메뉴 건너뛰기




Volumn 26, Issue 1, 2006, Pages 49-57

Retinal thickness in diabetic retinopathy: Comparison of optical coherence tomography, the retinal thickness analyzer, and fundus photography

Author keywords

Diabetic retinopathy; Macular edema; Optical coherence tomography; Retinal thickness analyzer; Stereo fundus photography

Indexed keywords

ADULT; AGED; ANALYZER; ARTICLE; CONTROLLED STUDY; CORRELATION COEFFICIENT; DIABETES MELLITUS; DIABETIC RETINOPATHY; EYE PHOTOGRAPHY; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; OPHTHALMOSCOPY; OPTICAL COHERENCE TOMOGRAPHY; PIGMENT EPITHELIUM; RETINA FOVEA; RETINA MACULA EDEMA; RETINAL THICKNES ANALYZER; SENSITIVITY AND SPECIFICITY; ADOLESCENT; COMPARATIVE STUDY; FEMALE; MALE; METHODOLOGY; MIDDLE AGED; MORPHOMETRICS; PATHOLOGY; PHOTOGRAPHY; RETINA; RETINA MACULA CYSTOID EDEMA; VISUAL SYSTEM EXAMINATION;

EID: 33644869825     PISSN: 0275004X     EISSN: None     Source Type: Journal    
DOI: 10.1097/00006982-200601000-00009     Document Type: Article
Times cited : (46)

References (22)
  • 1
    • 0032945970 scopus 로고    scopus 로고
    • The National Diabetic Retinopathy Laser Treatment Audit. III. Clinical outcomes
    • Bailey CC, Sparrow JM, Grey RHB, Cheng H. The National Diabetic Retinopathy Laser Treatment Audit. III. Clinical outcomes. Eye 1999;13:151-159.
    • (1999) Eye , vol.13 , pp. 151-159
    • Bailey, C.C.1    Sparrow, J.M.2    Grey, R.H.B.3    Cheng, H.4
  • 2
    • 0038016408 scopus 로고    scopus 로고
    • Perspectives on diabetic retinopathy
    • Aiello LM. Perspectives on diabetic retinopathy. Am J Ophthalmol 2003;136:122-135.
    • (2003) Am J Ophthalmol , vol.136 , pp. 122-135
    • Aiello, L.M.1
  • 3
    • 0025892104 scopus 로고
    • Early photocoagulation for diabetic retinopathy - ETDRS report number 9
    • ETDRS Study Group. Early photocoagulation for diabetic retinopathy - ETDRS report number 9. Ophthalmology 1991;98:766-785.
    • (1991) Ophthalmology , vol.98 , pp. 766-785
  • 4
    • 0035108523 scopus 로고    scopus 로고
    • The correlation between retina thickness and axial length as well as age measured by optical coherence tomography
    • Goebel W, Hartmann F, Haigis W. The correlation between retina thickness and axial length as well as age measured by optical coherence tomography. Ophthalmologe 2001;98:157-162.
    • (2001) Ophthalmologe , vol.98 , pp. 157-162
    • Goebel, W.1    Hartmann, F.2    Haigis, W.3
  • 5
    • 0036901279 scopus 로고    scopus 로고
    • Retinal thickness in diabetic retinopathy - A study using optical coherence tomography (OCT)
    • Goebel W, Kretzchmar-Gross T. Retinal thickness in diabetic retinopathy - a study using optical coherence tomography (OCT). Retina 2002;22:759-767.
    • (2002) Retina , vol.22 , pp. 759-767
    • Goebel, W.1    Kretzchmar-Gross, T.2
  • 6
    • 0031952382 scopus 로고    scopus 로고
    • Topography of diabetic macular edema with optical coherence tomography
    • Hee MR, Puliafito CA, Duker JS, et al. Topography of diabetic macular edema with optical coherence tomography. Ophthalmology 1998;105:360-370.
    • (1998) Ophthalmology , vol.105 , pp. 360-370
    • Hee, M.R.1    Puliafito, C.A.2    Duker, J.S.3
  • 7
    • 0031948247 scopus 로고    scopus 로고
    • Reproducibility of retinal thickness measurements in normal eyes using optical coherence tomography
    • Baumann M, Gentile RC, Liebmann JM, Ritch R. Reproducibility of retinal thickness measurements in normal eyes using optical coherence tomography. Ophthalmic Surg Lasers 1998;29:280-285.
    • (1998) Ophthalmic Surg Lasers , vol.29 , pp. 280-285
    • Baumann, M.1    Gentile, R.C.2    Liebmann, J.M.3    Ritch, R.4
  • 8
    • 0036137856 scopus 로고    scopus 로고
    • Diabetic macular edema assessed with optical coherence tomography and stereo fundus photography
    • Strom C, Sander B, Larsen N, et al. Diabetic macular edema assessed with optical coherence tomography and stereo fundus photography. Invest Ophthalmol Vis Sci 2002;43:241-245.
    • (2002) Invest Ophthalmol Vis Sci , vol.43 , pp. 241-245
    • Strom, C.1    Sander, B.2    Larsen, N.3
  • 9
    • 0036237712 scopus 로고    scopus 로고
    • Retinal thickness study with optical coherence tomography in patients with diabetes
    • Sanchez-Tocino H, Alvarez-Vidal A, Maldonado MJ, et al. Retinal thickness study with optical coherence tomography in patients with diabetes. Invest Ophthalmol Vis Sci 2002;43:1588-1594.
    • (2002) Invest Ophthalmol Vis Sci , vol.43 , pp. 1588-1594
    • Sanchez-Tocino, H.1    Alvarez-Vidal, A.2    Maldonado, M.J.3
  • 10
    • 0036156562 scopus 로고    scopus 로고
    • Repeatability and reproducibility of macular thickness measurements with the Humphrey OCT system
    • Muscat S, Parks S, Kemp E, Keating D. Repeatability and reproducibility of macular thickness measurements with the Humphrey OCT system. Invest Ophthalmol Vis Sci 2002;43:490-495.
    • (2002) Invest Ophthalmol Vis Sci , vol.43 , pp. 490-495
    • Muscat, S.1    Parks, S.2    Kemp, E.3    Keating, D.4
  • 11
    • 0036014916 scopus 로고    scopus 로고
    • Retinal thickness in healthy and diabetic subjects measured using optical coherence tomography mapping software
    • Massin P, Erginay A, Haouchine B, et al. Retinal thickness in healthy and diabetic subjects measured using optical coherence tomography mapping software. Eur J Ophthalmol 2002;12:102-108.
    • (2002) Eur J Ophthalmol , vol.12 , pp. 102-108
    • Massin, P.1    Erginay, A.2    Haouchine, B.3
  • 12
    • 0028875360 scopus 로고
    • Quantitative assessment of macular edema with optical coherence tomography
    • Hee MR, Puliafito CA, Wong C, et al. Quantitative assessment of macular edema with optical coherence tomography. Arch Ophthalmol 1995;113:1019-1029.
    • (1995) Arch Ophthalmol , vol.113 , pp. 1019-1029
    • Hee, M.R.1    Puliafito, C.A.2    Wong, C.3
  • 13
    • 0037246369 scopus 로고    scopus 로고
    • A comparison of quantitative mapping and stereoscopic fundus photography grading of retinal thickness in diabetic eyes with macular edema
    • Yang Y, Vitale S, Ding M, et al. A comparison of quantitative mapping and stereoscopic fundus photography grading of retinal thickness in diabetic eyes with macular edema. Ophthalmic Surg Lasers Imaging 2003;34:7-16.
    • (2003) Ophthalmic Surg Lasers Imaging , vol.34 , pp. 7-16
    • Yang, Y.1    Vitale, S.2    Ding, M.3
  • 14
    • 0036905011 scopus 로고    scopus 로고
    • Retinal thickness analysis (RTA) - An objective method to assess and quantify the retinal thickness in healthy controls and in diabetics without diabetic retinopathy
    • Fritsche P, van der Heijde R, Suttorp-Schulten MAS, Polak BC. Retinal thickness analysis (RTA) - an objective method to assess and quantify the retinal thickness in healthy controls and in diabetics without diabetic retinopathy. Retina 2002;22:768-771.
    • (2002) Retina , vol.22 , pp. 768-771
    • Fritsche, P.1    Van Der Heijde, R.2    Suttorp-Schulten, M.A.S.3    Polak, B.C.4
  • 15
    • 0035660566 scopus 로고    scopus 로고
    • Comparison of foveal thickness measured with the retinal thickness analyzer and optical coherence tomography
    • Neubauer AS, Priglinger S, Ullrich S, et al. Comparison of foveal thickness measured with the retinal thickness analyzer and optical coherence tomography. Retina 2001;21:596-601.
    • (2001) Retina , vol.21 , pp. 596-601
    • Neubauer, A.S.1    Priglinger, S.2    Ullrich, S.3
  • 16
    • 0033048216 scopus 로고    scopus 로고
    • Quantitative assessment of macular thickness in normal subjects and patients with diabetic retinopathy by scanning retinal thickness analyser
    • Oshima Y, Emi K, Yamanishi S, Motokura M. Quantitative assessment of macular thickness in normal subjects and patients with diabetic retinopathy by scanning retinal thickness analyser. Br J Ophthalmol 1999;83:54-61.
    • (1999) Br J Ophthalmol , vol.83 , pp. 54-61
    • Oshima, Y.1    Emi, K.2    Yamanishi, S.3    Motokura, M.4
  • 17
    • 0033504882 scopus 로고    scopus 로고
    • Noninvasive mapping of the normal retinal thickness at the posterior pole
    • Asrani S, Zou S, d'Anna S, et al. Noninvasive mapping of the normal retinal thickness at the posterior pole. Ophthalmology 1999;106:269-273.
    • (1999) Ophthalmology , vol.106 , pp. 269-273
    • Asrani, S.1    Zou, S.2    D'Anna, S.3
  • 18
    • 0031689680 scopus 로고    scopus 로고
    • Retinal thickness variation in the diabetic patient measured by the retinal thickness analyser
    • Weinberger D, Axer-Siegel R, Landau D, Yassur Y. Retinal thickness variation in the diabetic patient measured by the retinal thickness analyser. Br J Ophthalmol 1998;82:1003-1006.
    • (1998) Br J Ophthalmol , vol.82 , pp. 1003-1006
    • Weinberger, D.1    Axer-Siegel, R.2    Landau, D.3    Yassur, Y.4
  • 19
    • 0036326137 scopus 로고    scopus 로고
    • Comparison between retinal thickness analyzer and optical coherence tomography for assessment of foveal thickness in eyes with macular disease
    • Polito A, Shah SM, Haller JA, et al. Comparison between retinal thickness analyzer and optical coherence tomography for assessment of foveal thickness in eyes with macular disease. Am J Ophthalmol. 2002;134:240-251.
    • (2002) Am J Ophthalmol , vol.134 , pp. 240-251
    • Polito, A.1    Shah, S.M.2    Haller, J.A.3
  • 20
    • 0036822699 scopus 로고    scopus 로고
    • Retinal thickness in eyes with mild nonproliferative retinopathy in patients with type 2 diabetes mellitus - Comparison of measurements obtained by retinal thickness analysis and optical coherence tomography
    • Pires I, Bernardes RC, Lobo CL, et al. Retinal thickness in eyes with mild nonproliferative retinopathy in patients with type 2 diabetes mellitus - comparison of measurements obtained by retinal thickness analysis and optical coherence tomography. Arch Ophthalmol 2002;120:1301-1306.
    • (2002) Arch Ophthalmol , vol.120 , pp. 1301-1306
    • Pires, I.1    Bernardes, R.C.2    Lobo, C.L.3
  • 21
    • 0035121587 scopus 로고    scopus 로고
    • Retinal thickness measurements with optical coherence tomography and the scanning retinal thickness analyzer
    • Konno S, Akiba J, Yoshida A. Retinal thickness measurements with optical coherence tomography and the scanning retinal thickness analyzer. Retina 2001;21:57-61.
    • (2001) Retina , vol.21 , pp. 57-61
    • Konno, S.1    Akiba, J.2    Yoshida, A.3
  • 22
    • 0034081993 scopus 로고    scopus 로고
    • Optical coherence tomography for retinal thickness measurement in diabetic patients without clinically significant macular edema
    • Schaudig UH, Glaefke C, Scholz F, Richard G. Optical coherence tomography for retinal thickness measurement in diabetic patients without clinically significant macular edema. Ophthalmic Surg Lasers 2000;31:182-186.
    • (2000) Ophthalmic Surg Lasers , vol.31 , pp. 182-186
    • Schaudig, U.H.1    Glaefke, C.2    Scholz, F.3    Richard, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.