메뉴 건너뛰기




Volumn 23, Issue 3, 2006, Pages 345-354

Direct quantitative in vivo comparison of calcified atherosclerotic plaque on vascular MRI and CT by multimodality image registration

Author keywords

Atherosclerosis; CT blooming; Image fusion; Multimodality image registration; Plaque imaging

Indexed keywords

ADULT; AGED; ARTICLE; ATHEROSCLEROTIC PLAQUE; BLOOD VESSEL CALCIFICATION; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER PROGRAM; DIAGNOSTIC PROCEDURE; DIAGNOSTIC VALUE; FEMALE; HUMAN; IMAGE ENHANCEMENT; IN VIVO STUDY; INTERMETHOD COMPARISON; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; THORACIC AORTA; THREE DIMENSIONAL IMAGING;

EID: 33644842007     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.20520     Document Type: Article
Times cited : (18)

References (39)
  • 1
    • 0141885294 scopus 로고    scopus 로고
    • From vulnerable plaque to vulnerable patient: A call for new definitions and risk assessment strategies: Part I
    • Naghavi M, Falk E, Casscells SW, et al. From vulnerable plaque to vulnerable patient: a call for new definitions and risk assessment strategies: Part I. Circulation 2003;108:1664-1672.
    • (2003) Circulation , vol.108 , pp. 1664-1672
    • Naghavi, M.1    Falk, E.2    Casscells, S.W.3
  • 2
    • 0027396961 scopus 로고
    • Transesophageal echocardiographically detected atherosclerotic aortic plaque is a marker for coronary artery disease
    • Fazio G, Redberg R, Winslow T, Schiller N. Transesophageal echocardiographically detected atherosclerotic aortic plaque is a marker for coronary artery disease. J Am Coll Cardiol 1993;21:144-150.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 144-150
    • Fazio, G.1    Redberg, R.2    Winslow, T.3    Schiller, N.4
  • 3
    • 0037674945 scopus 로고    scopus 로고
    • Aortic atherosclerosis detected with electron-beam CT as a predictor of obstructive coronary artery disease
    • Takasu J, Mao S, Budoff M. Aortic atherosclerosis detected with electron-beam CT as a predictor of obstructive coronary artery disease. Acad Radiol 2003;10:631-637.
    • (2003) Acad Radiol , vol.10 , pp. 631-637
    • Takasu, J.1    Mao, S.2    Budoff, M.3
  • 4
    • 3142618935 scopus 로고    scopus 로고
    • In vivo magnetic resonance evaluation of associations between aortic atherosclerosis and both risk factors and coronary artery disease in patients referred for coronary angiography
    • Taniguchi H, Momiyama Y, Fayad Z, et al. In vivo magnetic resonance evaluation of associations between aortic atherosclerosis and both risk factors and coronary artery disease in patients referred for coronary angiography. Am Heart J 2004;148:137-143.
    • (2004) Am Heart J , vol.148 , pp. 137-143
    • Taniguchi, H.1    Momiyama, Y.2    Fayad, Z.3
  • 5
    • 0037044418 scopus 로고    scopus 로고
    • Computed tomography and magnetic resonance imaging for noninvasive coronary angiography and plaque imaging: Current and potential future concepts
    • Fayad ZA, Fuster V, Nikolaou K, Becker C. Computed tomography and magnetic resonance imaging for noninvasive coronary angiography and plaque imaging: current and potential future concepts. Circulation 2002;106:2026-2034.
    • (2002) Circulation , vol.106 , pp. 2026-2034
    • Fayad, Z.A.1    Fuster, V.2    Nikolaou, K.3    Becker, C.4
  • 6
    • 0028807874 scopus 로고
    • Coronary artery calcium area by electron-beam computed tomography and coronary atherosclerotic plaque area. A histopathologic correlative study
    • Rumberger JA, Simons DB, Fitzpatrick LA, Sheedy PF, Schwartz RS. Coronary artery calcium area by electron-beam computed tomography and coronary atherosclerotic plaque area. A histopathologic correlative study. Circulation 1995;92:2157-2162.
    • (1995) Circulation , vol.92 , pp. 2157-2162
    • Rumberger, J.A.1    Simons, D.B.2    Fitzpatrick, L.A.3    Sheedy, P.F.4    Schwartz, R.S.5
  • 8
    • 0042388336 scopus 로고    scopus 로고
    • Automated 3-dimensional registration of stand-alone (18)F-FDG whole-body PET with CT
    • Slomka PJ, Dey D, Przetak C, Aladl UE, Baum RP. Automated 3-dimensional registration of stand-alone (18)F-FDG whole-body PET with CT. J Nucl Med 2003;44:1156-1167.
    • (2003) J Nucl Med , vol.44 , pp. 1156-1167
    • Slomka, P.J.1    Dey, D.2    Przetak, C.3    Aladl, U.E.4    Baum, R.P.5
  • 9
    • 1542378962 scopus 로고    scopus 로고
    • Automated image registration of gated cardiac single-photon emission computed tomography and magnetic resonance imaging
    • Aladl U, Hurwitz G, Dey D, Levin D, Drangova M, Slomka P. Automated image registration of gated cardiac single-photon emission computed tomography and magnetic resonance imaging. J Magn Reson Imaging 2004;19:283-290.
    • (2004) J Magn Reson Imaging , vol.19 , pp. 283-290
    • Aladl, U.1    Hurwitz, G.2    Dey, D.3    Levin, D.4    Drangova, M.5    Slomka, P.6
  • 10
    • 0345686784 scopus 로고    scopus 로고
    • High-speed registration of three- And four-dimensional medical images by using voxel similarity
    • Shekhar R, Zagrodsky V, Castro-Pareja C, Walimbe V, Jagadeesh J. High-speed registration of three- and four-dimensional medical images by using voxel similarity. Radiographics 2003;23:1673-1681.
    • (2003) Radiographics , vol.23 , pp. 1673-1681
    • Shekhar, R.1    Zagrodsky, V.2    Castro-Pareja, C.3    Walimbe, V.4    Jagadeesh, J.5
  • 12
    • 0034910062 scopus 로고    scopus 로고
    • Evaluation of voxel-based registration of 3-D power Doppler ultrasound and 3-D magnetic resonance angiographic images of carotid arteries
    • Slomka P, Mandel J, Downey D, Fenster A. Evaluation of voxel-based registration of 3-D power Doppler ultrasound and 3-D magnetic resonance angiographic images of carotid arteries. Ultrasound Med Biol 2001;27:945-955.
    • (2001) Ultrasound Med Biol , vol.27 , pp. 945-955
    • Slomka, P.1    Mandel, J.2    Downey, D.3    Fenster, A.4
  • 17
    • 0031720879 scopus 로고    scopus 로고
    • Coronary artery disease: Improved reproducibility of calcium scoring with an electron-beam CT volumetric method
    • Callister T, Cooil B, Raya S, Lippolis N, Russo D, Raggi P. Coronary artery disease: improved reproducibility of calcium scoring with an electron-beam CT volumetric method. Radiology 1998;208:807-814.
    • (1998) Radiology , vol.208 , pp. 807-814
    • Callister, T.1    Cooil, B.2    Raya, S.3    Lippolis, N.4    Russo, D.5    Raggi, P.6
  • 18
    • 0037354999 scopus 로고    scopus 로고
    • Noninvasive angiographic evaluation of coronary stents with multi-slice spiral computed tomography
    • Nieman K, Cademartiri F, Raaijmakers R, Pattynama P, de Feyter P. Noninvasive angiographic evaluation of coronary stents with multi-slice spiral computed tomography, Herz 2003;28:136-142.
    • (2003) Herz , vol.28 , pp. 136-142
    • Nieman, K.1    Cademartiri, F.2    Raaijmakers, R.3    Pattynama, P.4    De Feyter, P.5
  • 19
    • 0242585341 scopus 로고    scopus 로고
    • Advances in cardiac imaging with 16-section CT systems
    • Flohr T, Schoepf U, Kuettner A, et al. Advances in cardiac imaging with 16-section CT systems. Acad Radiol 2003;10:386-401.
    • (2003) Acad Radiol , vol.10 , pp. 386-401
    • Flohr, T.1    Schoepf, U.2    Kuettner, A.3
  • 20
    • 0019460905 scopus 로고
    • The exponential edge-gradient effect in x-ray computed tomography
    • Joseph P, Spital R. The exponential edge-gradient effect in x-ray computed tomography. Phys Med Biol 1981;26:473-487.
    • (1981) Phys Med Biol , vol.26 , pp. 473-487
    • Joseph, P.1    Spital, R.2
  • 22
    • 0142178311 scopus 로고    scopus 로고
    • Coronary calcification at electron-beam CT: Effect of section thickness on calcium scoring in vitro and in vivo
    • Vliegenthart R, Song B, Hofman A, Witteman J, Oudkerk M. Coronary calcification at electron-beam CT: effect of section thickness on calcium scoring in vitro and in vivo. Radiology 2003;229:520-525.
    • (2003) Radiology , vol.229 , pp. 520-525
    • Vliegenthart, R.1    Song, B.2    Hofman, A.3    Witteman, J.4    Oudkerk, M.5
  • 23
    • 0035312512 scopus 로고    scopus 로고
    • Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography
    • Schroeder S, Kopp AF, Baumbach A, et al. Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography. J Am Coll Cardiol 2001;37:1430-1435.
    • (2001) J Am Coll Cardiol , vol.37 , pp. 1430-1435
    • Schroeder, S.1    Kopp, A.F.2    Baumbach, A.3
  • 24
    • 0034839070 scopus 로고    scopus 로고
    • Non-invasive characterisation of coronary lesion morphology and composition by multislice CT: First results in comparison with intracoronary ultrasound
    • Kopp AF, Schroeder S, Baumbach A, et al. Non-invasive characterisation of coronary lesion morphology and composition by multislice CT: first results in comparison with intracoronary ultrasound. Eur Radiol 2001;11:1607-1611.
    • (2001) Eur Radiol , vol.11 , pp. 1607-1611
    • Kopp, A.F.1    Schroeder, S.2    Baumbach, A.3
  • 25
    • 0347357884 scopus 로고    scopus 로고
    • Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography: A segment-based comparison with intravascular ultrasound
    • Achenbach S, Moselewski F, Ropers D, et al. Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography: a segment-based comparison with intravascular ultrasound. Circulation 2004;109:14-17.
    • (2004) Circulation , vol.109 , pp. 14-17
    • Achenbach, S.1    Moselewski, F.2    Ropers, D.3
  • 26
    • 0037114795 scopus 로고    scopus 로고
    • Quantitative assessment of atherosclerosis by electron beam tomography
    • Teichholz LE, Petrillo S, Larson AJ, Klig V. Quantitative assessment of atherosclerosis by electron beam tomography. Am J Cardiol 2002;90:1416-1419.
    • (2002) Am J Cardiol , vol.90 , pp. 1416-1419
    • Teichholz, L.E.1    Petrillo, S.2    Larson, A.J.3    Klig, V.4
  • 27
    • 0030744387 scopus 로고    scopus 로고
    • Comparison of electron beam computed tomography with intracoronary ultrasound and coronary angiography for detection of coronary atherosclerosis
    • Baumgart D, Schmermund A, Goerge G, et al. Comparison of electron beam computed tomography with intracoronary ultrasound and coronary angiography for detection of coronary atherosclerosis. J Am Coll Cardiol 1997;30:57-64.
    • (1997) J Am Coll Cardiol , vol.30 , pp. 57-64
    • Baumgart, D.1    Schmermund, A.2    Goerge, G.3
  • 28
    • 0028143172 scopus 로고
    • Quantitative comparisons of image registration techniques based on high-resolution MRI of the brain
    • Strother S, Anderson J, Xu X, Liow J, Bonar D, Rottenberg D. Quantitative comparisons of image registration techniques based on high-resolution MRI of the brain. J Comput Assist Tomogr 1994;18:954-962.
    • (1994) J Comput Assist Tomogr , vol.18 , pp. 954-962
    • Strother, S.1    Anderson, J.2    Xu, X.3    Liow, J.4    Bonar, D.5    Rottenberg, D.6
  • 29
    • 0031727317 scopus 로고    scopus 로고
    • Algorithms for radiological image registration and their clinical application
    • Hawkes D. Algorithms for radiological image registration and their clinical application. J Anat 1998;193:347-361.
    • (1998) J Anat , vol.193 , pp. 347-361
    • Hawkes, D.1
  • 31
    • 0031910991 scopus 로고    scopus 로고
    • Automated image registration: I. General methods and intrasubject, intramodality validation
    • Woods R, Grafton S, Holmes C, Cherry S, Mazziotta J. Automated image registration: I. General methods and intrasubject, intramodality validation. J Comput Assist Tomogr 1998;22:139-152.
    • (1998) J Comput Assist Tomogr , vol.22 , pp. 139-152
    • Woods, R.1    Grafton, S.2    Holmes, C.3    Cherry, S.4    Mazziotta, J.5
  • 32
    • 18844474299 scopus 로고    scopus 로고
    • Comparison and evaluation of retrospective intermodality brain image registration techniques
    • West J, Fitzpatrick J, Wang M, et al. Comparison and evaluation of retrospective intermodality brain image registration techniques. J Comput Assist Tomogr 1997;21:554-566.
    • (1997) J Comput Assist Tomogr , vol.21 , pp. 554-566
    • West, J.1    Fitzpatrick, J.2    Wang, M.3
  • 33
    • 0032587466 scopus 로고    scopus 로고
    • Retrospective intermodality registration techniques for images of the head: Surface-based versus volume-based
    • West J, Fitzpatrick J, Wang M, et al. Retrospective intermodality registration techniques for images of the head: surface-based versus volume-based. IEEE Trans Med Imaging 1999;18:144-150.
    • (1999) IEEE Trans Med Imaging , vol.18 , pp. 144-150
    • West, J.1    Fitzpatrick, J.2    Wang, M.3
  • 34
    • 0344305588 scopus 로고    scopus 로고
    • Quantitative assessment of carotid plaque composition using multicontrast MRI and registered histology
    • Clarke S, Hammond R, Mitchell J, Rutt B. Quantitative assessment of carotid plaque composition using multicontrast MRI and registered histology. Magn Reson Med 2003;50:1199-1208.
    • (2003) Magn Reson Med , vol.50 , pp. 1199-1208
    • Clarke, S.1    Hammond, R.2    Mitchell, J.3    Rutt, B.4
  • 35
    • 2342638270 scopus 로고    scopus 로고
    • Multidetector-row computed tomography and magnetic resonance imaging of atherosclerotic lesions in human ex vivo coronary arteries
    • Nikolaou K, Becker C, Muders M, et al. Multidetector-row computed tomography and magnetic resonance imaging of atherosclerotic lesions in human ex vivo coronary arteries. Atherosclerosis 2004;174:243-252.
    • (2004) Atherosclerosis , vol.174 , pp. 243-252
    • Nikolaou, K.1    Becker, C.2    Muders, M.3
  • 36
    • 11144233333 scopus 로고    scopus 로고
    • Quantitative evaluation of carotid plaque composition by in vivo MRI
    • Saam T, Ferguson M, Yarnykh V, et al. Quantitative evaluation of carotid plaque composition by in vivo MRI. Arterioscler Thromb Vasc Biol 2005;25:234-239.
    • (2005) Arterioscler Thromb Vasc Biol , vol.25 , pp. 234-239
    • Saam, T.1    Ferguson, M.2    Yarnykh, V.3
  • 37
    • 0030088712 scopus 로고    scopus 로고
    • Multi-modal volume registration by maximization of mutual information
    • Wells W, Viola P, Atsumi H, Nakajima S, Kikinis R. Multi-modal volume registration by maximization of mutual information. Med Image Anal 1996;1:35-51.
    • (1996) Med Image Anal , vol.1 , pp. 35-51
    • Wells, W.1    Viola, P.2    Atsumi, H.3    Nakajima, S.4    Kikinis, R.5
  • 38
    • 0034737974 scopus 로고    scopus 로고
    • In vivo magnetic resonance evaluation of atherosclerotic plaques in the human thoracic aorta: A comparison with transesophageal echocardiography
    • Fayad Z, Nahar T, Fallon J, et al. In vivo magnetic resonance evaluation of atherosclerotic plaques in the human thoracic aorta: a comparison with transesophageal echocardiography. Circulation 2000;101:2503-2509.
    • (2000) Circulation , vol.101 , pp. 2503-2509
    • Fayad, Z.1    Nahar, T.2    Fallon, J.3
  • 39
    • 27544474180 scopus 로고    scopus 로고
    • Reproducibility of 3D free-breathing magnetic resonance coronary vessel wall imaging
    • Desai M, Lai S, Barmet C, Weiss R, Stuber M. Reproducibility of 3D free-breathing magnetic resonance coronary vessel wall imaging. Eur Heart J 2005;26:2320-2324.
    • (2005) Eur Heart J , vol.26 , pp. 2320-2324
    • Desai, M.1    Lai, S.2    Barmet, C.3    Weiss, R.4    Stuber, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.