메뉴 건너뛰기




Volumn 52, Issue 3, 2000, Pages 725-732

Coincidence-summing in gamma-ray spectrometry by excitation of matrix X- rays

Author keywords

Characteristic X rays; Coincidence summing; Monte Carlo calculation; spectrometry

Indexed keywords

GAMMA RAY SPECTROMETERS; MONTE CARLO METHODS; PLUTONIUM COMPOUNDS; RADIATION DETECTORS; SELENIUM; SOLUTIONS; SPECTRUM ANALYSIS; WATER;

EID: 0034159968     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0969-8043(99)00236-5     Document Type: Article
Times cited : (17)

References (11)
  • 3
    • 0011696902 scopus 로고
    • Tables and graphs of photon-interaction cross sections from 10 eV to 100 GeV derived from the LLNL evaluated photon data library (EPDL)
    • Rev. 4.
    • Cullen, D.E., Chen, M.H., Hubbell, J.H., Perkins, S.T., Plecahty, E.F., Rathkopf, J.A., Scofield, J.H., 1989. Tables and graphs of photon-interaction cross sections from 10 eV to 100 GeV derived from the LLNL evaluated photon data library (EPDL), UCRL-50400, vol. 6, Rev. 4.
    • (1989) UCRL-50400 , vol.6
    • Cullen, D.E.1    Chen, M.H.2    Hubbell, J.H.3    Perkins, S.T.4    Plecahty, E.F.5    Rathkopf, J.A.6    Scofield, J.H.7
  • 4
    • 0018293171 scopus 로고
    • Coincidence summing corrections in Ge(Li)-spectrometry at low source-to-detector distances
    • Debertin K., Schötzig U. Coincidence summing corrections in Ge(Li)-spectrometry at low source-to-detector distances. Nucl. Instrum. Methods A. 158:1979;471.
    • (1979) Nucl. Instrum. Methods a , vol.158 , pp. 471
    • Debertin, K.1    Schötzig, U.2
  • 5
    • 0000254615 scopus 로고
    • Coincidence-summing corrections for extended sources in gamma-ray spectrometry using Monte Carlo simulation
    • Décombaz M., Gostely J.-J., Laedermann J.-P. Coincidence-summing corrections for extended sources in gamma-ray spectrometry using Monte Carlo simulation. Nucl. Instrum. Methods Phys. Res. A. 312:1992;152.
    • (1992) Nucl. Instrum. Methods Phys. Res. a , vol.312 , pp. 152
    • Décombaz, M.1    Gostely, J.-J.2    Laedermann, J.-P.3
  • 6
    • 0029872624 scopus 로고    scopus 로고
    • Evaluation of Monte Carlo simulation of photon counting efficiency for germanium detectors
    • Kamboj S., Kahn B. Evaluation of Monte Carlo simulation of photon counting efficiency for germanium detectors. Health Phys. 70:1996;512.
    • (1996) Health Phys. , vol.70 , pp. 512
    • Kamboj, S.1    Kahn, B.2
  • 7
    • 0042630355 scopus 로고
    • Tables and graphs of electron-interaction cross sections from 10 eV to 100 GeV derived from the LLNL evaluated electron data library (EEDL)
    • Perkins, S.T., Cullen, D.E., Seltzer, S.M., 1991. Tables and graphs of electron-interaction cross sections from 10 eV to 100 GeV derived from the LLNL evaluated electron data library (EEDL), UCRL-50400, vol. 31.
    • (1991) UCRL-50400 , vol.31
    • Perkins, S.T.1    Cullen, D.E.2    Seltzer, S.M.3
  • 8
    • 0030249359 scopus 로고    scopus 로고
    • Applications of Monte Carlo calculations to gamma-spectrometric measurements of environmental samples
    • Sima O. Applications of Monte Carlo calculations to gamma-spectrometric measurements of environmental samples. Appl. Radiat. Isot. 47:1996;919.
    • (1996) Appl. Radiat. Isot. , vol.47 , pp. 919
    • Sima, O.1
  • 9
    • 0030250078 scopus 로고    scopus 로고
    • Self-attenuation and coincidence-summing corrections calculated by Monte Carlo simulations for gamma-spectrometric measurements with well-type germanium detectors
    • Sima O., Arnold D. Self-attenuation and coincidence-summing corrections calculated by Monte Carlo simulations for gamma-spectrometric measurements with well-type germanium detectors. Appl. Radiat. Isot. 47:1996;889.
    • (1996) Appl. Radiat. Isot. , vol.47 , pp. 889
    • Sima, O.1    Arnold, D.2
  • 10
    • 0031036779 scopus 로고    scopus 로고
    • Matrix effects in the activity measurement of environmental samples - Implementation of specific corrections in a gamma-ray spectrometry analysis program
    • Sima O., Dovlete C. Matrix effects in the activity measurement of environmental samples - Implementation of specific corrections in a gamma-ray spectrometry analysis program. Appl. Radiat. Isot. 48:1997;59.
    • (1997) Appl. Radiat. Isot. , vol.48 , pp. 59
    • Sima, O.1    Dovlete, C.2
  • 11
    • 0003896525 scopus 로고    scopus 로고
    • Document CEA-ISBN 27272 02008
    • Table de Radionucléides, 1999. Document CEA-ISBN 27272 02008.
    • (1999) Table de Radionucléides


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.