메뉴 건너뛰기




Volumn 31, Issue 5, 1998, Pages 485-490

Mechanical Properties of the tendinous equine interosseus muscle are affected by in vivo transducer implantation

Author keywords

[No Author keywords available]

Indexed keywords

FAILURE (MECHANICAL); IMPLANTS (SURGICAL); MATHEMATICAL MODELS; MUSCLE; PHYSIOLOGY; STRAIN GAGES; TENSILE TESTING; TRANSDUCERS; TWO DIMENSIONAL;

EID: 0032073458     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0021-9290(98)00023-2     Document Type: Article
Times cited : (15)

References (13)
  • 1
    • 0005281505 scopus 로고
    • The forelimb of the horse
    • Pedersen, D., Wonsiewicz, C. (Eds.), Saunders, Philadelphia
    • Dyce, K.M., Sack, W.O., Wensing, C.J.G., 1987. The forelimb of the horse. In: Pedersen, D., Wonsiewicz, C. (Eds.), Textbook of Veterinary Anatomy, pp. 559-567. Saunders, Philadelphia.
    • (1987) Textbook of Veterinary Anatomy , pp. 559-567
    • Dyce, K.M.1    Sack, W.O.2    Wensing, C.J.G.3
  • 2
    • 0344914710 scopus 로고
    • Tendon and ligament injuries
    • Jones, W.E. (Ed.), Lea & Febiger, Philadelphia
    • Genovese, R.L., Simpson, B.S., 1989. Tendon and ligament injuries. In: Jones, W.E. (Ed.), Equine Sportsmedicine. Lea & Febiger, Philadelphia, pp. 241-248.
    • (1989) Equine Sportsmedicine , pp. 241-248
    • Genovese, R.L.1    Simpson, B.S.2
  • 3
    • 0027230054 scopus 로고
    • In vivo tendon forces in the forelimb of ponies at the walk, validated by ground reaction force measurements
    • Jansen, M.O., Bogert, A.J. van den, Riemersma, D.J., Schamhardt, H.C, 1993a. In vivo tendon forces in the forelimb of ponies at the walk, validated by ground reaction force measurements. Acta Anatomica 146, 162-167.
    • (1993) Acta Anatomica , vol.146 , pp. 162-167
    • Jansen, M.O.1    Van Den Bogert, A.J.2    Riemersma, D.J.3    Schamhardt, H.C.4
  • 4
    • 0027264606 scopus 로고
    • Strain of the M. interosseous medius and its Rami extensorii in the horse, deduced from in vivo kinematics
    • Jansen, M.O., Buiten, A. van, Bogert, A.J. van den, Schamhardt, H.C., 1993b. Strain of the M. interosseous medius and its Rami extensorii in the horse, deduced from in vivo kinematics. Acta Anatomica 147, 118-124.
    • (1993) Acta Anatomica , vol.147 , pp. 118-124
    • Jansen, M.O.1    Van Buiten, A.2    Van Den Bogert, A.J.3    Schamhardt, H.C.4
  • 8
    • 0022155717 scopus 로고
    • In vitro mechanical properties of equine tendons in relation to cross-sectional area and collagen content
    • Riemersma, D.J., Schamhardt H.C., 1985. In vitro mechanical properties of equine tendons in relation to cross-sectional area and collagen content. Research in Veterinary Science 39, 263-270.
    • (1985) Research in Veterinary Science , vol.39 , pp. 263-270
    • Riemersma, D.J.1    Schamhardt, H.C.2
  • 9
    • 0023948402 scopus 로고
    • Calibration of the mercury-in-Silastic strain gauge in tendon load experiments
    • Riemersma, D.J., Lammertink, J.L.M.A., 1988. Calibration of the mercury-in-Silastic strain gauge in tendon load experiments. Journal of Biomechanics 20, 469-476.
    • (1988) Journal of Biomechanics , vol.20 , pp. 469-476
    • Riemersma, D.J.1    Lammertink, J.L.M.A.2
  • 13
    • 0017482248 scopus 로고
    • A post mortem study of equine digital flexor tendons
    • Webbon, P.M., 1977. A post mortem study of equine digital flexor tendons. Equine Veterinary Journal 9, 61-67.
    • (1977) Equine Veterinary Journal , vol.9 , pp. 61-67
    • Webbon, P.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.