메뉴 건너뛰기




Volumn 34, Issue 1, 2006, Pages 25-32

Oxygen carriers: A selected review

Author keywords

Hemoglobin; Hemoglobin based oxygen carriers; Oxygen carriers; Perfluorocarbon

Indexed keywords

FLUOROCARBON; HEMOGLOBIN; OXYGEN; PERFLUORODECALIN; PERFLUOROOCTYL BROMIDE; PERFLUOROPENTANE; POLYMERIZED HEMOGLOBIN; RAFFINOSE; RECOMBINANT HEMOGLOBIN;

EID: 32344451588     PISSN: 14730502     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.transci.2005.09.005     Document Type: Conference Paper
Times cited : (27)

References (47)
  • 1
    • 0037431753 scopus 로고    scopus 로고
    • Transfusion medicine: Looking to the future
    • L.T. Goodnough, A. Shander, and M.E. Brecher Transfusion medicine: looking to the future Lancet 361 2003 161 169
    • (2003) Lancet , vol.361 , pp. 161-169
    • Goodnough, L.T.1    Shander, A.2    Brecher, M.E.3
  • 3
    • 0014624190 scopus 로고
    • Structure and function of hemoglobin
    • M.F. Perutz Structure and function of hemoglobin Harvey Lect 63 1969 213 261
    • (1969) Harvey Lect , vol.63 , pp. 213-261
    • Perutz, M.F.1
  • 4
    • 0001166627 scopus 로고
    • Clinical experience with hemoglobin-saline solutions
    • W. Amberson, J. Jennings, and C. Martin Rhode Clinical experience with hemoglobin-saline solutions J Appl Physiol 1 1949 469 489
    • (1949) J Appl Physiol , vol.1 , pp. 469-489
    • Amberson, W.1    Jennings, J.2    Martin Rhode, C.3
  • 5
    • 0036789874 scopus 로고    scopus 로고
    • The life-sustaining capacity of human polymerized hemoglobin when red cells might be unavailable
    • S.A. Gould, E.E. Moore, D.B. Hoyt, P.M. Ness, E.J. Norris, and J.L. Carson The life-sustaining capacity of human polymerized hemoglobin when red cells might be unavailable J Am Coll Surg 195 2002 445 452 [discussion 452-445]
    • (2002) J Am Coll Surg , vol.195 , pp. 445-452
    • Gould, S.A.1    Moore, E.E.2    Hoyt, D.B.3    Ness, P.M.4    Norris, E.J.5    Carson, J.L.6
  • 6
    • 0036209470 scopus 로고    scopus 로고
    • The use of bovine hemoglobin glutamer-250 (Hemopure) in surgical patients: Results of a multicenter, randomized, single-blinded trial
    • J. Sprung, J.D. Kindscher, J.A. Wahr, J.H. Levy, T.G. Monk, and M.W. Moritz The use of bovine hemoglobin glutamer-250 (Hemopure) in surgical patients: results of a multicenter, randomized, single-blinded trial Anesth Analg 94 2002 799 808 [table of contents]
    • (2002) Anesth Analg , vol.94 , pp. 799-808
    • Sprung, J.1    Kindscher, J.D.2    Wahr, J.A.3    Levy, J.H.4    Monk, T.G.5    Moritz, M.W.6
  • 7
    • 0031737577 scopus 로고    scopus 로고
    • Functional comparison of specifically cross-linked hemoglobins biased toward the R and T states
    • M.B. Johnson, J.G. Adamson, and A.G. Mauk Functional comparison of specifically cross-linked hemoglobins biased toward the R and T states Biophys J 75 1998 3078 3084
    • (1998) Biophys J , vol.75 , pp. 3078-3084
    • Johnson, M.B.1    Adamson, J.G.2    Mauk, A.G.3
  • 8
    • 0032984832 scopus 로고    scopus 로고
    • O-raffinose cross-linking markedly reduces systemic and renal vasoconstrictor effects of unmodified human hemoglobin
    • W. Lieberthal, R. Fuhro, J.E. Freedman, G. Toolan, J. Loscalzo, and C.R. Valeri O-raffinose cross-linking markedly reduces systemic and renal vasoconstrictor effects of unmodified human hemoglobin J Pharmacol Exp Ther 288 1999 1278 1287
    • (1999) J Pharmacol Exp Ther , vol.288 , pp. 1278-1287
    • Lieberthal, W.1    Fuhro, R.2    Freedman, J.E.3    Toolan, G.4    Loscalzo, J.5    Valeri, C.R.6
  • 9
    • 0035226529 scopus 로고    scopus 로고
    • O-raffinose-polymerised haemoglobin. a biochemical and pharmacological profile of an oxygen carrier
    • R. Scatena, and B. Giardina O-raffinose-polymerised haemoglobin. A biochemical and pharmacological profile of an oxygen carrier Expert Opin Biol Ther 1 2001 121 127
    • (2001) Expert Opin Biol Ther , vol.1 , pp. 121-127
    • Scatena, R.1    Giardina, B.2
  • 10
    • 0035465476 scopus 로고    scopus 로고
    • Oxygen carriers ("blood substitutes")-raison d'etre, chemistry, and some physiology
    • J.G. Riess Oxygen carriers ("blood substitutes")-raison d'etre, chemistry, and some physiology Chem Rev 101 2001 2797 2920
    • (2001) Chem Rev , vol.101 , pp. 2797-2920
    • Riess, J.G.1
  • 11
    • 10644243494 scopus 로고    scopus 로고
    • Cross-linking with O-raffinose lowers oxygen affinity and stabilizes haemoglobin in a non-cooperative T-state conformation
    • Y. Jia, S. Ramasamy, F. Wood, A.I. Alayash, and J.M. Rifkind Cross-linking with O-raffinose lowers oxygen affinity and stabilizes haemoglobin in a non-cooperative T-state conformation Biochem J 384 2004 367 375
    • (2004) Biochem J , vol.384 , pp. 367-375
    • Jia, Y.1    Ramasamy, S.2    Wood, F.3    Alayash, A.I.4    Rifkind, J.M.5
  • 13
    • 46149128444 scopus 로고
    • Prolonged vascular retention of a hemoglobin solution modified by cross-linking with 2-nor-2-formylpyridoxal 5′-phosphate
    • W.K. Bleeker, J. van der Plas, J. Agterberg, G. Rigter, and J.C. Bakker Prolonged vascular retention of a hemoglobin solution modified by cross-linking with 2-nor-2-formylpyridoxal 5′-phosphate J Lab Clin Med 108 1986 448 455
    • (1986) J Lab Clin Med , vol.108 , pp. 448-455
    • Bleeker, W.K.1    Van Der Plas, J.2    Agterberg, J.3    Rigter, G.4    Bakker, J.C.5
  • 15
    • 0032714203 scopus 로고    scopus 로고
    • Diaspirin cross-linked hemoglobin effectively restores pancreatic microcirculatory failure in hemorrhagic shock
    • E. von Dobschuetz, T. Hoffmann, and K. Messmer Diaspirin cross-linked hemoglobin effectively restores pancreatic microcirculatory failure in hemorrhagic shock Anesthesiology 91 1999 1754 1762
    • (1999) Anesthesiology , vol.91 , pp. 1754-1762
    • Von Dobschuetz, E.1    Hoffmann, T.2    Messmer, K.3
  • 16
    • 4544243218 scopus 로고    scopus 로고
    • A prospective trial of diaspirin cross-linked hemoglobin solution in patients after elective repair of abdominal aortic aneurysm
    • E.L. Bloomfield, M.Y. Rady, and S. Esfandiari A prospective trial of diaspirin cross-linked hemoglobin solution in patients after elective repair of abdominal aortic aneurysm Mil Med 169 2004 546 550
    • (2004) Mil Med , vol.169 , pp. 546-550
    • Bloomfield, E.L.1    Rady, M.Y.2    Esfandiari, S.3
  • 17
    • 0036092276 scopus 로고    scopus 로고
    • Post hoc mortality analysis of the efficacy trial of diaspirin cross-linked hemoglobin in the treatment of severe traumatic hemorrhagic shock
    • E.P. Sloan, M. Koenigsberg, P.H. Brunett, R.P. Bynoe, J.A. Morris, and G. Tinkoff Post hoc mortality analysis of the efficacy trial of diaspirin cross-linked hemoglobin in the treatment of severe traumatic hemorrhagic shock J Trauma 52 2002 887 895
    • (2002) J Trauma , vol.52 , pp. 887-895
    • Sloan, E.P.1    Koenigsberg, M.2    Brunett, P.H.3    Bynoe, R.P.4    Morris, J.A.5    Tinkoff, G.6
  • 18
    • 0019490784 scopus 로고
    • Preparation and oxygen binding properties of soluble covalent hemoglobin-dextran conjugates
    • F. Bonneaux, P. Labrude, and E. Dellacherie Preparation and oxygen binding properties of soluble covalent hemoglobin-dextran conjugates Experientia 37 1981 884 886
    • (1981) Experientia , vol.37 , pp. 884-886
    • Bonneaux, F.1    Labrude, P.2    Dellacherie, E.3
  • 19
    • 0029738132 scopus 로고    scopus 로고
    • Hemoglobin-dialdehyde dextran conjugates: Improvement of their oxygen-binding properties with anionic groups
    • F. Bonneaux, E. Dellacherie, P. Labrude, and C. Vigneron Hemoglobin-dialdehyde dextran conjugates: improvement of their oxygen-binding properties with anionic groups J Protein Chem 15 1996 461 465
    • (1996) J Protein Chem , vol.15 , pp. 461-465
    • Bonneaux, F.1    Dellacherie, E.2    Labrude, P.3    Vigneron, C.4
  • 20
    • 0026671057 scopus 로고
    • Relationship between chemical properties and biological properties of pyridoxalated hemoglobin-polyoxyethylene
    • Y. Iwashita Relationship between chemical properties and biological properties of pyridoxalated hemoglobin-polyoxyethylene Biomater Artif Cells Immobil Biotechnol 20 1992 299 307
    • (1992) Biomater Artif Cells Immobil Biotechnol , vol.20 , pp. 299-307
    • Iwashita, Y.1
  • 22
    • 4344592222 scopus 로고    scopus 로고
    • MP4, a new nonvasoactive polyethylene glycol-hemoglobin conjugate
    • R.M. Winslow MP4, a new nonvasoactive polyethylene glycol-hemoglobin conjugate Artif Organs 28 2004 800 806
    • (2004) Artif Organs , vol.28 , pp. 800-806
    • Winslow, R.M.1
  • 23
    • 0037939683 scopus 로고    scopus 로고
    • Resuscitation with a novel hemoglobin-based oxygen carrier in a Swine model of uncontrolled perioperative hemorrhage
    • A.K. Malhotra, M.E. Kelly, P.R. Miller, J.C. Hartman, T.C. Fabian, and K.G. Proctor Resuscitation with a novel hemoglobin-based oxygen carrier in a Swine model of uncontrolled perioperative hemorrhage J Trauma 54 2003 915 924
    • (2003) J Trauma , vol.54 , pp. 915-924
    • Malhotra, A.K.1    Kelly, M.E.2    Miller, P.R.3    Hartman, J.C.4    Fabian, T.C.5    Proctor, K.G.6
  • 24
    • 0027377056 scopus 로고
    • Oxygen equilibrium studies of cross-linked iron-cobalt hybrid hemoglobins. Models for partially ligated intermediates of cobalt hemoglobin
    • A. Tsuneshige, Y.X. Zhou, and T. Yonetani Oxygen equilibrium studies of cross-linked iron-cobalt hybrid hemoglobins. Models for partially ligated intermediates of cobalt hemoglobin J Biol Chem 268 1993 23031 23040
    • (1993) J Biol Chem , vol.268 , pp. 23031-23040
    • Tsuneshige, A.1    Zhou, Y.X.2    Yonetani, T.3
  • 25
    • 0027290428 scopus 로고
    • Oxygen equilibrium properties of asymmetric nickel(II)-iron(II) hybrid hemoglobin
    • N. Shibayama, K. Imai, H. Morimoto, and S. Saigo Oxygen equilibrium properties of asymmetric nickel(II)-iron(II) hybrid hemoglobin Biochemistry 32 1993 8792 8798
    • (1993) Biochemistry , vol.32 , pp. 8792-8798
    • Shibayama, N.1    Imai, K.2    Morimoto, H.3    Saigo, S.4
  • 26
    • 0038503269 scopus 로고    scopus 로고
    • Functional and spectroscopic characterization of half-liganded iron-zinc hybrid hemoglobin: Evidence for conformational plasticity within the T state
    • U. Samuni, L. Juszczak, D. Dantsker, I. Khan, A.J. Friedman, and J. Perez-Gonzalez-de-Apodaca Functional and spectroscopic characterization of half-liganded iron-zinc hybrid hemoglobin: evidence for conformational plasticity within the T state Biochemistry 42 2003 8272 8288
    • (2003) Biochemistry , vol.42 , pp. 8272-8288
    • Samuni, U.1    Juszczak, L.2    Dantsker, D.3    Khan, I.4    Friedman, A.J.5    Perez-Gonzalez-De-Apodaca, J.6
  • 27
    • 0020581256 scopus 로고
    • Encapsulation of hemoglobin in phospholipid vesicles
    • B.P. Gaber, P. Yager, J.P. Sheridan, and E.L. Chang Encapsulation of hemoglobin in phospholipid vesicles FEBS Lett 153 1983 285 288
    • (1983) FEBS Lett , vol.153 , pp. 285-288
    • Gaber, B.P.1    Yager, P.2    Sheridan, J.P.3    Chang, E.L.4
  • 28
    • 0347413685 scopus 로고    scopus 로고
    • Determination of size distribution and encapsulation efficiency of liposome-encapsulated hemoglobin blood substitutes using asymmetric flow field-flow fractionation coupled with multi-angle static light scattering
    • D.R. Arifin, and A.F. Palmer Determination of size distribution and encapsulation efficiency of liposome-encapsulated hemoglobin blood substitutes using asymmetric flow field-flow fractionation coupled with multi-angle static light scattering Biotechnol Prog 19 2003 1798 1811
    • (2003) Biotechnol Prog , vol.19 , pp. 1798-1811
    • Arifin, D.R.1    Palmer, A.F.2
  • 29
    • 0021873081 scopus 로고
    • Encapsulation of hemoglobin in phospholipid liposomes: Characterization and stability
    • J. Szebeni, E.E. Di Iorio, H. Hauser, and K.H. Winterhalter Encapsulation of hemoglobin in phospholipid liposomes: characterization and stability Biochemistry 24 1985 2827 2832
    • (1985) Biochemistry , vol.24 , pp. 2827-2832
    • Szebeni, J.1    Di Iorio, E.E.2    Hauser, H.3    Winterhalter, K.H.4
  • 31
    • 10044298332 scopus 로고    scopus 로고
    • Physiological capacity of the reticuloendothelial system for the degradation of hemoglobin vesicles (artificial oxygen carriers) after massive intravenous doses by daily repeated infusions for 14 days
    • H. Sakai, Y. Masada, H. Horinouchi, E. Ikeda, K. Sou, and S. Takeoka Physiological capacity of the reticuloendothelial system for the degradation of hemoglobin vesicles (artificial oxygen carriers) after massive intravenous doses by daily repeated infusions for 14 days J Pharmacol Exp Ther 311 2004 874 884
    • (2004) J Pharmacol Exp Ther , vol.311 , pp. 874-884
    • Sakai, H.1    Masada, Y.2    Horinouchi, H.3    Ikeda, E.4    Sou, K.5    Takeoka, S.6
  • 33
    • 0028224261 scopus 로고
    • Cardiovascular and coronary physiology of acute isovolemic hemodilution: A review of nonoxygen-carrying and oxygen-carrying solutions
    • D.R. Spahn, B.J. Leone, J.G. Reves, and T. Pasch Cardiovascular and coronary physiology of acute isovolemic hemodilution: a review of nonoxygen-carrying and oxygen-carrying solutions Anesth Analg 78 1994 1000 1021
    • (1994) Anesth Analg , vol.78 , pp. 1000-1021
    • Spahn, D.R.1    Leone, B.J.2    Reves, J.G.3    Pasch, T.4
  • 34
    • 0025944867 scopus 로고
    • Fluorocarbon-based in vivo oxygen transport and delivery systems
    • J.G. Riess Fluorocarbon-based in vivo oxygen transport and delivery systems Vox Sang 61 1991 225 239
    • (1991) Vox Sang , vol.61 , pp. 225-239
    • Riess, J.G.1
  • 35
    • 0017244555 scopus 로고
    • Alterations of liver and spleen following intravenous infusion of fluorocarbon emulsions
    • W.I. Rosenblum, M.G. Hadfield, A.J. Martinez, and P. Schatzki Alterations of liver and spleen following intravenous infusion of fluorocarbon emulsions Arch Pathol Lab Med 100 1976 213 217
    • (1976) Arch Pathol Lab Med , vol.100 , pp. 213-217
    • Rosenblum, W.I.1    Hadfield, M.G.2    Martinez, A.J.3    Schatzki, P.4
  • 36
    • 0028589923 scopus 로고
    • Current status of injectable oxygen carriers
    • T.F. Zuck, and J.G. Riess Current status of injectable oxygen carriers Crit Rev Clin Lab Sci 31 1994 295 324
    • (1994) Crit Rev Clin Lab Sci , vol.31 , pp. 295-324
    • Zuck, T.F.1    Riess, J.G.2
  • 37
    • 0029032058 scopus 로고
    • Perfluorocarbons in the twenty-first century: Clinical applications as transfusion alternatives
    • R.K. Spence Perfluorocarbons in the twenty-first century: clinical applications as transfusion alternatives Artif Cells Blood Substit Immobil Biotechnol 23 1995 367 380
    • (1995) Artif Cells Blood Substit Immobil Biotechnol , vol.23 , pp. 367-380
    • Spence, R.K.1
  • 38
    • 0029805358 scopus 로고    scopus 로고
    • Resuscitation and the limited utility of the present generation of blood substitutes
    • J.R. Hess, and R.F. Reiss Resuscitation and the limited utility of the present generation of blood substitutes Transfus Med Rev 10 1996 276 285
    • (1996) Transfus Med Rev , vol.10 , pp. 276-285
    • Hess, J.R.1    Reiss, R.F.2
  • 39
    • 0028330953 scopus 로고
    • Oxygen delivery augmentation by low-dose perfluorochemical emulsion during profound normovolemic hemodilution
    • P.E. Keipert, N.S. Faithfull, J.D. Bradley, D.Y. Hazard, J. Hogan, and M.S. Levisetti Oxygen delivery augmentation by low-dose perfluorochemical emulsion during profound normovolemic hemodilution Adv Exp Med Biol 345 1994 197 204
    • (1994) Adv Exp Med Biol , vol.345 , pp. 197-204
    • Keipert, P.E.1    Faithfull, N.S.2    Bradley, J.D.3    Hazard, D.Y.4    Hogan, J.5    Levisetti, M.S.6
  • 42
    • 0027033852 scopus 로고
    • [Fluorocarbon emulsions as injectable oxygen carriers. Recent progress and perspectives
    • J.G. Riess [Fluorocarbon emulsions as injectable oxygen carriers. Recent progress and perspectives Rev Fr Transfus Hemobiol 35 1992 391 406
    • (1992) Rev Fr Transfus Hemobiol , vol.35 , pp. 391-406
    • Riess, J.G.1
  • 43
    • 0033799895 scopus 로고    scopus 로고
    • Randomized safety studies of intravenous perflubron emulsion. I. Effects on coagulation function in healthy volunteers
    • P.T. Leese, R.J. Noveck, J.S. Shorr, C.M. Woods, K.E. Flaim, and P.E. Keipert Randomized safety studies of intravenous perflubron emulsion. I. Effects on coagulation function in healthy volunteers Anesth Analg 91 2000 804 811
    • (2000) Anesth Analg , vol.91 , pp. 804-811
    • Leese, P.T.1    Noveck, R.J.2    Shorr, J.S.3    Woods, C.M.4    Flaim, K.E.5    Keipert, P.E.6
  • 44
    • 0036897047 scopus 로고    scopus 로고
    • Use of perflubron emulsion to decrease allogeneic blood transfusion in high-blood-loss non-cardiac surgery: Results of a European phase 3 study
    • D.R. Spahn, K.F. Waschke, T. Standl, J. Motsch, L. Van Huynegem, and M. Welte Use of perflubron emulsion to decrease allogeneic blood transfusion in high-blood-loss non-cardiac surgery: results of a European phase 3 study Anesthesiology 97 2002 1338 1349
    • (2002) Anesthesiology , vol.97 , pp. 1338-1349
    • Spahn, D.R.1    Waschke, K.F.2    Standl, T.3    Motsch, J.4    Van Huynegem, L.5    Welte, M.6
  • 45
    • 0028141460 scopus 로고
    • Characterization and mechanism of side-effects of Oxygent HT (highly concentrated fluorocarbon emulsion) in swine
    • S.F. Flaim, D.R. Hazard, J. Hogan, and R.M. Peters Characterization and mechanism of side-effects of Oxygent HT (highly concentrated fluorocarbon emulsion) in swine Artif Cells Blood Substit Immobil Biotechnol 22 1994 1511 1515
    • (1994) Artif Cells Blood Substit Immobil Biotechnol , vol.22 , pp. 1511-1515
    • Flaim, S.F.1    Hazard, D.R.2    Hogan, J.3    Peters, R.M.4
  • 46
    • 0038781759 scopus 로고    scopus 로고
    • Perflubron emulsion in prolonged hemorrhagic shock: Influence on hepatocellular energy metabolism and oxygen-dependent gene expression
    • M. Paxian, H. Rensing, K. Geckeis, I. Bauer, D. Kubulus, and D.R. Spahn Perflubron emulsion in prolonged hemorrhagic shock: influence on hepatocellular energy metabolism and oxygen-dependent gene expression Anesthesiology 98 2003 1391 1399
    • (2003) Anesthesiology , vol.98 , pp. 1391-1399
    • Paxian, M.1    Rensing, H.2    Geckeis, K.3    Bauer, I.4    Kubulus, D.5    Spahn, D.R.6
  • 47
    • 4344577782 scopus 로고    scopus 로고
    • Artificial oxygen carriers as red blood cell substitutes: A selected review and current status
    • H.W. Kim, and A.G. Greenburg Artificial oxygen carriers as red blood cell substitutes: a selected review and current status Artif Organs 28 2004 813 828
    • (2004) Artif Organs , vol.28 , pp. 813-828
    • Kim, H.W.1    Greenburg, A.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.