Thermal profile of a high-density data center: Hot spot heat fluxes of 512 W/ft2

Author keywords

[No Author keywords available]

Indexed keywords

AIRFLOW; DATA CENTER; INLET AIR TEMPERATURES;

EID: 29144443613     PISSN: 00012505     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (27)

References (10)
  • 1
    • 4344572635 scopus 로고    scopus 로고
    • Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE. 2004. Thermal Guidelines for Data Processing Environments. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • (2004) Thermal Guidelines for Data Processing Environments
  • 2
    • 25844468162 scopus 로고    scopus 로고
    • Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • ASHRAE. 2005. Datacom Equipment Power Trends and Cooling Applications. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • (2005) Datacom Equipment Power Trends and Cooling Applications
  • 3
    • 0035364736 scopus 로고    scopus 로고
    • A methodology for the design of perforated tiles in raised floor data centers using computational flow analysis
    • Kang, S., R. Schmidt, K. Kelkar, and S. Patankar. 2001. A methodology for the design of perforated tiles in raised floor data centers using computational flow analysis. IEEE-CPMT Journal 24(2): 177-183.
    • (2001) IEEE-CPMT Journal , vol.24 , Issue.2 , pp. 177-183
    • Kang, S.1    Schmidt, R.2    Kelkar, K.3    Patankar, S.4
  • 5
    • 20344374995 scopus 로고    scopus 로고
    • Thermal profile of a high density data center - Methodology to thermally characterize a data center
    • Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • Schmidt, R.R. 2004. Thermal profile of a high density data center - Methodology to thermally characterize a data center. ASHRAE Transactions 110(2). Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
    • (2004) ASHRAE Transactions , vol.110 , Issue.2
    • Schmidt, R.R.1
  • 6
    • 5844384521 scopus 로고    scopus 로고
    • Thermal management of office data processing centers. Advances in Electronic Packaging 1997
    • EEP, Kohala Coast, Hawaii, June 15-19, 1997
    • Schmidt, R. 1997. Thermal management of office data processing centers. Advances in Electronic Packaging 1997 (Proceedings of the Pacific Rim/ASME International Electronic Packaging Technical Conference, INTER pack '97), Vol. 2, EEP-Vol 19-2, Kohala Coast, Hawaii, June 15-19, 1997, pp. 1995-2010.
    • (1997) Proceedings of the Pacific Rim/ASME International Electronic Packaging Technical Conference, INTER Pack '97 , vol.2-19 , Issue.2 , pp. 1995-2010
    • Schmidt, R.1
  • 8
    • 0036455474 scopus 로고    scopus 로고
    • Raised floor computer data center: Effect on rack inlet temperatures of exiting both the hot and cold aisle
    • San Diego
    • Schmidt, R., and E. Cruz. 2002. Raised floor computer data center: Effect on rack inlet temperatures of exiting both the hot and cold aisle. Itherm Conference, San Diego, pp. 580-594.
    • (2002) Itherm Conference , pp. 580-594
    • Schmidt, R.1    Cruz, E.2
  • 9
    • 29144529113 scopus 로고    scopus 로고
    • Controlling air leakage from raised access floor cavities
    • 11-08-02
    • Tate Access Floors. 2002. Technical Bulletin #216, Controlling air leakage from raised access floor cavities, 11-08-02.
    • (2002) Technical Bulletin #216 , vol.216


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.