메뉴 건너뛰기




Volumn 53, Issue 1-2, 2000, Pages 51-56

Accurate computation of coincidence summing corrections in low level gamma-ray spectrometry

Author keywords

Coincidence summing; Efficiency calibration; Germanium detectors; Low level gamma ray spectrometry

Indexed keywords

COMPUTER SOFTWARE; ERROR CORRECTION; GAMMA RAY SPECTROMETERS; MEASUREMENT ERRORS; PARTICLE DETECTORS;

EID: 0034662358     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0969-8043(00)00113-5     Document Type: Conference Paper
Times cited : (76)

References (7)
  • 1
    • 0034159968 scopus 로고    scopus 로고
    • Coincidence-summing in gamma-ray spectrometry by excitation of matrix X-rays
    • Arnold, D., Sima, O., 2000. Coincidence-summing in gamma-ray spectrometry by excitation of matrix X-rays. Appl. Radiat. Isot. 52, 725-732.
    • (2000) Appl. Radiat. Isot. , vol.52 , pp. 725-732
    • Arnold, D.1    Sima, O.2
  • 2
    • 0018293171 scopus 로고
    • Coincidence summing corrections in Ge(Li)-spectrometry at low source-to-detector distances
    • Debertin K., Schötzig U. Coincidence summing corrections in Ge(Li)-spectrometry at low source-to-detector distances. Nucl. Instrum. and Meth. 158:1979;471-477.
    • (1979) Nucl. Instrum. and Meth. , vol.158 , pp. 471-477
    • Debertin, K.1    Schötzig, U.2
  • 5
    • 0030249359 scopus 로고    scopus 로고
    • Applications of Monte Carlo calculations to gamma-spectrometric measurements of environmental samples
    • Sima O. Applications of Monte Carlo calculations to gamma-spectrometric measurements of environmental samples. Appl. Radiat. Isot. 47:1996;919-923.
    • (1996) Appl. Radiat. Isot. , vol.47 , pp. 919-923
    • Sima, O.1
  • 6
    • 0030250078 scopus 로고    scopus 로고
    • Self-attenuation and coincidence-summing corrections calculated by Monte Carlo simulations for gamma-spectrometric measurements with well-type germanium detector
    • Sima O., Arnold D. Self-attenuation and coincidence-summing corrections calculated by Monte Carlo simulations for gamma-spectrometric measurements with well-type germanium detector. Appl. Radiat. Isot. 47:1996;889-893.
    • (1996) Appl. Radiat. Isot. , vol.47 , pp. 889-893
    • Sima, O.1    Arnold, D.2
  • 7
    • 0031036779 scopus 로고    scopus 로고
    • Matrix effects in the activity measurement of environmental samples: Implementation of specific corrections in a gamma-ray analysis program
    • Sima O., Dovlete C. Matrix effects in the activity measurement of environmental samples: implementation of specific corrections in a gamma-ray analysis program. Appl. Radiat. Isot. 48:1997;59-69.
    • (1997) Appl. Radiat. Isot. , vol.48 , pp. 59-69
    • Sima, O.1    Dovlete, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.