메뉴 건너뛰기




Volumn 12, Issue 1-2 SPEC. ISS., 2005, Pages 44-51

Electronmc Mosquito: Designing a semi-invasive microsystem for blood sampling, analysis and drug delivery applications

Author keywords

Automatic Blood Sampler; BioMEMS; Diabetes; Electronic Mosquito; Microactuator; Microneedle; Microsystem

Indexed keywords

BLOOD; PRODUCT DESIGN;

EID: 30344447285     PISSN: 09467076     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00542-005-0015-9     Document Type: Conference Paper
Times cited : (32)

References (12)
  • 2
    • 0037871729 scopus 로고    scopus 로고
    • Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer
    • Griss P, Stemme G (2003) Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer. J Microelectromech Syst 12:296-301
    • (2003) J Microelectromech Syst , vol.12 , pp. 296-301
    • Griss, P.1    Stemme, G.2
  • 3
    • 0042565830 scopus 로고    scopus 로고
    • A numerical-experimental method to characterize the non-linear mechanical behaviour of human skin
    • Hendriks FM (2003) A numerical-experimental method to characterize the non-linear mechanical behaviour of human skin. Skin Res Technol 9:274-283
    • (2003) Skin Res Technol , vol.9 , pp. 274-283
    • Hendriks, F.M.1
  • 7
    • 0033340381 scopus 로고    scopus 로고
    • Recent developments in micromachined silicon
    • Moore DF, Syms R (1999) Recent developments in micromachined silicon. Electron Commun Eng J 11:261-270
    • (1999) Electron Commun Eng J , vol.11 , pp. 261-270
    • Moore, D.F.1    Syms, R.2
  • 8
    • 0033745074 scopus 로고    scopus 로고
    • Microactuators and their technologies
    • Thielicke E, Obermeier E (2000) Microactuators and their technologies. Mechatronics 10:431-455
    • (2000) Mechatronics , vol.10 , pp. 431-455
    • Thielicke, E.1    Obermeier, E.2
  • 10
    • 71749095646 scopus 로고    scopus 로고
    • Effects of microneedle tip geometry on injection and extraction in the skin
    • 2002
    • Wang PMC, MG; Prausnitz MR (2002) Effects of microneedle tip geometry on injection and extraction in the skin, presented at EMBS/BMES Conference, 2002
    • (2002) EMBS/BMES Conference
    • Wang, P.M.C.1    Prausnitz, M.R.2
  • 11
    • 0030175963 scopus 로고    scopus 로고
    • Glucose monitoring: State of the art and future possibilities
    • Wilkins E, Atanasov P (1996) Glucose monitoring: State of the art and future possibilities. Med Eng Phys 18:273-288
    • (1996) Med Eng Phys , vol.18 , pp. 273-288
    • Wilkins, E.1    Atanasov, P.2
  • 12
    • 0036447617 scopus 로고    scopus 로고
    • Fundamental study on non-invasive blood glucose sensing
    • Xu K, Li Q, Lu Z, Jiang J (2002) Fundamental study on non-invasive blood glucose sensing. J X-Ray Sci Technol 10:187-197
    • (2002) J X-ray Sci Technol , vol.10 , pp. 187-197
    • Xu, K.1    Li, Q.2    Lu, Z.3    Jiang, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.