Rate-independent characteristics of an arthroscopically implantable force probe in the human achilles tendon

Author keywords

Calibration; Force; Implant; Tendon; Transducer

Indexed keywords

CADAVERIC EXPERIMENTS; CALIBRATION; COMPRESSIVE STRESS; FORCE MEASUREMENT; IMPLANTS (SURGICAL); SENSORS; STRAIN GAGES; TENDONS; TENSILE STRESS; TRANSDUCERS;

EID: 0033080799     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0021-9290(98)00167-5     Document Type: Article
Times cited : (19)

References (7)
  • 1
    • 0039330460 scopus 로고    scopus 로고
    • Measurement of anterior cruciate ligament (ACL) graft loads using an arthroscopic implantable force probe
    • Atlanta, Georgia
    • Fleming, B., Good, L., Peura, G., Beynnon, B.D., 1996. Measurement of anterior cruciate ligament (ACL) graft loads using an arthroscopic implantable force probe. Proceedings of the 42nd ORS Conference, Atlanta, Georgia, pp. 75-13.
    • (1996) Proceedings of the 42nd ORS Conference , pp. 75-13
    • Fleming, B.1    Good, L.2    Peura, G.3    Beynnon, B.D.4
  • 2
    • 0027703506 scopus 로고
    • In Vitro Evaluation of an Implantable Force Transducer (IFT) in a Patellar Tendon Model
    • Gloss D., Butler D., Grood E., Levy M. In Vitro Evaluation of an Implantable Force Transducer (IFT) in a Patellar Tendon Model. Journal of Biomechanical Engineering. 115:1993;335-343.
    • (1993) Journal of Biomechanical Engineering , vol.115 , pp. 335-343
    • Gloss, D.1    Butler, D.2    Grood, E.3    Levy, M.4
  • 3
    • 0030032281 scopus 로고    scopus 로고
    • Evaluation of the implantable force transducer for chronic tendon-force recordings
    • Herzog W., Archambault J., Leonard T., Nguyen H. Evaluation of the implantable force transducer for chronic tendon-force recordings. Journal of Biomechanics. 29:1996;103-109.
    • (1996) Journal of Biomechanics , vol.29 , pp. 103-109
    • Herzog, W.1    Archambault, J.2    Leonard, T.3    Nguyen, H.4
  • 4
    • 0030560666 scopus 로고    scopus 로고
    • In-situ calibration of the implantable force transducer
    • Herzog W., Hasler E., Leonard T. In-situ calibration of the implantable force transducer. Journal of Biomechanics. 29:1996;1649-1652.
    • (1996) Journal of Biomechanics , vol.29 , pp. 1649-1652
    • Herzog, W.1    Hasler, E.2    Leonard, T.3
  • 5
    • 0031039780 scopus 로고    scopus 로고
    • Comment on "the use of an implantable force transducer to measure patellar tendon forces in goats"
    • Herzog W., Hasler E. Comment on "The use of an implantable force transducer to measure patellar tendon forces in goats" Journal of Biomechanics. 30:1997;303.
    • (1997) Journal of Biomechanics , vol.30 , pp. 303
    • Herzog, W.1    Hasler, E.2
  • 6
    • 0002203233 scopus 로고
    • In-vivo measurement of human anterior cruciate ligament forces during knee extension exercises
    • New Orleans, Louisiana
    • Roberts, C., Cummings, J., Grood, E., Noyes, F., 1994. In-vivo measurement of human anterior cruciate ligament forces during knee extension exercises. Proceedings of the 40th ORS Conference, New Orleans, Louisiana, pp. 84-15.
    • (1994) Proceedings of the 40th ORS Conference , pp. 84-15
    • Roberts, C.1    Cummings, J.2    Grood, E.3    Noyes, F.4
  • 7
    • 0026645476 scopus 로고
    • Theoretical analysis of an implantable force transducer for tendon and ligament structures
    • Xu W., Butler D., Stouffer D., Grood E., Glos D. Theoretical analysis of an implantable force transducer for tendon and ligament structures. Journal of Biomechanical Engineering. 114(2):1992;171-177.
    • (1992) Journal of Biomechanical Engineering , vol.114 , Issue.2 , pp. 171-177
    • Xu, W.1    Butler, D.2    Stouffer, D.3    Grood, E.4    Glos, D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.