메뉴 건너뛰기




Volumn 17, Issue 4, 2002, Pages 517-525

Immediate Mandibular Rehabilitation with Endosseous Implants: Simultaneous Extraction, Implant Placement, and Loading

Author keywords

Dental implants; Dental prosthesis; Immediate loading; Immediate placement; Mandible

Indexed keywords

ADULT; AGED; ARTICLE; DENTURE; EDENTULOUSNESS; FEMALE; HUMAN; MANDIBLE; METHODOLOGY; MIDDLE AGED; PATIENT CARE; TOOTH EXTRACTION; TOOTH IMPLANTATION; TOOTH PROSTHESIS; TOOTH SOCKET; WEIGHT BEARING;

EID: 0036632724     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (184)

References (32)
  • 1
    • 0033582859 scopus 로고    scopus 로고
    • Total tooth loss among persons aged greater than or equal to 65 Years-Selected States, 1995-1997
    • March 19
    • Total tooth loss among persons aged greater than or equal to 65 Years-Selected States, 1995-1997. Morb Mortal Wkly Rep 1999 March 19;48(10):206-210.
    • (1999) Morb Mortal Wkly Rep , vol.48 , Issue.10 , pp. 206-210
  • 2
    • 0029263609 scopus 로고
    • A 10-year follow-up study of IMZ and TPS implants in the edentulous mandible using bar-retained overdentures
    • Spiekermann H, Jansen VK, Richter EJ. A 10-year follow-up study of IMZ and TPS implants in the edentulous mandible using bar-retained overdentures. Int J Oral Maxillofac Implants 1995;10(2):231-243.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , Issue.2 , pp. 231-243
    • Spiekermann, H.1    Jansen, V.K.2    Richter, E.J.3
  • 3
    • 0030322726 scopus 로고    scopus 로고
    • A prospective 15-year follow-up study of mandibular fixed prostheses supported by osseointegrated implants. Clinical results and marginal bone loss
    • Lindquist LW, Carlsson GE, Jemt T. A prospective 15-year follow-up study of mandibular fixed prostheses supported by osseointegrated implants. Clinical results and marginal bone loss. Clin Oral Implants Res 1996;7(4):329-336.
    • (1996) Clin Oral Implants Res , vol.7 , Issue.4 , pp. 329-336
    • Lindquist, L.W.1    Carlsson, G.E.2    Jemt, T.3
  • 4
    • 0031152016 scopus 로고    scopus 로고
    • Long-term evaluation of non-submerged ITI implants. Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants
    • Buser D, Mericske-Stern R, Bernard JP, et al. Long-term evaluation of non-submerged ITI implants. Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants. Clin Oral Implants Res 1997;8(3):161-172
    • (1997) Clin Oral Implants Res , vol.8 , Issue.3 , pp. 161-172
    • Buser, D.1    Mericske-Stern, R.2    Bernard, J.P.3
  • 5
    • 0032133166 scopus 로고    scopus 로고
    • Five-year prospective follow-up report of the Astra Tech Dental Implant System in the treatment of edentulous mandibles
    • Arvidson K, Bystedt H, Frykholm A, von Konow L, Lothigius E. Five-year prospective follow-up report of the Astra Tech Dental Implant System in the treatment of edentulous mandibles. Clin Oral Implants Res 1998;9(4):225-34.
    • (1998) Clin Oral Implants Res , vol.9 , Issue.4 , pp. 225-234
    • Arvidson, K.1    Bystedt, H.2    Frykholm, A.3    Von Konow, L.4    Lothigius, E.5
  • 6
    • 0033109222 scopus 로고    scopus 로고
    • Five- to six-year results of a prospective clinical trial using the ENDOPORE dental implant and a mandibular overdenture
    • Deporter D, Watson P, Pharoah M, Levy D, Todescan R. Five-to six-year results of a prospective clinical trial using the ENDOPORE dental implant and a mandibular overdenture. Clin Oral Implants Res 1999;10(2):95-102.
    • (1999) Clin Oral Implants Res , vol.10 , Issue.2 , pp. 95-102
    • Deporter, D.1    Watson, P.2    Pharoah, M.3    Levy, D.4    Todescan, R.5
  • 8
    • 0035756677 scopus 로고    scopus 로고
    • Immediate functional loading of immediate implants in edentulous arches: Two-year results
    • Grunder U. Immediate functional loading of immediate implants in edentulous arches: Two-year results. Int J Periodontics Restorative Dent 2001;21:545-551.
    • (2001) Int J Periodontics Restorative Dent , vol.21 , pp. 545-551
    • Grunder, U.1
  • 9
    • 0035748705 scopus 로고    scopus 로고
    • The Hong Kong Bridge Protocol. Immediate loading of mandibular Brånemark fixtures using a fixed provisional prosthesis: Preliminary results
    • Chow J, Hui E, Liu J, et al. The Hong Kong Bridge Protocol. Immediate loading of mandibular Brånemark fixtures using a fixed provisional prosthesis: Preliminary results. Clin Implant Dent Relat Res 2001;3:166-174.
    • (2001) Clin Implant Dent Relat Res , vol.3 , pp. 166-174
    • Chow, J.1    Hui, E.2    Liu, J.3
  • 10
    • 0035407071 scopus 로고    scopus 로고
    • Implant-retained mandibular overdentures with Bånemark System MKII implants: A prospective comparative study between delayed and immediate loading
    • Chiapasco M, Abati S, Romeo E, Vogel G. Implant-retained mandibular overdentures with Bånemark System MKII implants: A prospective comparative study between delayed and immediate loading. Int J Oral Maxillofac Implants 2001;16:537-546.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 537-546
    • Chiapasco, M.1    Abati, S.2    Romeo, E.3    Vogel, G.4
  • 11
    • 0035228432 scopus 로고    scopus 로고
    • Immediate loading of implant-fixed mandibular prostheses: A prospective 18-month follow-up clinical study - Preliminary report
    • Colomina LE. Immediate loading of implant-fixed mandibular prostheses: A prospective 18-month follow-up clinical study - Preliminary report. Implant Dent 2001;10(1) 23-29.
    • (2001) Implant Dent , vol.10 , Issue.1 , pp. 23-29
    • Colomina, L.E.1
  • 12
    • 0033302136 scopus 로고    scopus 로고
    • Brånemark Novum: A new treatment concept for rehabilitation of the edentulous mandible. Preliminary results from a prospective clinical follow-up study
    • Brånemark P-I, Engstrand P, Ohrnell LO, et al. Brånemark Novum: A new treatment concept for rehabilitation of the edentulous mandible. Preliminary results from a prospective clinical follow-up study. Clin Implant Dent Relat Res 1999; 1(1):2-16.
    • (1999) Clin Implant Dent Relat Res , vol.1 , Issue.1 , pp. 2-16
    • Brånemark, P.-I.1    Engstrand, P.2    Ohrnell, L.O.3
  • 13
    • 0034326765 scopus 로고    scopus 로고
    • Immediate loading of Brånemark system implants following placement in edentulous patients: A clinical report
    • Horiuchi K, Uchida H, Yomanoto K, Sugimura M. Immediate loading of Brånemark system implants following placement in edentulous patients: A clinical report. Int J Oral Maxillofac Implants 2000;15:824-830.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 824-830
    • Horiuchi, K.1    Uchida, H.2    Yomanoto, K.3    Sugimura, M.4
  • 14
    • 0034183762 scopus 로고    scopus 로고
    • Immediate loading of implants in partially and fully edentulous jaws: A series of 27 case reports
    • Jaffin RA, Kumar A, Berman CL. Immediate loading of implants in partially and fully edentulous jaws: A series of 27 case reports. J Periodontol 2000;71(5):833-838.
    • (2000) J Periodontol , vol.71 , Issue.5 , pp. 833-838
    • Jaffin, R.A.1    Kumar, A.2    Berman, C.L.3
  • 15
    • 0034186403 scopus 로고    scopus 로고
    • Implant-retained mandibular overdentures with immediate loading: A prospective study of ITI implants
    • Gatti C, Haefliger W, Chiapasco M. Implant-retained mandibular overdentures with immediate loading: A prospective study of ITI implants. Int J Oral Maxillofac Implants 2000;15:383-388.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 383-388
    • Gatti, C.1    Haefliger, W.2    Chiapasco, M.3
  • 17
    • 0033072986 scopus 로고    scopus 로고
    • Immediate functional loading of Brånemark dental implants. An 18-month clinical follow-up study
    • Randow K, Ericsson I, Nilner K, Petersson A, Glantz P-O. Immediate functional loading of Brånemark dental implants. An 18-month clinical follow-up study. Clin Oral Implants Res 1999;10:8-15.
    • (1999) Clin Oral Implants Res , vol.10 , pp. 8-15
    • Randow, K.1    Ericsson, I.2    Nilner, K.3    Petersson, A.4    Glantz, P.-O.5
  • 18
    • 0031061750 scopus 로고    scopus 로고
    • Implant-retained mandibular overdentures with immediate loading. A retrospective multicenter study on 226 consecutive cases
    • Chiapasco M, Gatti C, Rossi E, Haefliger W, Markwalder TH. Implant-retained mandibular overdentures with immediate loading. A retrospective multicenter study on 226 consecutive cases. Clin Oral Implants Res 1997;8:48-57.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 48-57
    • Chiapasco, M.1    Gatti, C.2    Rossi, E.3    Haefliger, W.4    Markwalder, T.H.5
  • 19
    • 0031136510 scopus 로고    scopus 로고
    • Immediate loading of threaded implants at stage 1 surgery in edentulous arches: Ten consecutive case reports with 1- to 5-year data
    • Tarnow DP, Emtiaz S, Classi A. Immediate loading of threaded implants at stage 1 surgery in edentulous arches: Ten consecutive case reports with 1-to 5-year data. Int J Oral Maxillofac Implants 1997;12:319-324.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 319-324
    • Tarnow, D.P.1    Emtiaz, S.2    Classi, A.3
  • 20
    • 0031151465 scopus 로고    scopus 로고
    • Immediate loading of Brånemark implants in edentulous mandibles: A preliminary report
    • Balshi TJ, Wolfinger GJ. Immediate loading of Brånemark implants in edentulous mandibles: A preliminary report. Implant Dent 1997;6:83-88.
    • (1997) Implant Dent , vol.6 , pp. 83-88
    • Balshi, T.J.1    Wolfinger, G.J.2
  • 22
    • 0029348226 scopus 로고
    • Immediate loading of bilaterally splinted titanium root-form implants in fixed prosthodontics - A technique reexamined: Two case reports
    • Salama H, Rose LF, Salama M, Betts NJ. Immediate loading of bilaterally splinted titanium root-form implants in fixed prosthodontics - A technique reexamined: Two case reports. Int J Periodontics Restorative Dent 1995;15:344-361.
    • (1995) Int J Periodontics Restorative Dent , vol.15 , pp. 344-361
    • Salama, H.1    Rose, L.F.2    Salama, M.3    Betts, N.J.4
  • 23
    • 0031183716 scopus 로고    scopus 로고
    • A qualitative and quantitative method for evaluating implant success: A 5-year retrospective analysis of the Brånemark implant
    • Roos J, Sennerby L, Lekholm U, Jemt T, Grondahl K, Albrektsson T. A qualitative and quantitative method for evaluating implant success: A 5-year retrospective analysis of the Brånemark implant. Int J Oral Maxillofac Implants 1997; 12:504-514.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 504-514
    • Roos, J.1    Sennerby, L.2    Lekholm, U.3    Jemt, T.4    Grondahl, K.5    Albrektsson, T.6
  • 24
    • 0035291732 scopus 로고    scopus 로고
    • A multicenter 12-month evaluation of single-tooth implants restored 3 weeks after 1-stage surgery
    • Cooper L, Felton DA, Kugelberg CF, et al. A multicenter 12-month evaluation of single-tooth implants restored 3 weeks after 1-stage surgery. Int J Oral Maxillofac Implants 2001;16:182-192.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 182-192
    • Cooper, L.1    Felton, D.A.2    Kugelberg, C.F.3
  • 25
    • 0032133166 scopus 로고    scopus 로고
    • Five-year prospective follow-up report of the Astra Tech Dental Implant System in the treatment of edentulous mandibles
    • Arvidson K, Bystedt H, Frykholm A, von Konow L, Lothigius E. Five-year prospective follow-up report of the Astra Tech Dental Implant System in the treatment of edentulous mandibles. Clin Oral Implants Res 1998;9:225-234.
    • (1998) Clin Oral Implants Res , vol.9 , pp. 225-234
    • Arvidson, K.1    Bystedt, H.2    Frykholm, A.3    Von Konow, L.4    Lothigius, E.5
  • 26
    • 0017564248 scopus 로고
    • Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period
    • Brånemark PI, Hansson BO, Adell R, et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scan J Plat Reconstr Surg Suppl 1977;16:1-132.
    • (1977) Scan J Plat Reconstr Surg Suppl , vol.16 , pp. 1-132
    • Brånemark, P.I.1    Hansson, B.O.2    Adell, R.3
  • 27
    • 0346344199 scopus 로고
    • Gewebsreaktionauf ein Titan-Hohlzylinder implantat mit Titan-Spritzschichtoberflache
    • Schroeder A, Pohler O, Sutter F. Gewebsreaktionauf ein Titan-Hohlzylinder implantat mit Titan-Spritzschichtoberflache. Schweiz Mschr Zahnheilk 1976;862:16-23.
    • (1976) Schweiz Mschr Zahnheilk , vol.862 , pp. 16-23
    • Schroeder, A.1    Pohler, O.2    Sutter, F.3
  • 28
    • 0035650821 scopus 로고    scopus 로고
    • Early load ing of sandblasted and acid-etched (SLA) implants: A prospective split-mouth comparative study
    • Roccuzzo M, Bunino M, Prioglio F, Bianchi SD. Early load ing of sandblasted and acid-etched (SLA) implants: A prospective split-mouth comparative study. Clin Oral Implants Res 2001;12:572-578.
    • (2001) Clin Oral Implants Res , vol.12 , pp. 572-578
    • Roccuzzo, M.1    Bunino, M.2    Prioglio, F.3    Bianchi, S.D.4
  • 29
    • 0032233311 scopus 로고    scopus 로고
    • A prospective multicenter study evaluating loading of Osseotite implants two months after placement: One-year results
    • Lazzara RJ, Porter SS, Testori T, Galante J, Zetterqvist L. A prospective multicenter study evaluating loading of Osseotite implants two months after placement: One-year results. J Esthet Dent 1998;10:280-289.
    • (1998) J Esthet Dent , vol.10 , pp. 280-289
    • Lazzara, R.J.1    Porter, S.S.2    Testori, T.3    Galante, J.4    Zetterqvist, L.5
  • 30
    • 0034328195 scopus 로고    scopus 로고
    • A role for surface topography in creating and maintaining bone at titanium endosseous implants
    • Cooper LF. A role for surface topography in creating and maintaining bone at titanium endosseous implants. J Prosthet Dent 2000;84:522-534.
    • (2000) J Prosthet Dent , vol.84 , pp. 522-534
    • Cooper, L.F.1
  • 31
    • 0035235831 scopus 로고    scopus 로고
    • Effects of implant design and surface on bone regeneration and implant stability: An experimental study in the dog mandible
    • Rasmusson L, Kahnberg KE, Tan A. Effects of implant design and surface on bone regeneration and implant stability: An experimental study in the dog mandible. Clin Implant Dent Relat Res 2001;3:2-8.
    • (2001) Clin Implant Dent Relat Res , vol.3 , pp. 2-8
    • Rasmusson, L.1    Kahnberg, K.E.2    Tan, A.3
  • 32
    • 0348017064 scopus 로고    scopus 로고
    • A comparative clinical investigation of 2 early loaded ITI dental implants supporting an overdenture in the mandible
    • Roynesdal AK, Amundrud B, Hannaes HR. A comparative clinical investigation of 2 early loaded ITI dental implants supporting an overdenture in the mandible. Int J Oral Maxillofac Implants 2001;16:246-251.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 246-251
    • Roynesdal, A.K.1    Amundrud, B.2    Hannaes, H.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.