메뉴 건너뛰기




Volumn 42, Issue 5, 1999, Pages 876-883

Fluctuating equilibrium MRI

Author keywords

Abdominal imaging; Fast imaging; FEMR; Fluctuating equilibrium magnetic resonance; Lipid suppression; Magnetic resonance angiography; MRA; Musculoskeletal imaging; Steady state free precession; T2 contrast

Indexed keywords

ANGIOGRAPHY; BRAIN MAPPING; IMAGE ACQUISITION; MAGNETISM; MUSCULOSKELETAL SYSTEM;

EID: 0032710249     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2594(199911)42:5<876::AID-MRM6>3.0.CO;2-Z     Document Type: Article
Times cited : (85)

References (20)
  • 1
    • 0000369227 scopus 로고
    • Steady-state free precission in nuclear magnetic resonance
    • Carr HY. Steady-state free precission in nuclear magnetic resonance. Phys Rev 1958;112:1693-1701.
    • (1958) Phys Rev , vol.112 , pp. 1693-1701
    • Carr, H.Y.1
  • 2
    • 0016984868 scopus 로고
    • Image-formation by nuclear magnetic-resonance: Sensitive point method
    • Hinshaw WS. Image-formation by nuclear magnetic-resonance: sensitive point method. J Appl Phys 1976;47:3709-3721.
    • (1976) J Appl Phys , vol.47 , pp. 3709-3721
    • Hinshaw, W.S.1
  • 5
    • 0023117716 scopus 로고
    • Rapid Fourier imaging using steady-state free precession
    • Hawkes RC, Patz S. Rapid Fourier imaging using steady-state free precession. Magn Reson Med 1987;4:9-23.
    • (1987) Magn Reson Med , vol.4 , pp. 9-23
    • Hawkes, R.C.1    Patz, S.2
  • 6
    • 0023758588 scopus 로고
    • Clinical experience with rapid 2DFT SSFP imaging at low field strength
    • Jolesz FA, Patz S. Clinical experience with rapid 2DFT SSFP imaging at low field strength. Magn Reson Imaging 1988;6:397-403.
    • (1988) Magn Reson Imaging , vol.6 , pp. 397-403
    • Jolesz, F.A.1    Patz, S.2
  • 7
    • 0023872880 scopus 로고
    • An analysis of fast imaging sequences with steady-state transverse magnetization refocussing
    • Zur Y, Stokar S, Bendel P. An analysis of fast imaging sequences with steady-state transverse magnetization refocussing. Magn Reson Med 1988;6:175-403.
    • (1988) Magn Reson Med , vol.6 , pp. 175-403
    • Zur, Y.1    Stokar, S.2    Bendel, P.3
  • 8
    • 36849112831 scopus 로고
    • Analysis of Carr-Purcell spin-echo NMR experiments on multiple-spin systems. I. The effect of homonuclear coupling
    • Allerhand A. Analysis of Carr-Purcell spin-echo NMR experiments on multiple-spin systems. I. The effect of homonuclear coupling. J Chem Phys 1966;44:1-9.
    • (1966) J Chem Phys , vol.44 , pp. 1-9
    • Allerhand, A.1
  • 10
    • 0029925919 scopus 로고    scopus 로고
    • Coherence transfer by isotropic mixing in Carr-Purcell-Meiboom-Gill imaging: Implications for the bright fat phenomenon in fast spin-echo imaging
    • Williamson DS, Mulkern RV, Jakob PD, Jolesz FA. Coherence transfer by Isotropic mixing in Carr-Purcell-Meiboom-Gill imaging: implications for the bright fat phenomenon in fast spin-echo imaging. Magn Reson Med 1996;35:506-513.
    • (1996) Magn Reson Med , vol.35 , pp. 506-513
    • Williamson, D.S.1    Mulkern, R.V.2    Jakob, P.D.3    Jolesz, F.A.4
  • 12
    • 0030004409 scopus 로고    scopus 로고
    • Fat-suppressed three-dimensional spoiled gradient-echo MR imaging of hyaline cartilage defects in the knee: Comparison with standard mr imaging and arthroscopy
    • Disler DG, McCauley TR, Kelman CG, Fuchs MD, Ratner LM, Wirth CR, Hospodar PP. Fat-suppressed three-dimensional spoiled gradient-echo MR imaging of hyaline cartilage defects in the knee: comparison with standard mr imaging and arthroscopy. Am J Roentgenol 1996;167:127-132.
    • (1996) Am J Roentgenol , vol.167 , pp. 127-132
    • Disler, D.G.1    McCauley, T.R.2    Kelman, C.G.3    Fuchs, M.D.4    Ratner, L.M.5    Wirth, C.R.6    Hospodar, P.P.7
  • 13
    • 0026150599 scopus 로고
    • Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T
    • Wright GA, Hu BS, Macovski A. Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T. J Magn Reson Imaging 1991;1:275-283.
    • (1991) J Magn Reson Imaging , vol.1 , pp. 275-283
    • Wright, G.A.1    Hu, B.S.2    Macovski, A.3
  • 15
    • 0026057828 scopus 로고
    • Flow-independent magnetic resonance projection angiography
    • Wright GA, Nishimura DG, Macovski A. Flow-independent magnetic resonance projection angiography. Magn Reson Med 1991;17:126-140.
    • (1991) Magn Reson Med , vol.17 , pp. 126-140
    • Wright, G.A.1    Nishimura, D.G.2    Macovski, A.3
  • 16
    • 0027349175 scopus 로고
    • Basic physics MR contrast agents and maximization of image contrast
    • Hendrick RE, Haacke EM. Basic physics MR contrast agents and maximization of image contrast. J Magn Reson Imaging 1993;3:137-148.
    • (1993) J Magn Reson Imaging , vol.3 , pp. 137-148
    • Hendrick, R.E.1    Haacke, E.M.2
  • 17
    • 0023367344 scopus 로고
    • Steady-state magnetizations in rapid NMR imaging using small flip angles and short repetition intervals
    • Sekihara K. Steady-state magnetizations in rapid NMR imaging using small flip angles and short repetition intervals. IEEE Trans Med Imaging 1987;6:157-164.
    • (1987) IEEE Trans Med Imaging , vol.6 , pp. 157-164
    • Sekihara, K.1
  • 18
    • 0023280289 scopus 로고
    • Conventional and rapid MR imaging of the liver with Gd-DTPA
    • Hamm B, Wolf KJ, Felix R. Conventional and rapid MR imaging of the liver with Gd-DTPA. Radiology 1987;164:313-320.
    • (1987) Radiology , vol.164 , pp. 313-320
    • Hamm, B.1    Wolf, K.J.2    Felix, R.3
  • 20
    • 0031884958 scopus 로고    scopus 로고
    • Remember true FISP? A high SNR near 1-second imaging method for T2-like contrast in interventional MRI at .2 T
    • Duerk JL, Lewin JS, Wendt M, Petersilge C. Remember true FISP? A high SNR near 1-second imaging method for T2-like contrast in interventional MRI at .2 T. J Magn Reson Imaging 1998;8:203-408.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 203-408
    • Duerk, J.L.1    Lewin, J.S.2    Wendt, M.3    Petersilge, C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.