Volumn 61, Issue 2-3, 2004, Pages 123-127

Efficiency calibration of high volume samples using the GESPECOR software

Author keywords

Detector characterization; Efficiency calibration; Gamma ray spectrometry; Ge detector; Radioactive waste assessment

Indexed keywords

COMPUTER SIMULATION; DETECTORS; ERROR ANALYSIS; GAMMA RAY SPECTROMETERS; MONTE CARLO METHODS; SAMPLING;

EID: 2942610640     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apradiso.2004.03.032     Document Type: Conference Paper
Times cited : (29)

References (12)
  • 1
    • 0034159968 scopus 로고    scopus 로고
    • Coincidence summing in gamma-ray spectrometry by excitation of matrix X-rays
    • Arnold D., Sima O. Coincidence summing in gamma-ray spectrometry by excitation of matrix X-rays. Appl. Radiat. Isot. 52(3):2000;725-732
    • (2000) Appl. Radiat. Isot. , vol.52 , Issue.3 , pp. 725-732
    • Arnold, D.1    Sima, O.2
  • 2
    • 0034159982 scopus 로고    scopus 로고
    • SOLIDANG, a computer code for the computation of the effective solid angle and correction factors for gamma spectroscopy-based waste assay
    • Bruggeman M., Carchon R. SOLIDANG, a computer code for the computation of the effective solid angle and correction factors for gamma spectroscopy-based waste assay. Appl. Radiat. Isot. 52(3):2000;771-776
    • (2000) Appl. Radiat. Isot. , vol.52 , Issue.3 , pp. 771-776
    • Bruggeman, M.1    Carchon, R.2
  • 3
    • 0032986788 scopus 로고    scopus 로고
    • A minimum biased shell-source method for the calibration of rad waste assay systems
    • Bruggeman M., Gerits J., Carchon R. A minimum biased shell-source method for the calibration of rad waste assay systems. Appl. Radiat. Isot. 51(3):1999;255-259
    • (1999) Appl. Radiat. Isot. , vol.51 , Issue.3 , pp. 255-259
    • Bruggeman, M.1    Gerits, J.2    Carchon, R.3
  • 5
    • 0029032431 scopus 로고
    • Relation between the activity of a high-density waste drum and its gamma count rate measured with an unshielded Ge-detector
    • Filss P. Relation between the activity of a high-density waste drum and its gamma count rate measured with an unshielded Ge-detector. Appl. Radiat. Isot. 46(8):1995;805-812
    • (1995) Appl. Radiat. Isot. , vol.46 , Issue.8 , pp. 805-812
    • Filss, P.1
  • 6
    • 0030200607 scopus 로고    scopus 로고
    • A theoretical investigation of calibration methods for radwaste radioactivity detection systems
    • Liang J.H., Jiang S.H., Chou G.T. A theoretical investigation of calibration methods for radwaste radioactivity detection systems. Appl. Radiat. Isot. 47(7):1996;669-675
    • (1996) Appl. Radiat. Isot. , vol.47 , Issue.7 , pp. 669-675
    • Liang, J.H.1    Jiang, S.H.2    Chou, G.T.3
  • 7
    • 0032053428 scopus 로고    scopus 로고
    • Parametric study of shell-source method for calibrating radwaste radioactivity detection systems
    • Liang J.H., Jiang S.H., Chou J.T., Chen C.C., Lin S.W., Lee C.H., Chiou S.T. Parametric study of shell-source method for calibrating radwaste radioactivity detection systems. Appl. Radiat. Isot. 49(4):1998;361-368
    • (1998) Appl. Radiat. Isot. , vol.49 , Issue.4 , pp. 361-368
    • Liang, J.H.1    Jiang, S.H.2    Chou, J.T.3    Chen, C.C.4    Lin, S.W.5    Lee, C.H.6    Chiou, S.T.7
  • 9
    • 0030250078 scopus 로고    scopus 로고
    • Self-attenuation and coincidence-summing corrections calculated by Monte Carlo simulations for gamma spectrometric measurements with well type germanium detectors
    • Sima O., Arnold D. Self-attenuation and coincidence-summing corrections calculated by Monte Carlo simulations for gamma spectrometric measurements with well type germanium detectors. Appl. Radiat. Isot. 47(9-10):1996;889-893
    • (1996) Appl. Radiat. Isot. , vol.47 , Issue.910 , pp. 889-893
    • Sima, O.1    Arnold, D.2
  • 10
    • 0034662358 scopus 로고    scopus 로고
    • Accurate computation of coincidence summing corrections in low level gamma-ray spectrometry
    • Sima O., Arnold D. Accurate computation of coincidence summing corrections in low level gamma-ray spectrometry. Appl. Radiat. Isot. 53(1-2):2000;51-56
    • (2000) Appl. Radiat. Isot. , vol.53 , Issue.12 , pp. 51-56
    • Sima, O.1    Arnold, D.2
  • 11
    • 0031036779 scopus 로고    scopus 로고
    • Matrix effects in the activity measurement of environmental samples. Implementation of specific corrections in a gamma-ray spectrometry analysis program
    • Sima O., Dovlete C. Matrix effects in the activity measurement of environmental samples. Implementation of specific corrections in a gamma-ray spectrometry analysis program. Appl. Radiat. Isot. 48(1):1997;59-69
    • (1997) Appl. Radiat. Isot. , vol.48 , Issue.1 , pp. 59-69
    • Sima, O.1    Dovlete, C.2
  • 12
    • 0034973151 scopus 로고    scopus 로고
    • GESPECOR: A versatile tool in gamma ray spectrometry
    • Sima O., Arnold D., Dovlete C. GESPECOR. a versatile tool in gamma ray spectrometry J. Radioanal. Nucl. Chem. 248(2):2001;359-364
    • (2001) J. Radioanal. Nucl. Chem. , vol.248 , Issue.2 , pp. 359-364
    • Sima, O.1    Arnold, D.2    Dovlete, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.