;20
-
(1976)
Clin Orthop
, vol.121
, pp. 20
-
-
Delee, J.G.1
Charnley, J.2
-
9
-
-
0033817898
-
Underestimation of pelvic osteolysis: The value of the iliac oblique radiograph
-
Zimlich R.H., Fehring T.K. Underestimation of pelvic osteolysis the value of the iliac oblique radiograph. J Arthroplasty. 15:2000;796
-
(2000)
J Arthroplasty
, vol.15
, pp. 796
-
-
Zimlich, R.H.1
Fehring, T.K.2
-
10
-
-
0041633552
-
Radiographic definition of pelvic osteolysis following total hip arthroplasty
-
Claus A.M., Engh C.A. Jr, Sychterz C.J., et al. Radiographic definition of pelvic osteolysis following total hip arthroplasty. J Bone Joint Surg Am. 85:2003;1519
-
(2003)
J Bone Joint Surg Am
, vol.85
, pp. 1519
-
-
Claus, A.M.1
Engh Jr., C.A.2
Sychterz, C.J.3
-
11
-
-
0035217507
-
Pattern of osteolysis around two different cementless metal-backed cups: Retrospective, radiographic analysis at minimum 10-year follow-up
-
Claus A.M., Sychterz C.J., Hopper R.H. Jr, Engh C.A. Pattern of osteolysis around two different cementless metal-backed cups retrospective, radiographic analysis at minimum 10-year follow-up. J Arthroplasty. 16:(Suppl 1):2001;177
-
(2001)
J Arthroplasty
, vol.16
, Issue.SUPPL. 1
, pp. 177
-
-
Claus, A.M.1
Sychterz, C.J.2
Hopper Jr., R.H.3
Engh, C.A.4
|