메뉴 건너뛰기




Volumn 5368, Issue 1, 2004, Pages 162-169

Ghosting comparison for large-area selenium detectors suitable for mammography and general radiography

Author keywords

Direct conversion; General radiography; Ghosting; Lag; Mammography; Selenium; Tomosynthesis

Indexed keywords

CHARGE COUPLED DEVICES; CMOS INTEGRATED CIRCUITS; QUANTUM THEORY; SELENIUM; SENSITIVITY ANALYSIS; SINGLE CRYSTALS; X RAY ANALYSIS;

EID: 3042684204     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.535812     Document Type: Conference Paper
Times cited : (23)

References (13)
  • 1
    • 0036575750 scopus 로고    scopus 로고
    • Residual images in charge-coupled device detectors
    • Rest A., Mündermann Widenhorn R., Bodegom E., and McGlinn T., "Residual images in charge-coupled device detectors", 2002, Rev. Sci. Instrum., vol. 73, pp. 2028-2032.
    • (2002) Rev. Sci. Instrum. , vol.73 , pp. 2028-2032
    • Rest, A.1    Mündermann, W.R.2    Bodegom, E.3    McGlinn, T.4
  • 3
    • 0032772594 scopus 로고    scopus 로고
    • A ghost story: Spatio-temporal response characteristics of an indirect-detector flat-panel imager
    • Siewerdsen J.H. and Jaffray D.A., "A ghost story: spatio-temporal response characteristics of an indirect-detector flat-panel imager", Med. Phys. 26, 1999, pp. 1624-1641.
    • (1999) Med. Phys. , vol.26 , pp. 1624-1641
    • Siewerdsen, J.H.1    Jaffray, D.A.2
  • 4
    • 0034870333 scopus 로고    scopus 로고
    • Temporal artifacts in flat dynamic detectors
    • Overdick M., Solf T., and Wischmann H., "Temporal artifacts in flat dynamic detectors", Proc. SPIE vol. 4320, 2001, pp. 47-58.
    • (2001) Proc. SPIE , vol.4320 , pp. 47-58
    • Overdick, M.1    Solf, T.2    Wischmann, H.3
  • 5
    • 0034873663 scopus 로고    scopus 로고
    • Fast imaging of a 41cm amorphous silicon flat-panel detector for radiographic applications
    • Kump K., "Fast Imaging of a 41cm Amorphous Silicon Flat-panel detector for radiographic applications", Proc. SPIE vol. 4320, 2001, pp. 87-93.
    • (2001) Proc. SPIE , vol.4320 , pp. 87-93
    • Kump, K.1
  • 7
    • 0036033452 scopus 로고    scopus 로고
    • Investigation of lag and ghosting in amorphous selenium flat-panel x-ray detectors
    • Zhao W., DeCrescenzo G., and Rowlands J., "Investigation of lag and ghosting in amorphous selenium flat-panel x-ray detectors",2002, Proc. of SPIE, vol. 4682, pp. 9-19
    • (2002) Proc. of SPIE , vol.4682 , pp. 9-19
    • Zhao, W.1    DeCrescenzo, G.2    Rowlands, J.3
  • 8
    • 0036033208 scopus 로고    scopus 로고
    • Characerization of a full field digital mammography detector based on direct x-ray conversion in selenium
    • Yorker J., Jeromine L., Lee D., Palecki E., Golden K., and Jing Z., "Characerization of a full field digital mammography detector based on direct x-ray conversion in selenium", 2002, Proc. of SPIE, vol. 4682, pp. 21-29.
    • (2002) Proc. of SPIE , vol.4682 , pp. 21-29
    • Yorker, J.1    Jeromine, L.2    Lee, D.3    Palecki, E.4    Golden, K.5    Jing, Z.6
  • 12
    • 0032403888 scopus 로고    scopus 로고
    • A new large area x-ray image sensor
    • Ouimette D., Nudelman S., and Aikens R., "A new large area x-ray image sensor", 1998, Proc. Of SPIE, vol. 3336, pp. 470-476.
    • (1998) Proc. Of SPIE , vol.3336 , pp. 470-476
    • Ouimette, D.1    Nudelman, S.2    Aikens, R.3
  • 13
    • 0042376174 scopus 로고    scopus 로고
    • Improvement of the temporal response and output uniformity of polycrystalline CdZnTe films for high sensitivity x-ray imaging
    • Tokuda S., Kishihara H., Adachi S., and Sato T., "Improvement of the temporal response and output uniformity of polycrystalline CdZnTe films for high sensitivity x-ray imaging", 2003, Proc of SPIE, vol. 5030, pp. 861-870.
    • (2003) Proc of SPIE , vol.5030 , pp. 861-870
    • Tokuda, S.1    Kishihara, H.2    Adachi, S.3    Sato, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.