Volumn 80, Issue 6, 2005, Pages 2132-2140

Perioperative patency of coronary artery bypass grafting is not influenced by off-pump technique

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; AORTA BALLOON; ARTICLE; CARDIOPULMONARY BYPASS; CLINICAL EXAMINATION; COMPARATIVE STUDY; CONTROLLED STUDY; CORONARY ARTERY BLOOD FLOW; CORONARY ARTERY BYPASS GRAFT; ECHOCARDIOGRAPHY; ENZYMATIC ASSAY; FEMALE; FLOW MEASUREMENT; GRAFT PATENCY; HEART INFARCTION; HEART MUSCLE REVASCULARIZATION; HOSPITALIZATION; HUMAN; INTERNAL MAMMARY ARTERY; INTRAOPERATIVE PERIOD; LENGTH OF STAY; MAJOR CLINICAL STUDY; MALE; MORTALITY; OFF PUMP CORONARY SURGERY; PERIOPERATIVE PERIOD; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; RADIAL ARTERY; SAPHENOUS VEIN GRAFT; STATISTICAL SIGNIFICANCE; SURGICAL TECHNIQUE; VASCULAR LESION; VEIN ANASTOMOSIS;

EID: 28344449344     PISSN: 00034975     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.athoracsur.2005.05.075     Document Type: Article
Times cited : (14)

References (24)
  • 1
    • 9144230128 scopus 로고    scopus 로고
    • A randomized comparison of off-pump and on-pump multivessel coronary artery bypass surgery
    • N.E. Khan, A. De Souza, R. Mister A randomized comparison of off-pump and on-pump multivessel coronary artery bypass surgery N Engl J Med 350 2004 21 28
    • (2004) N Engl J Med , vol.350 , pp. 21-28
    • Khan, N.E.1    De Souza, A.2    Mister, R.3
  • 4
    • 0032169739 scopus 로고    scopus 로고
    • Transit time flow measurement for detection of early graft failure during myocardial revascularisation
    • B.H. Walpoth, A. Bosshard, T. Genyk Transit time flow measurement for detection of early graft failure during myocardial revascularisation Ann Thorac Surg 66 1998 1097 1100
    • (1998) Ann Thorac Surg , vol.66 , pp. 1097-1100
    • Walpoth, B.H.1    Bosshard, A.2    Genyk, T.3
  • 5
    • 0034773860 scopus 로고    scopus 로고
    • Relation of intraoperative flow measurement with postoperative quantitative angiographic assessment of coronary artery bypass grafting
    • Y. Takami, H. Ina Relation of intraoperative flow measurement with postoperative quantitative angiographic assessment of coronary artery bypass grafting Ann Thorac Surg 72 2001 1270 1274
    • (2001) Ann Thorac Surg , vol.72 , pp. 1270-1274
    • Takami, Y.1    Ina, H.2
  • 7
    • 0032787973 scopus 로고    scopus 로고
    • Off-pump revascularization of the circumflex artery: Technical aspect and short-term results
    • R. Cartier, R. Blain Off-pump revascularization of the circumflex artery technical aspect and short-term results Ann Thorac Surg 68 1999 94 99
    • (1999) Ann Thorac Surg , vol.68 , pp. 94-99
    • Cartier, R.1    Blain, R.2
  • 8
    • 0033790709 scopus 로고    scopus 로고
    • Analysis of hemodynamic changes during beating heart surgical procedure
    • M. Mathison, J.R. Edgerton, J.L. Horswell Analysis of hemodynamic changes during beating heart surgical procedure Ann Thorac Surg 70 2000 1355 1361
    • (2000) Ann Thorac Surg , vol.70 , pp. 1355-1361
    • Mathison, M.1    Edgerton, J.R.2    Horswell, J.L.3
  • 9
    • 0036267167 scopus 로고    scopus 로고
    • Hemodynamic collapse during off-pump coronary artery bypass grafting
    • T.A. Vassiliades, J.L. Nielsen, J.L. Lonquist Hemodynamic collapse during off-pump coronary artery bypass grafting Ann Thorac Surg 73 2002 1874 1879
    • (2002) Ann Thorac Surg , vol.73 , pp. 1874-1879
    • Vassiliades, T.A.1    Nielsen, J.L.2    Lonquist, J.L.3
  • 10
    • 0030447517 scopus 로고    scopus 로고
    • Intermittent antegrade warm blood cardioplegia in aortic valve replacement
    • A.M. Calafiore, G. Teodori, G. Bosco Intermittent antegrade warm blood cardioplegia in aortic valve replacement J Card Surg 11 1996 348 354
    • (1996) J Card Surg , vol.11 , pp. 348-354
    • Calafiore, A.M.1    Teodori, G.2    Bosco, G.3
  • 11
    • 0031664414 scopus 로고    scopus 로고
    • Coronary bypass flow during use of intraaortic balloon pumping and left ventricular assist device
    • T. Tedoriya, M. Kawasuji, N. Sakakibara, H. Takemura, Y. Watanabe, R. Hetzer Coronary bypass flow during use of intraaortic balloon pumping and left ventricular assist device Ann Thorac Surg 66 1998 477 481
    • (1998) Ann Thorac Surg , vol.66 , pp. 477-481
    • Tedoriya, T.1    Kawasuji, M.2    Sakakibara, N.3    Takemura, H.4    Watanabe, Y.5    Hetzer, R.6
  • 12
    • 16644371681 scopus 로고    scopus 로고
    • Perioperative enoximone infusion improves cardiac release after CABG
    • F. Onorati, A. Renzulli, M. De Feo Perioperative enoximone infusion improves cardiac release after CABG J Cardiothorac Vasc Anesth 18 2004 409 414
    • (2004) J Cardiothorac Vasc Anesth , vol.18 , pp. 409-414
    • Onorati, F.1    Renzulli, A.2    De Feo, M.3
  • 13
    • 0027996367 scopus 로고
    • Use of cardiac troponin I to diagnose perioperative myocardial infarction in coronary artery bypass grafting
    • J. Mair, C. Larue, P. Mair, D. Balogh, C. Calzolari, B. Puschendorf Use of cardiac troponin I to diagnose perioperative myocardial infarction in coronary artery bypass grafting Clin Chem 40 1994 2066 2070
    • (1994) Clin Chem , vol.40 , pp. 2066-2070
    • Mair, J.1    Larue, C.2    Mair, P.3    Balogh, D.4    Calzolari, C.5    Puschendorf, B.6
  • 14
    • 5444269236 scopus 로고    scopus 로고
    • The role of gene therapy for intimal hyperplasia of bypass grafts
    • D.G. Cable, J.A. Caccitolo, N. Caplice The role of gene therapy for intimal hyperplasia of bypass grafts Circulation 100 1999 392 395
    • (1999) Circulation , vol.100 , pp. 392-395
    • Cable, D.G.1    Caccitolo, J.A.2    Caplice, N.3
  • 15
    • 0030836465 scopus 로고    scopus 로고
    • Clinical importance of measuring coronary graft flows in the revascularized heart: Ultrasonic or electromagnetic?
    • C.C. Canver, S.D. Cooler, E.L. Murray Clinical importance of measuring coronary graft flows in the revascularized heart ultrasonic or electromagnetic? J Cardiovasc Surg 38 1997 211 215
    • (1997) J Cardiovasc Surg , vol.38 , pp. 211-215
    • Canver, C.C.1    Cooler, S.D.2    Murray, E.L.3
  • 17
    • 0016772252 scopus 로고
    • Effect of blood flow rate on subendothelial proliferation in venous autografts used as arterial substitutes
    • S.L. Faulkner, R.D. Fisher, D.M. Conkle, D.L. Page, H.W. Bender Jr Effect of blood flow rate on subendothelial proliferation in venous autografts used as arterial substitutes Circulation 52 suppl I 1975 163 172
    • (1975) Circulation , vol.52 , Issue.1 SUPPL. , pp. 163-172
    • Faulkner, S.L.1    Fisher, R.D.2    Conkle, D.M.3    Page, D.L.4    Bender Jr., H.W.5
  • 18
    • 0018148667 scopus 로고
    • Velocity distribution and intimal proliferation in autologous vein grafts in dogs
    • S.E. Rittgers, P.E. Karayannacos, J.F. Guy Velocity distribution and intimal proliferation in autologous vein grafts in dogs Circ Res 42 1978 792 801
    • (1978) Circ Res , vol.42 , pp. 792-801
    • Rittgers, S.E.1    Karayannacos, P.E.2    Guy, J.F.3
  • 19
    • 0032212765 scopus 로고    scopus 로고
    • Can visual assessment of flow waveform morphology detedt anastomotic error in off pump coronary artery bypass grafting?
    • S.F. Jaber, S.C. Koenig, B. Bhasker Rao, D.J. Van Himbergen, P.A. Spence Can visual assessment of flow waveform morphology detedt anastomotic error in off pump coronary artery bypass grafting? Eur J Cardiothorac Surg 14 1998 476 479
    • (1998) Eur J Cardiothorac Surg , vol.14 , pp. 476-479
    • Jaber, S.F.1    Koenig, S.C.2    Bhasker Rao, B.3    Van Himbergen, D.J.4    Spence, P.A.5
  • 20
    • 0032794852 scopus 로고    scopus 로고
    • Neural network pattern recognition analysis of garft flow characteristics improves intra-operative anastomotic error detection in minimally invasive CABG
    • P.B. Cerrito, S.C. Koenig, S.C. Koenig Neural network pattern recognition analysis of garft flow characteristics improves intra-operative anastomotic error detection in minimally invasive CABG Eur J Cardiothorac Surg 16 1999 88 93
    • (1999) Eur J Cardiothorac Surg , vol.16 , pp. 88-93
    • Cerrito, P.B.1    Koenig, S.C.2    Koenig, S.C.3
  • 22
    • 0035163511 scopus 로고    scopus 로고
    • Intraoperative assessment of coronary artery bypass graft: Transit-time flowmetry versus angiography
    • H. Shin, R. Yozu, A. Mitsumaru Intraoperative assessment of coronary artery bypass graft transit-time flowmetry versus angiography Ann Thorac Surg 72 2001 1562 1565
    • (2001) Ann Thorac Surg , vol.72 , pp. 1562-1565
    • Shin, H.1    Yozu, R.2    Mitsumaru, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.