메뉴 건너뛰기




Volumn 124, Issue 5, 2004, Pages 582-586

Objective measurements of auditory nerve recovery function in nucleus CI 24 implantees in relation to subjective preference of stimulation rate

Author keywords

Auditory nerve recovery time; Auditory evoked compound action potentials; Cochlear implant; Neural response telemetry; Objective fitting of cochlear implant; Refractory recovery function; Speech coding strategies

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; CLINICAL ARTICLE; COCHLEA PROSTHESIS; COCHLEAR NERVE; CONTROLLED STUDY; CONVALESCENCE; ELECTRODE; EVOKED AUDITORY RESPONSE; HEARING LOSS; HUMAN; INNER EAR DISEASE; NERVE FUNCTION; NERVE POTENTIAL; NERVE STIMULATION; NON INVASIVE MEASUREMENT; PRIORITY JOURNAL; RANK SUM TEST; RECIPIENT; SCHOOL CHILD; STATISTICAL SIGNIFICANCE; TELEMETRY;

EID: 3042741213     PISSN: 00016489     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (6)

References (17)
  • 1
    • 0030775214 scopus 로고    scopus 로고
    • Temporal representations with cochlear implants
    • Wilson B, Finley C, Lawson D, Zerbi M. Temporal representations with cochlear implants. Am J Otol 1997; 18(6 Suppl): S30-4.
    • (1997) Am J Otol , vol.18 , Issue.6 SUPPL.
    • Wilson, B.1    Finley, C.2    Lawson, D.3    Zerbi, M.4
  • 2
    • 0342813020 scopus 로고    scopus 로고
    • Optimization of channel number and stimulation rate for the fast continuous interleaved sampling strategy in the COMBI 40+
    • Brill SM, Gstottner W, Helms J, von Ilberg C, Baumgartner W, Muller J, et al. Optimization of channel number and stimulation rate for the fast continuous interleaved sampling strategy in the COMBI 40+. Am J Otol 1997; 18(6 Suppl): S104-6.
    • (1997) Am J Otol , vol.18 , Issue.6 SUPPL.
    • Brill, S.M.1    Gstottner, W.2    Helms, J.3    Von Ilberg, C.4    Baumgartner, W.5    Muller, J.6
  • 3
    • 0033901505 scopus 로고    scopus 로고
    • The effect of parametric variations of cochlear implant processors on speech understanding
    • Loizou PC, Poroy O, Dorman M. The effect of parametric variations of cochlear implant processors on speech understanding. J Acoust Soc Am 2000; 108: 790-802.
    • (2000) J Acoust Soc Am , vol.108 , pp. 790-802
    • Loizou, P.C.1    Poroy, O.2    Dorman, M.3
  • 4
    • 0042531429 scopus 로고    scopus 로고
    • On the relationship between noise and speech perception in cochlear implant subjects: A theoretical and psychophysical study
    • October, Hunt, Texas, USA
    • Collins LM, Miller RL, Ferguson WD. On the relationship between noise and speech perception in cochlear implant subjects: a theoretical and psychophysical study. Ninth Digital Signal processing workshop, October 2000, Hunt, Texas, USA. http://Spib.ece.rice.edu/Dsp2000/program.html
    • (2000) Ninth Digital Signal Processing Workshop
    • Collins, L.M.1    Miller, R.L.2    Ferguson, W.D.3
  • 5
    • 0036775950 scopus 로고    scopus 로고
    • Effects of stimulation rate with the Nucleus 24 ACE speech coding strategy
    • Holden LK, Skinner MW, Holden TA, Demorest ME. Effects of stimulation rate with the Nucleus 24 ACE speech coding strategy. Ear Hear 2002; 23: 463-76.
    • (2002) Ear Hear , vol.23 , pp. 463-476
    • Holden, L.K.1    Skinner, M.W.2    Holden, T.A.3    Demorest, M.E.4
  • 6
    • 0033636134 scopus 로고    scopus 로고
    • Speech perception as a function of electrical stimulation rate: Using the Nucleus 24 cochlear implant system
    • Vandali AE, Whitford LA, Plant KL, Clark GM. Speech perception as a function of electrical stimulation rate: using the Nucleus 24 cochlear implant system. Ear Hear 2000; 21: 608-24.
    • (2000) Ear Hear , vol.21 , pp. 608-624
    • Vandali, A.E.1    Whitford, L.A.2    Plant, K.L.3    Clark, G.M.4
  • 7
    • 0031470082 scopus 로고    scopus 로고
    • Electrode discrimination and speech perception in postlingually deafened adult cochlear implant subjects
    • Zwolan TA, Collins LM, Wakefield GH. Electrode discrimination and speech perception in postlingually deafened adult cochlear implant subjects. J Acoust Soc Am 1997; 102: 3673-85.
    • (1997) J Acoust Soc Am , vol.102 , pp. 3673-3685
    • Zwolan, T.A.1    Collins, L.M.2    Wakefield, G.H.3
  • 8
    • 0025000379 scopus 로고
    • Estimation of surviving spiral ganglion cells in the deaf rat using the electrically evoked auditory brainstem response
    • Hall RD. Estimation of surviving spiral ganglion cells in the deaf rat using the electrically evoked auditory brainstem response. Hear Res 1990; 49: 155-68.
    • (1990) Hear Res , vol.49 , pp. 155-168
    • Hall, R.D.1
  • 9
    • 0030013117 scopus 로고    scopus 로고
    • Electrically evoked whole nerve action potentials in Ineraid cochlear implant users: Responses to different stimulation electrode configurations and comparison to psychophysical results
    • Brown CJ, Abbas PJ, Borland J, Bertschy MR. Electrically evoked whole nerve action potentials in Ineraid cochlear implant users: responses to different stimulation electrode configurations and comparison to psychophysical results. J Speech Hear Res 1996; 39: 453-67.
    • (1996) J Speech Hear Res , vol.39 , pp. 453-467
    • Brown, C.J.1    Abbas, P.J.2    Borland, J.3    Bertschy, M.R.4
  • 10
    • 0035096819 scopus 로고    scopus 로고
    • Comparison of speech recognition with different speech coding strategies (SPEAK, CIS, and ACE) and their relationship to telemetric measures of compound action potentials in the Nucleus CI 24M cochlear implant system
    • Kiefer J, Hohl S, Sturzebecher E, Pfennigdorff T, Gstoettner W. Comparison of speech recognition with different speech coding strategies (SPEAK, CIS, and ACE) and their relationship to telemetric measures of compound action potentials in the Nucleus CI 24M cochlear implant system. Audiology 2001; 40: 32-42.
    • (2001) Audiology , vol.40 , pp. 32-42
    • Kiefer, J.1    Hohl, S.2    Sturzebecher, E.3    Pfennigdorff, T.4    Gstoettner, W.5
  • 11
    • 0032693388 scopus 로고    scopus 로고
    • Neural response telemetry with the Nucleus CI24M cochlear implant
    • Shallop JK, Facer GW, Peterson A. Neural response telemetry with the Nucleus CI24M cochlear implant. Laryngoscope 1999; 109: 1755-9.
    • (1999) Laryngoscope , vol.109 , pp. 1755-1759
    • Shallop, J.K.1    Facer, G.W.2    Peterson, A.3
  • 12
    • 0034113705 scopus 로고    scopus 로고
    • The relationship between EAP and EABR thresholds and levels used to program the Nucleus 24 speech processor: Data from adults
    • Brown CJ, Hughes ML, Luk B, Abbas PJ, Wolaver A, Gervais J. The relationship between EAP and EABR thresholds and levels used to program the Nucleus 24 speech processor: data from adults. Ear Hear 2000; 21: 151-63.
    • (2000) Ear Hear , vol.21 , pp. 151-163
    • Brown, C.J.1    Hughes, M.L.2    Luk, B.3    Abbas, P.J.4    Wolaver, A.5    Gervais, J.6
  • 13
    • 0033042930 scopus 로고    scopus 로고
    • Summary of results using the Nucleus CI24M implant to record the electrically evoked compound action potential
    • Abbas PJ, Brown CJ, Shallop JK, Firszt JB, Hughes ML, Hong SH, et al. Summary of results using the Nucleus CI24M implant to record the electrically evoked compound action potential. Ear Hear 1999; 20: 45-59.
    • (1999) Ear Hear , vol.20 , pp. 45-59
    • Abbas, P.J.1    Brown, C.J.2    Shallop, J.K.3    Firszt, J.B.4    Hughes, M.L.5    Hong, S.H.6
  • 14
    • 0031956190 scopus 로고    scopus 로고
    • Preliminary experience with neural response telemetry in the Nucleus CI24M cochlear implant
    • Brown CJ, Abbas PJ, Gantz BJ. Preliminary experience with neural response telemetry in the Nucleus CI24M cochlear implant. Am J Otol 1998; 19: 320-7.
    • (1998) Am J Otol , vol.19 , pp. 320-327
    • Brown, C.J.1    Abbas, P.J.2    Gantz, B.J.3
  • 15
    • 0031775797 scopus 로고    scopus 로고
    • Intracochlear factors contributing to psychophysical percepts following cochlear implantation
    • Stockh
    • Kawano A, Seldon HL, Clark GM, Ramsden RT, Raine CH. Intracochlear factors contributing to psychophysical percepts following cochlear implantation. Acta Otolaryngol (Stockh) 1998; 118: 313-26.
    • (1998) Acta Otolaryngol , vol.118 , pp. 313-326
    • Kawano, A.1    Seldon, H.L.2    Clark, G.M.3    Ramsden, R.T.4    Raine, C.H.5
  • 17
    • 0025109523 scopus 로고
    • Electrically evoked whole-nerve action potentials: Data from human cochlear implant users
    • Brown CJ, Abbas PJ, Gantz BJ. Electrically evoked whole-nerve action potentials: data from human cochlear implant users. J Acoust Soc Am 1990; 88: 1385-91.
    • (1990) J Acoust Soc Am , vol.88 , pp. 1385-1391
    • Brown, C.J.1    Abbas, P.J.2    Gantz, B.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.