메뉴 건너뛰기




Volumn 19, Issue 5, 2004, Pages 433-447

Strain and force transducers used in human and veterinary tendon and ligament biomechanical studies

Author keywords

Force; Ligament; Strain; Tendon; Transducer

Indexed keywords

ELECTRIC RESISTANCE; HALL EFFECT; LIGAMENTS; OPTICAL FIBERS; STRAIN GAGES; TENDONS; TRANSDUCERS;

EID: 2942519298     PISSN: 02680033     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clinbiomech.2004.01.008     Document Type: Article
Times cited : (61)

References (59)
  • 1
    • 0015973055 scopus 로고
    • In vivo tendon tension and bone strain measurement and correlation
    • Barnes G.R., Pinder D.N. in vivo tendon tension and bone strain measurement and correlation. J. Biomech. 7:1974;35-42
    • (1974) J. Biomech. , vol.7 , pp. 35-42
    • Barnes, G.R.1    Pinder, D.N.2
  • 2
    • 0022708543 scopus 로고
    • Design and performance of a modified buckle transducer for the measurement of ligament tension
    • Barry D., Ahmed A.M. Design and performance of a modified buckle transducer for the measurement of ligament tension. J. Biomech. Eng. 108:1986;149-152
    • (1986) J. Biomech. Eng. , vol.108 , pp. 149-152
    • Barry, D.1    Ahmed, A.M.2
  • 3
    • 0022591312 scopus 로고
    • Dynamic performance characteristics of the liquid metal strain gauge
    • Brown T.D., et al. Dynamic performance characteristics of the liquid metal strain gauge. J. Biomech. 19:1986;165-173
    • (1986) J. Biomech. , vol.19 , pp. 165-173
    • Brown, T.D.1
  • 4
    • 2942607337 scopus 로고
    • Measurement of in vitro patellar tendon forces
    • Butler D.L., et al. Measurement of in vitro patellar tendon forces. ASME Adv. Bioeng. 15:1989;111-112
    • (1989) ASME Adv. Bioeng. , vol.15 , pp. 111-112
    • Butler, D.L.1
  • 5
    • 2942605774 scopus 로고    scopus 로고
    • In vitro evaluation of a fiberoptic transducer for tendon force measurements
    • Zürick, Switzerland
    • Erdemir, A. et al., 2001. In vitro evaluation of a fiberoptic transducer for tendon force measurements. In: XVII Congress of the International Society of Biomechanics, Zürick, Switzerland. p. 165
    • (2001) XVII Congress of the International Society of Biomechanics , pp. 165
    • Erdemir, A.1
  • 6
    • 0036000235 scopus 로고    scopus 로고
    • Influence of loading rate and cable migration on fiberoptic measurement of tendon force
    • Erdemir A., et al. Influence of loading rate and cable migration on fiberoptic measurement of tendon force. J. Biomech. 35:2002;857-862
    • (2002) J. Biomech. , vol.35 , pp. 857-862
    • Erdemir, A.1
  • 7
    • 0031933178 scopus 로고    scopus 로고
    • Achilles tendon loading during walking: Application of a novel optic fiber technique
    • Finni T., et al. Achilles tendon loading during walking: application of a novel optic fiber technique. Eur. J. Appl. Physiol. 83:1998;289-291
    • (1998) Eur. J. Appl. Physiol. , vol.83 , pp. 289-291
    • Finni, T.1
  • 8
    • 0034534074 scopus 로고    scopus 로고
    • In vivo human triceps surae and quadriceps femoris muscle function in a squat jump and counter movement jump
    • Finni T., et al. In vivo human triceps surae and quadriceps femoris muscle function in a squat jump and counter movement jump. Eur. J. Appl. Physiol. 83:2000;416-426
    • (2000) Eur. J. Appl. Physiol. , vol.83 , pp. 416-426
    • Finni, T.1
  • 9
    • 0028533679 scopus 로고
    • Determination of a zero strain reference for the anteromedial band of the anterior cruciate ligament
    • Fleming B.C., et al. Determination of a zero strain reference for the anteromedial band of the anterior cruciate ligament. J. Orthop. Res. 12:1994;789-795
    • (1994) J. Orthop. Res. , vol.12 , pp. 789-795
    • Fleming, B.C.1
  • 10
    • 0039330460 scopus 로고    scopus 로고
    • Measurement of anterior cruciate ligament (ACL) graft loads using an arthroscopic implantable force probe
    • Orthopaedic Research Society, Atlanta, Georgia
    • Fleming, B.C. et al., 1996. Measurement of anterior cruciate ligament (ACL) graft loads using an arthroscopic implantable force probe. In: 42nd annual Meeting, Orthopaedic Research Society, Atlanta, Georgia, p. 75
    • (1996) 42nd Annual Meeting , pp. 75
    • Fleming, B.C.1
  • 11
    • 0034021223 scopus 로고    scopus 로고
    • Factors influencing the output of an implantable force transducer
    • Fleming B.C., et al. Factors influencing the output of an implantable force transducer. J. Biomech. 33:2000;889-893
    • (2000) J. Biomech. , vol.33 , pp. 889-893
    • Fleming, B.C.1
  • 12
    • 0027506067 scopus 로고
    • Comparison between the directly measured achilles tendon force and the tendon force calculated from the ankle joint moment during vertical jumps
    • Fukashiro S., et al. Comparison between the directly measured achilles tendon force and the tendon force calculated from the ankle joint moment during vertical jumps. Clin. Biomech. 8:1993;25-30
    • (1993) Clin. Biomech. , vol.8 , pp. 25-30
    • Fukashiro, S.1
  • 13
    • 84873205300 scopus 로고
    • Pressure vs deflected beam force measurement in the human patellar tendon
    • Orthopaedic Research Society, New Orleans, Louisiana
    • Glos, D.L. et al., 1990. Pressure vs deflected beam force measurement in the human patellar tendon. In: 36th annual Meeting, Orthopaedic Research Society, New Orleans, Louisiana, p. 490
    • (1990) 36th Annual Meeting , pp. 490
    • Glos, D.L.1
  • 14
    • 0027703506 scopus 로고
    • In vitro evaluation of an implantable force transducer (IFT) in a patellar tendon model
    • Glos D.L., et al. In vitro evaluation of an implantable force transducer (IFT) in a patellar tendon model. J. Biomech. Eng. 115:1993;335-343
    • (1993) J. Biomech. Eng. , vol.115 , pp. 335-343
    • Glos, D.L.1
  • 15
    • 0023128104 scopus 로고
    • Achilles tendon forces during cycling
    • Gregor R.J., et al. Achilles tendon forces during cycling. Int. J. Sports Med. 8(suppl.):1987;9-14
    • (1987) Int. J. Sports Med. , vol.8 , Issue.SUPPL. , pp. 9-14
    • Gregor, R.J.1
  • 16
    • 0023809451 scopus 로고
    • Force-velocity potentiation in cat soleus muscle during treadmill locomotion
    • Gregor R.J., et al. Force-velocity potentiation in cat soleus muscle during treadmill locomotion. J. Biomech. 21:1988;721-732
    • (1988) J. Biomech. , vol.21 , pp. 721-732
    • Gregor, R.J.1
  • 17
    • 0025920047 scopus 로고
    • A comparison of the triceps surae and residual muscle moments at the ankle during cycling
    • Gregor R.J., et al. A comparison of the triceps surae and residual muscle moments at the ankle during cycling. J. Biomech. 24:1991;287-297
    • (1991) J. Biomech. , vol.24 , pp. 287-297
    • Gregor, R.J.1
  • 18
    • 0033080799 scopus 로고    scopus 로고
    • Rate-independent characteristics of an arthroscopically implantable force probe in the human Achilles tendon
    • Hall G.W., et al. Rate-independent characteristics of an arthroscopically implantable force probe in the human Achilles tendon. J. Biomech. 32:1999;203-207
    • (1999) J. Biomech. , vol.32 , pp. 203-207
    • Hall, G.W.1
  • 19
    • 0344836061 scopus 로고    scopus 로고
    • Quantification of in vivo patellofemoral contact forces before and after ACL transection
    • Hasler E.M., Herzog W. Quantification of in vivo patellofemoral contact forces before and after ACL transection. J. Biomech. 31:1997;37-44
    • (1997) J. Biomech. , vol.31 , pp. 37-44
    • Hasler, E.M.1    Herzog, W.2
  • 20
    • 0018037777 scopus 로고
    • A study of the normal range of strain, strain rate and stiffness of tendon
    • Herrick W.C., et al. A study of the normal range of strain, strain rate and stiffness of tendon. J. Biomech. Mater. Res. 12:1978;877-894
    • (1978) J. Biomech. Mater. Res. , vol.12 , pp. 877-894
    • Herrick, W.C.1
  • 21
    • 0030032281 scopus 로고    scopus 로고
    • Evaluation of the implantable force transducer for chronic tendon-force recordings
    • Herzog W., et al. Evaluation of the implantable force transducer for chronic tendon-force recordings. J. Biomech. 29:1996;103-109
    • (1996) J. Biomech. , vol.29 , pp. 103-109
    • Herzog, W.1
  • 22
    • 0030560666 scopus 로고    scopus 로고
    • In-situ calibration of the implantable force transducer
    • Herzog W., et al. In-situ calibration of the implantable force transducer. J. Biomech. 29:1996;1649-1652
    • (1996) J. Biomech. , vol.29 , pp. 1649-1652
    • Herzog, W.1
  • 23
    • 0028434083 scopus 로고
    • In vivo forces in the anterior cruciate ligament: Direct measurements during walking and trotting in a quadruped
    • Holden J.P., et al. In vivo forces in the anterior cruciate ligament: direct measurements during walking and trotting in a quadruped. J. Biomech. 27:1994;517-526
    • (1994) J. Biomech. , vol.27 , pp. 517-526
    • Holden, J.P.1
  • 24
    • 0028958365 scopus 로고
    • Factors affecting sensitivity of a transducer for measuring anterior cruciate ligament force
    • Holden J.P., et al. Factors affecting sensitivity of a transducer for measuring anterior cruciate ligament force. J. Biomech. 28:1995;99-102
    • (1995) J. Biomech. , vol.28 , pp. 99-102
    • Holden, J.P.1
  • 25
    • 0025070976 scopus 로고
    • Arthroscopic strain gauge measurement of the normal anterior cruciate ligament
    • Howe J.G., et al. Arthroscopic strain gauge measurement of the normal anterior cruciate ligament. Arthroscopy. 6:1990;198-204
    • (1990) Arthroscopy , vol.6 , pp. 198-204
    • Howe, J.G.1
  • 26
    • 0027230054 scopus 로고
    • In vivo tendon forces in the forelimb of ponies at the walk, validated by ground reaction forces measurements
    • Jansen M.O., et al. In vivo tendon forces in the forelimb of ponies at the walk, validated by ground reaction forces measurements. Acta Anat. 146:1993;162-167
    • (1993) Acta Anat. , vol.146 , pp. 162-167
    • Jansen, M.O.1
  • 27
    • 0027264606 scopus 로고
    • Strain of the musculus interosseus medius and its rami extensorii in the horse, deduced from in vivo kinematics
    • Jansen M.O., et al. Strain of the musculus interosseus medius and its rami extensorii in the horse, deduced from in vivo kinematics. Acta Anat. 147:1993;118-124
    • (1993) Acta Anat. , vol.147 , pp. 118-124
    • Jansen, M.O.1
  • 28
    • 0032073458 scopus 로고    scopus 로고
    • Mechanical properties of the tendinous equine interosseus affected by in vivo transducer implantation
    • Jansen M.O., et al. Mechanical properties of the tendinous equine interosseus affected by in vivo transducer implantation. J. Biomech. 31:1998;485-490
    • (1998) J. Biomech. , vol.31 , pp. 485-490
    • Jansen, M.O.1
  • 29
    • 0016831221 scopus 로고
    • A method for recording tendon strain in sheep during locomotion
    • Kear M., Smith R.N. A method for recording tendon strain in sheep during locomotion. Acta Orthop. Scand. 46:1975;896-905
    • (1975) Acta Orthop. Scand. , vol.46 , pp. 896-905
    • Kear, M.1    Smith, R.N.2
  • 30
    • 0040367184 scopus 로고
    • Measurement of suspensory ligament strain using a liquid mercury strain gauge: Evaluation of strain reduction by support bandaging and alteration of hoof wall angle
    • San Francisco, California (1991-1992).
    • Keegan, K.G. et al., 1991. Measurement of suspensory ligament strain using a liquid mercury strain gauge: evaluation of strain reduction by support bandaging and alteration of hoof wall angle. In: Proceedings of the 37th Annual Convention of the American Association of Equine Practitioners, San Francisco, California (1991-1992). pp. 243-244
    • (1991) Proceedings of the 37th Annual Convention of the American Association of Equine Practitioners , pp. 243-244
    • Keegan, K.G.1
  • 31
    • 0026890643 scopus 로고
    • Evaluation of support bandaging during measurement of proximal sesamoidean strain in horses by use of a mercury strain gauge
    • Keegan K.G., et al. Evaluation of support bandaging during measurement of proximal sesamoidean strain in horses by use of a mercury strain gauge. Am. J. Vet. Res. 53:1992;1203-1208
    • (1992) Am. J. Vet. Res. , vol.53 , pp. 1203-1208
    • Keegan, K.G.1
  • 32
    • 0025668479 scopus 로고
    • Relevance of in vivo force measurements to human biomechanics
    • Komi P.V. Relevance of in vivo force measurements to human biomechanics. J. Biomech. 23(suppl. 1):1990;23-24
    • (1990) J. Biomech. , vol.23 , Issue.SUPPL. 1 , pp. 23-24
    • Komi, P.V.1
  • 33
    • 0011185718 scopus 로고
    • In vivo measurements of Achilles tendon forces in man. ACSM Annual Meeting abstracts
    • Komi P.V., et al. In vivo measurements of Achilles tendon forces in man. ACSM Annual Meeting abstracts. Med. Sci. Sports Exercise. 16:1984;165-166
    • (1984) Med. Sci. Sports Exercise. , vol.16 , pp. 165-166
    • Komi, P.V.1
  • 34
    • 0023094793 scopus 로고
    • In vivo registration of Achilles tendon forces in man. I. Methodological development
    • Komi P.V., et al. In vivo registration of Achilles tendon forces in man. I. Methodological development. Int. J. Sports Med. 8:1987;3-8
    • (1987) Int. J. Sports Med. , vol.8 , pp. 3-8
    • Komi, P.V.1
  • 35
    • 0030047304 scopus 로고    scopus 로고
    • Optic fibre as a transducer of tendomuscular forces
    • Komi P.V., et al. Optic fibre as a transducer of tendomuscular forces. Eur. J. Appl. Physiol. 72:1996;278-280
    • (1996) Eur. J. Appl. Physiol. , vol.72 , pp. 278-280
    • Komi, P.V.1
  • 36
    • 0030131107 scopus 로고    scopus 로고
    • The use of an implantable force transducer to measure patellar tendon forces in goats
    • Korvick D.L., et al. The use of an implantable force transducer to measure patellar tendon forces in goats. J. Biomech. 29:1996;557-561
    • (1996) J. Biomech. , vol.29 , pp. 557-561
    • Korvick, D.L.1
  • 37
    • 0020134577 scopus 로고
    • A note on the application and evaluation of the buckle transducer for knee ligament force measurement
    • Lewis J.L., et al. A note on the application and evaluation of the buckle transducer for knee ligament force measurement. J. Biomech. Eng. 104:1982;125-128
    • (1982) J. Biomech. Eng. , vol.104 , pp. 125-128
    • Lewis, J.L.1
  • 38
    • 0019289210 scopus 로고
    • In vivo and in vitro measurement of tendon strain in the horse
    • Lochner F.K., et al. In vivo and in vitro measurement of tendon strain in the horse. Am. J. Vet. Res. 41:1980;1929-1937
    • (1980) Am. J. Vet. Res. , vol.41 , pp. 1929-1937
    • Lochner, F.K.1
  • 39
    • 0032124930 scopus 로고    scopus 로고
    • In situ calibration of miniature sensors implanted into the anterior cruciate ligament. Part I: Strain measurements
    • Marlkof K.L., et al. In situ calibration of miniature sensors implanted into the anterior cruciate ligament. Part I: Strain measurements. J. Orthop. Res. 16:1998;455-463
    • (1998) J. Orthop. Res. , vol.16 , pp. 455-463
    • Marlkof, K.L.1
  • 40
    • 0032124605 scopus 로고    scopus 로고
    • In situ calibration of miniature sensors implanted into the anterior cruciate ligament. Part II: Force probe measurements
    • Marlkof K.L., et al. In situ calibration of miniature sensors implanted into the anterior cruciate ligament. Part II: Force probe measurements. J. Orthop. Res. 16:1998;464-471
    • (1998) J. Orthop. Res. , vol.16 , pp. 464-471
    • Marlkof, K.L.1
  • 41
    • 2942572740 scopus 로고
    • An investigation of the biomechanics of equine flexor tendon loading using a implantable micro force transducer
    • Aarhus, Denmark, July 8-11
    • Platt, D. et al., 1990. An investigation of the biomechanics of equine flexor tendon loading using a implantable micro force transducer. In: 7th Meeting of the European Society of Biomechanics, Aarhus, Denmark, July 8-11
    • (1990) 7th Meeting of the European Society of Biomechanics
    • Platt, D.1
  • 42
    • 0028630508 scopus 로고
    • Novel force transducer for the measurement of tendon force in vivo
    • Platt D., et al. Novel force transducer for the measurement of tendon force in vivo. J. Biomech. 27:1994;1489-1493
    • (1994) J. Biomech. , vol.27 , pp. 1489-1493
    • Platt, D.1
  • 44
    • 0023948402 scopus 로고
    • Calibration of the mercury-in-silastic strain gauge in tendon load experiments
    • Riemersma D.J., Lammertink J.L.M.A. Calibration of the mercury-in-silastic strain gauge in tendon load experiments. J. Biomech. 21:1988;469-476
    • (1988) J. Biomech. , vol.21 , pp. 469-476
    • Riemersma, D.J.1    Lammertink, J.L.M.A.2
  • 45
    • 0024059636 scopus 로고
    • Kinetics and kinematics of the equine hindleg, I: In vivo tendon load and force plate measurements
    • Riemersma D.J., et al. Kinetics and kinematics of the equine hindleg, I: In vivo tendon load and force plate measurements. Am. J. Vet. Res. 49:1988;1344-1352
    • (1988) Am. J. Vet. Res. , vol.49 , pp. 1344-1352
    • Riemersma, D.J.1
  • 46
    • 0024059831 scopus 로고
    • Kinetics and kinematics of the equine hindleg, II: In vivo tendon strain and joint kinematics
    • Riemersma D.J., et al. Kinetics and kinematics of the equine hindleg, II: In vivo tendon strain and joint kinematics. Am. J. Vet. Res. 49:1988;1353-1359
    • (1988) Am. J. Vet. Res. , vol.49 , pp. 1353-1359
    • Riemersma, D.J.1
  • 47
    • 0030097130 scopus 로고    scopus 로고
    • Tendon strain in the forelimbs as a function of gait and ground characteristics and in vitro limb loading in ponies
    • Riemersma D.J., et al. Tendon strain in the forelimbs as a function of gait and ground characteristics and in vitro limb loading in ponies. Equine Vet. J. 28:1996;133-138
    • (1996) Equine Vet. J. , vol.28 , pp. 133-138
    • Riemersma, D.J.1
  • 48
    • 0030097038 scopus 로고    scopus 로고
    • Influence of shoeing on ground reaction forces and tendon strains in the forelimbs of ponies
    • Riemersma D.J., et al. Influence of shoeing on ground reaction forces and tendon strains in the forelimbs of ponies. Equine Vet. J. 28:1996;126-132
    • (1996) Equine Vet. J. , vol.28 , pp. 126-132
    • Riemersma, D.J.1
  • 49
    • 0002203233 scopus 로고
    • In-vivo measurement of human anterior cruciate ligament forces during knee extension exercises
    • Orthopaedic Research Society, New Orleans, Louisiana
    • Roberts, C.S. et al., 1994. In-vivo measurement of human anterior cruciate ligament forces during knee extension exercises. In: 40th Annual Meeting, Orthopaedic Research Society, New Orleans, Louisiana, p. 84
    • (1994) 40th Annual Meeting , pp. 84
    • Roberts, C.S.1
  • 50
    • 0032411731 scopus 로고    scopus 로고
    • Influence of sensor size on the accuracy of in vivo ligament and tendon force measurements
    • Rupert M., et al. Influence of sensor size on the accuracy of in vivo ligament and tendon force measurements. J. Biomech. Eng. 120:1998;764-769
    • (1998) J. Biomech. Eng. , vol.120 , pp. 764-769
    • Rupert, M.1
  • 51
    • 0345054912 scopus 로고
    • The 8th international conference on medical and biological engineering, Meeting report
    • Salmons S. The 8th international conference on medical and biological engineering, Meeting report. Biomed. Eng. 4:1969;467-474
    • (1969) Biomed. Eng. , vol.4 , pp. 467-474
    • Salmons, S.1
  • 52
    • 0021065856 scopus 로고
    • Correlation of myoelectric activity and muscle force during selected cat treadmill locomotion
    • Sherif M.H., et al. Correlation of myoelectric activity and muscle force during selected cat treadmill locomotion. J. Biomech. 16:1983;691-701
    • (1983) J. Biomech. , vol.16 , pp. 691-701
    • Sherif, M.H.1
  • 53
    • 0020794943 scopus 로고
    • A clinical and experimental study of tendon injury, healing and treatment in the horse
    • Silver I.A., Rossdale P.D. A clinical and experimental study of tendon injury, healing and treatment in the horse. Equine Vet. J. (suppl. 1):1983;1-43
    • (1983) Equine Vet. J. , Issue.1 SUPPL. , pp. 1-43
    • Silver, I.A.1    Rossdale, P.D.2
  • 54
    • 0024697022 scopus 로고
    • Application of Hall-effect transducer for measurement of tendon strains in horses
    • Stephens P.R., et al. Application of Hall-effect transducer for measurement of tendon strains in horses. Am. J. Vet. Res. 50:1989;1089-1095
    • (1989) Am. J. Vet. Res. , vol.50 , pp. 1089-1095
    • Stephens, P.R.1
  • 55
    • 0020765646 scopus 로고
    • Developments in the design and use of liquid-metal strain gauges
    • Stone J.E., et al. Developments in the design and use of liquid-metal strain gauges. Exper. Mech. (June):1983;129-139
    • (1983) Exper. Mech. , Issue.JUNE , pp. 129-139
    • Stone, J.E.1
  • 57
    • 0026954925 scopus 로고
    • A kinematic and strain gauge study of the reciprocal apparatus in the equine hind limb
    • Van Weeren P.R., et al. A kinematic and strain gauge study of the reciprocal apparatus in the equine hind limb. J. Biomech. 25:1992;1291-1301
    • (1992) J. Biomech. , vol.25 , pp. 1291-1301
    • Van Weeren, P.R.1
  • 58
    • 0018075476 scopus 로고
    • Forces produced by the medial gastrocnemius and soleus muscles during locomotion in freely moving cats
    • Walmsley B., et al. Forces produced by the medial gastrocnemius and soleus muscles during locomotion in freely moving cats. J. Neurophysiol. 41:1978;535-577
    • (1978) J. Neurophysiol. , vol.41 , pp. 535-577
    • Walmsley, B.1
  • 59
    • 0026645476 scopus 로고
    • Theoretical analysis of an implantable force transducer for tendon and ligament structures
    • Xu W.S., et al. Theoretical analysis of an implantable force transducer for tendon and ligament structures. J. Biomech. Eng. 114:1992;170-177
    • (1992) J. Biomech. Eng. , vol.114 , pp. 170-177
    • Xu, W.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.