메뉴 건너뛰기




Volumn 5702, Issue , 2005, Pages 135-142

Standardization method for correcting spectral differences across multiple units of a portable near infrared - Based medical monitor

Author keywords

Blood; Calibration transfer; Instrument standardization; NIR spectroscopy; Phantoms; PLS regression; Tissue

Indexed keywords

CALIBRATION TRANSFER; INSTRUMENT STANDARDIZATION; NEAR INFRARED (NIR) SPECTROSCOPY; PARTIAL LEAST SQUARES (PLS) REGRESSION; PHANTOMS;

EID: 21844461104     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.585962     Document Type: Conference Paper
Times cited : (7)

References (19)
  • 1
    • 0025735421 scopus 로고
    • Quantitation of time- and frequency-resolved optical spectra for the determination of tissue oxygenation
    • E.M. Sevic, B. Chance, J. Leigh, S. Nioka, and M. Maris, "Quantitation of time- and frequency-resolved optical spectra for the determination of tissue oxygenation," Anal. Biochem. 195, pp 330-351, 1991.
    • (1991) Anal. Biochem. , vol.195 , pp. 330-351
    • Sevic, E.M.1    Chance, B.2    Leigh, J.3    Nioka, S.4    Maris, M.5
  • 2
    • 0031741774 scopus 로고    scopus 로고
    • Quantitative broadband near-infrared spectroscopy of tissue-simulating phantoms containing erythrocytes
    • E.L. Hull, M.G. Nichols, and T. Foster, "Quantitative broadband near-infrared spectroscopy of tissue-simulating phantoms containing erythrocytes," Phys. Med. Biol. 43, pp 3381-3404, 1998.
    • (1998) Phys. Med. Biol. , vol.43 , pp. 3381-3404
    • Hull, E.L.1    Nichols, M.G.2    Foster, T.3
  • 3
    • 0027530250 scopus 로고
    • SIMPLS: An alternative approach to partial least squares regression
    • S. de Jong, "SIMPLS: an alternative approach to partial least squares regression," Chemom.Intell.Lab.Sys. 18, pp 251-269, 1993.
    • (1993) Chemom.Intell.Lab.Sys. , vol.18 , pp. 251-269
    • De Jong, S.1
  • 5
    • 0033874534 scopus 로고    scopus 로고
    • Investigation of noninvasive in vivo blood hematocrit measurement using NIR reflectance spectroscopy and partial least squares regression
    • S. Zhang, B.R. Soller, S. Kaur, K. Perras, and T.J. Vander Salm, "Investigation of noninvasive in vivo blood hematocrit measurement using NIR reflectance spectroscopy and partial least squares regression," Appl. Spectrosc. 54, pp 294-299, 2000.
    • (2000) Appl. Spectrosc. , vol.54 , pp. 294-299
    • Zhang, S.1    Soller, B.R.2    Kaur, S.3    Perras, K.4    Salm, T.J.V.5
  • 7
    • 0026005327 scopus 로고
    • Absorption spectra of human fetal and adult oxyhemoglobin, deoxyhemoglobin, carboxyhemoglobin, and methemoglobin
    • W.G. Zijlstra, A. Buursma, and W.P. Meeuwsen - van der Roest, "Absorption spectra of human fetal and adult oxyhemoglobin, deoxyhemoglobin, carboxyhemoglobin, and methemoglobin," Clin. Chem. 37, pp 1633-1638, 1991.
    • (1991) Clin. Chem. , vol.37 , pp. 1633-1638
    • Zijlstra, W.G.1    Buursma, A.2    Van Der Roest, W.P.M.3
  • 8
    • 0002474463 scopus 로고
    • Spectrophotometric studies II: Preparations from washed blood cells; nitric oxide hemoglobin and sulfhemoglobin
    • D.L. Drabkin and J.H. Austin, "Spectrophotometric studies II: Preparations from washed blood cells; nitric oxide hemoglobin and sulfhemoglobin," J. Biol. Chem. 112, pp 51-65, 1935.
    • (1935) J. Biol. Chem. , vol.112 , pp. 51-65
    • Drabkin, D.L.1    Austin, J.H.2
  • 9
    • 84860960174 scopus 로고    scopus 로고
    • accessed May 28, 2004
    • Sigma-Aldrich Corp. web page. http://www.sigmaaldrich/datasheet/d5941dat. pdf (accessed May 28, 2004).
    • Sigma-Aldrich Corp. Web Page
  • 10
    • 0032969160 scopus 로고    scopus 로고
    • The determination of in vivo human tissue properties and absolute chromphore concentrations using spatially resolved steady-state diffuse reflectance spectroscopy
    • R.M.P. Doornbos, R. Lang, M.C. Aalders, F.W. Cross, and H.J.C. Sterenberg, "The determination of in vivo human tissue properties and absolute chromphore concentrations using spatially resolved steady-state diffuse reflectance spectroscopy," Phys. Med. Biol. 44, pp 967-981, 1999.
    • (1999) Phys. Med. Biol. , vol.44 , pp. 967-981
    • Doornbos, R.M.P.1    Lang, R.2    Aalders, M.C.3    Cross, F.W.4    Sterenberg, H.J.C.5
  • 11
    • 2542500560 scopus 로고    scopus 로고
    • Effects of fiber-optic probe design and probe-to-target distance on diffuse reflectance measurements of turbid media: An experimental and computational study at 337nm
    • T. Papaioannou, N.W. Preyer, Q. Fang, A. Brightwell, M. Carnohan, G. Cottone, R. Ross, L.R. Jones, and L. Marcu, "Effects of fiber-optic probe design and probe-to-target distance on diffuse reflectance measurements of turbid media: an experimental and computational study at 337nm," Appl. Opt. 43, pp 2846-2860, 2004.
    • (2004) Appl. Opt. , vol.43 , pp. 2846-2860
    • Papaioannou, T.1    Preyer, N.W.2    Fang, Q.3    Brightwell, A.4    Carnohan, M.5    Cottone, G.6    Ross, R.7    Jones, L.R.8    Marcu, L.9
  • 12
    • 0024701578 scopus 로고
    • Standard normal variate transformation and detrending of near-infrared diffuse reflectance spectra
    • R.J. Barnes, M.S. Dhanoa, and S.J. Lister, "Standard normal variate transformation and detrending of near-infrared diffuse reflectance spectra," Appl. Spectrosc. 43, pp 772-777, 1989.
    • (1989) Appl. Spectrosc. , vol.43 , pp. 772-777
    • Barnes, R.J.1    Dhanoa, M.S.2    Lister, S.J.3
  • 13
    • 0000920105 scopus 로고
    • Multivariate instrument standardization
    • Y. Wang, D.J. Veltkamp, and B.R. Kowalski, "Multivariate instrument standardization," Anal. Chem. 63, pp 2750-2756, 1991.
    • (1991) Anal. Chem. , vol.63 , pp. 2750-2756
    • Wang, Y.1    Veltkamp, D.J.2    Kowalski, B.R.3
  • 14
    • 0000808960 scopus 로고
    • Calibration transfer and measurement stability of near-infrared spectrometers
    • Y. Wang and B.R. Kowalski, "Calibration transfer and measurement stability of near-infrared spectrometers," Appl. Spectrosc. 46, 764-771, 1992.
    • (1992) Appl. Spectrosc. , vol.46 , pp. 764-771
    • Wang, Y.1    Kowalski, B.R.2
  • 15
    • 0141812475 scopus 로고    scopus 로고
    • An evaluation of orthogonal signal correction applied to calibration transfer of near infrared spectra
    • J. Sjoblom, O. Svensson, M. Josefson, H. Kullberg, and S. Wold, "An evaluation of orthogonal signal correction applied to calibration transfer of near infrared spectra," Chemom. Intell. Lab. Sys. 44, pp 229-244, 1998.
    • (1998) Chemom. Intell. Lab. Sys. , vol.44 , pp. 229-244
    • Sjoblom, J.1    Svensson, O.2    Josefson, M.3    Kullberg, H.4    Wold, S.5
  • 17
    • 0343266773 scopus 로고
    • Multivariate Calibration Transfer: The importance of standardizing instrumentation
    • J. Workman and J. Coates "Multivariate Calibration Transfer: The importance of standardizing instrumentation," Spectroscopy, 8, pp 36-42, 1993
    • (1993) Spectroscopy , vol.8 , pp. 36-42
    • Workman, J.1    Coates, J.2
  • 18
    • 84860960289 scopus 로고    scopus 로고
    • "Instrument standardization for a spectroscopic device," U.S. Pat. Appl. Publ. No. 20030160954
    • T. Wang, B.H, Radzuik, and D.H. Tracy, "Instrument standardization for a spectroscopic device," U.S. Pat. Appl. Publ. No. 20030160954, 2003.
    • (2003)
    • Wang, T.1    Radzuik, B.H.2    Tracy, D.H.3
  • 19
    • 0036913186 scopus 로고    scopus 로고
    • The transfer between instruments of a reflectance near-infrared assay for paracetamol in intact tablets
    • R.M. Smith, R.D. Jee, A.C. Moffat, "The transfer between instruments of a reflectance near-infrared assay for paracetamol in intact tablets," Analyst, 127, pp 1682-1692, 2002.
    • (2002) Analyst , vol.127 , pp. 1682-1692
    • Smith, R.M.1    Jee, R.D.2    Moffat, A.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.