메뉴 건너뛰기




Volumn 65, Issue 1, 2006, Pages 72-74

The use of ceramic drills on a zirconium oxide basis in bone preparation

Author keywords

Mixed ceramics; Resistance; Rotating instruments; Zirconium oxide

Indexed keywords

ALUMINUM OXIDE; ZIRCONIUM OXIDE;

EID: 33644976152     PISSN: 00155659     EISSN: 16443284     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (16)

References (8)
  • 1
    • 0022069236 scopus 로고
    • Thermally induced bone necrosis in rabbits: Relation to implant failure in humans
    • Albrektsson T, Eriksson A (1985) Thermally induced bone necrosis in rabbits: relation to implant failure in humans. Clin Orthop, 195: 311-312.
    • (1985) Clin Orthop , vol.195 , pp. 311-312
    • Albrektsson, T.1    Eriksson, A.2
  • 2
    • 0033771089 scopus 로고    scopus 로고
    • Zirconia as a sliding material: Histologic, laboratory and clinical data
    • Cales B (2000) Zirconia as a sliding material: histologic, laboratory and clinical data. Clin Orthop, 379: 94-112.
    • (2000) Clin Orthop , vol.379 , pp. 94-112
    • Cales, B.1
  • 3
    • 0031088297 scopus 로고    scopus 로고
    • Heat generation during implant site preparation: An in vitro study
    • Cordioli G, Majzoub Z (1997) Heat generation during implant site preparation: an in vitro study. Int J Oral Maxillofac Implants, 12: 186-193.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 186-193
    • Cordioli, G.1    Majzoub, Z.2
  • 4
    • 33644985688 scopus 로고    scopus 로고
    • Klinischer Einsatz von Knochenfräsen und Implantatbohrern aus Hochleistungsmischkeramik
    • Gaertner C, B-dsuchter A, Gehrke S, Kleinheinz J (2005) Klinischer Einsatz von Knochenfräsen und Implantatbohrern aus Hochleistungsmischkeramik. Quintessenz, 56:325-332.
    • (2005) Quintessenz , vol.56 , pp. 325-332
    • Gaertner, C.1    Büchter, A.2    Gehrke, S.3    Kleinheinz, J.4
  • 5
    • 0035512351 scopus 로고    scopus 로고
    • Effects of mechanical and thermal fatigue on dental drill performance
    • Harris BH, Kohles SS (2001) Effects of mechanical and thermal fatigue on dental drill performance. Int J Oral Maxillofac Implants, 16: 819-826.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 819-826
    • Harris, B.H.1    Kohles, S.S.2
  • 6
    • 33644980602 scopus 로고    scopus 로고
    • Klinischer Einsatz von Knochenfräsen aus Zirkoniumoxid
    • Hartmann HJ, Steup A (2005) Klinischer Einsatz von Knochenfräsen aus Zirkoniumoxid. ZWR, 114: 532-534.
    • (2005) ZWR , vol.114 , pp. 532-534
    • Hartmann, H.J.1    Steup, A.2
  • 7
    • 0032917811 scopus 로고    scopus 로고
    • Zirconia as a ceramic biomaterial
    • Piconi C, Maccauro G (1999) Zirconia as a ceramic biomaterial. Biomaterials, 20: 1-25.
    • (1999) Biomaterials , vol.20 , pp. 1-25
    • Piconi, C.1    Maccauro, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.