메뉴 건너뛰기




Volumn 6007, Issue , 2005, Pages

In-vivo, noninvasive measurement of muscle pH during exercise using near infrared spectroscopy

Author keywords

Clinical sensor; Muscle pH; NIR spectroscopy; PLS Calibration

Indexed keywords

CLINICAL SENSOR; MUSCLE PH; NIR SPECTROSCOPY; PLS CALIBRATION;

EID: 33644676278     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.630646     Document Type: Conference Paper
Times cited : (9)

References (12)
  • 1
    • 0034575576 scopus 로고    scopus 로고
    • In-vivo near infrared spectroscopy
    • P. Wolfe, "In-Vivo Near Infrared Spectroscopy," Annu. Rev. Biomed. Eng. 2, pp 715-754, 2000.
    • (2000) Annu. Rev. Biomed. Eng. , vol.2 , pp. 715-754
    • Wolfe, P.1
  • 2
    • 0025735421 scopus 로고
    • Quantitation of time- and frequency-resolved optical spectra for the determination of tissue oxygenation
    • E.M. Sevic, B. Chance, J. Leigh, S. Nioka, and M. Maris, "Quantitation of time- and frequency-resolved optical spectra for the determination of tissue oxygenation," Anal. Biochem. 195, pp 330-351, 1991.
    • (1991) Anal. Biochem. , vol.195 , pp. 330-351
    • Sevic, E.M.1    Chance, B.2    Leigh, J.3    Nioka, S.4    Maris, M.5
  • 3
    • 0031741774 scopus 로고    scopus 로고
    • Quantitative broadband near-infrared spectroscopy of tissue-simulating phantoms containing erythrocytes
    • E.L. Hull, M.G. Nichols, and T. Foster, "Quantitative broadband near-infrared spectroscopy of tissue-simulating phantoms containing erythrocytes," Phys. Med. Biol. 43, pp 3381-3404, 1998.
    • (1998) Phys. Med. Biol. , vol.43 , pp. 3381-3404
    • Hull, E.L.1    Nichols, M.G.2    Foster, T.3
  • 4
    • 0033874534 scopus 로고    scopus 로고
    • Investigation of noninvasive in vivo hematocrit measurement using NIR reflectance spectroscopy and partial least-squares regression
    • S. Zhang, B.R. Soller, S. Kaur, K. Perras, and T.J. Vander Salm, "Investigation of Noninvasive in Vivo Hematocrit Measurement Using NIR Reflectance Spectroscopy and Partial Least-Squares Regression," Appl. Spectrosc. 54, pp 294-299, 2000.
    • (2000) Appl. Spectrosc. , vol.54 , pp. 294-299
    • Zhang, S.1    Soller, B.R.2    Kaur, S.3    Perras, K.4    Vander Salm, T.J.5
  • 5
    • 0032022570 scopus 로고    scopus 로고
    • Partial least-squares modeling of near-infrared reflectance data for noninvasive in vivo determination of deep-tissue pH
    • S. Zhang, B.R. Soller, and R.H. Micheels, "Partial Least-Squares Modeling of Near-Infrared Reflectance Data for Noninvasive in Vivo Determination of Deep-Tissue pH," Appl.Spectrosc. 52, pp 400-406, 1998.
    • (1998) Appl.Spectrosc. , vol.52 , pp. 400-406
    • Zhang, S.1    Soller, B.R.2    Micheels, R.H.3
  • 6
    • 0042140582 scopus 로고    scopus 로고
    • Noninvasive, near infrared spectroscopic-measured nuscle pH and PO2 indicate tissue perfusion for cardiac surgical patients undergoing cardiopulmonary bypass
    • B.R. Soller, P.O. Idwasi, J. Balaguer, S. Levin, S.A. Simsir, T.J. Vander Salm, H. Collette, and S.O. Heard, "Noninvasive, Near Infrared Spectroscopic-Measured Nuscle pH and PO2 Indicate Tissue Perfusion for Cardiac Surgical Patients Undergoing Cardiopulmonary Bypass," Crit. Care. Med. 31, pp 2324-2331, 2003.
    • (2003) Crit. Care. Med. , vol.31 , pp. 2324-2331
    • Soller, B.R.1    Idwasi, P.O.2    Balaguer, J.3    Levin, S.4    Simsir, S.A.5    Vander Salm, T.J.6    Collette, H.7    Heard, S.O.8
  • 7
    • 0030249031 scopus 로고    scopus 로고
    • Feasibility of noninvasive measurement of tissue pH using near-infrared reflectance spectroscopy
    • B.R. Soller, R.H. Micheels, J. Coen, B. Parikh, L. Chu, and C. Hsi, "Feasibility of Noninvasive Measurement of Tissue pH Using Near-Infrared Reflectance Spectroscopy," J. Clin. Mon. 12, pp 387-396, 1996.
    • (1996) J. Clin. Mon. , vol.12 , pp. 387-396
    • Soller, B.R.1    Micheels, R.H.2    Coen, J.3    Parikh, B.4    Chu, L.5    Hsi, C.6
  • 9
    • 21844461104 scopus 로고    scopus 로고
    • Standardization method for correcting spectral differences across multiple units of a portable near-infrared-based medical monitor
    • O. Soyemi, M. Landry, Y. Yang, B. Soller," Standardization Method for Correcting Spectral Differences Across Multiple Units of a Portable Near-Infrared-Based Medical Monitor," Proc.SPIE. 5702, pp 135-142, 2005.
    • (2005) Proc.SPIE , vol.5702 , pp. 135-142
    • Soyemi, O.1    Landry, M.2    Yang, Y.3    Soller, B.4
  • 11
    • 33644691621 scopus 로고    scopus 로고
    • Multivariate calibration with slowly responding reference measurements
    • in Press
    • M.A. Shear, O.O. Soyemi, M. Landry, B.R, Soller, "Multivariate Calibration With Slowly Responding Reference Measurements,", Proc.SPIE, 6007, (in Press), 2005.
    • (2005) Proc.SPIE , vol.6007
    • Shear, M.A.1    Soyemi, O.O.2    Landry, M.3    Soller, B.R.4
  • 12
    • 0034913366 scopus 로고    scopus 로고
    • Influence of the procedure used to prepare the calibration sample set on the performance of near infrared spectroscopy in quantitative pharmaceutical analysis
    • M. Blanco, J. Coello, H. Iturriaga, S. Maspoch, and N. Pou, "Influence of the Procedure Used to Prepare the Calibration Sample Set On the Performance of Near Infrared Spectroscopy in Quantitative Pharmaceutical Analysis," Analyst, 126, 1129-1134, 2001.
    • (2001) Analyst , vol.126 , pp. 1129-1134
    • Blanco, M.1    Coello, J.2    Iturriaga, H.3    Maspoch, S.4    Pou, N.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.