메뉴 건너뛰기




Volumn 14, Issue 6, 2005, Pages 573-578

Use of home blood-pressure monitoring in the detection, treatment and surveillance of hypertension

Author keywords

Blood pressure; Blood pressure control; Home blood pressure monitoring; Hypertension

Indexed keywords

ANXIETY; BLOOD PRESSURE MEASUREMENT; BLOOD PRESSURE MONITORING; BLOOD PRESSURE REGULATION; CARDIOVASCULAR RISK; DEVICE; HEALTH CARE; HEALTH CARE COST; HOME MONITORING; HUMAN; HYPERTENSION; MANOMETRY; PATIENT COMPLIANCE; PATIENT EDUCATION; PRACTICE GUIDELINE; PREDICTION; PRIORITY JOURNAL; PROGNOSIS; REVIEW; SCREENING; STETHOSCOPE; STROKE; TELEMETRY;

EID: 27544511419     PISSN: 10624821     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.mnh.0000182531.02945.de     Document Type: Review
Times cited : (8)

References (56)
  • 1
    • 15044342662 scopus 로고    scopus 로고
    • Monitoring in chronic disease: A rational approach
    • Glasziou P, Irwig L, Mant D. Monitoring in chronic disease: a rational approach. BMJ 2005; 330:644-648. An excellent article that reminds us of the rationale for monitoring a chronic disease.
    • (2005) BMJ , vol.330 , pp. 644-648
    • Glasziou, P.1    Irwig, L.2    Mant, D.3
  • 2
    • 0031756870 scopus 로고    scopus 로고
    • Variability of blood pressure
    • Pickering TG. Variability of blood pressure. Blood Press Monit 1998; 3:141-145.
    • (1998) Blood Press Monit , vol.3 , pp. 141-145
    • Pickering, T.G.1
  • 3
    • 0037432311 scopus 로고    scopus 로고
    • Isolated ambulatory hypertension predicts cardiovascular morbidity in elderly men
    • Bjorklund K, Lind L, Zethelius B, et al. Isolated ambulatory hypertension predicts cardiovascular morbidity in elderly men. Circulation 2003; 107:1297-1302.
    • (2003) Circulation , vol.107 , pp. 1297-1302
    • Bjorklund, K.1    Lind, L.2    Zethelius, B.3
  • 4
    • 1542401212 scopus 로고    scopus 로고
    • Cardiovascular prognosis of 'masked hypertension' detected by blood pressure self-measurement in elderly treated hypertensive patients
    • Bobne G, Chatellier G, Genes N, et al. Cardiovascular prognosis of 'masked hypertension' detected by blood pressure self-measurement in elderly treated hypertensive patients. JAMA 2004; 291:1342-1349. Large prospective cohort study of 4939 patients >60 years of age followed up for a mean of 3.2 years. Home BP, self-measured, had better prognostic value (cardiovascular mortality) than office BP.
    • (2004) JAMA , vol.291 , pp. 1342-1349
    • Bobne, G.1    Chatellier, G.2    Genes, N.3
  • 5
    • 21044459001 scopus 로고    scopus 로고
    • Prevalence and clinical significance of a greater ambulatory versus office blood pressure ('reversed white coat' condition) in a general population
    • Bombelli M, Sega R, Facchetti R, et al. Prevalence and clinical significance of a greater ambulatory versus office blood pressure ('reversed white coat' condition) in a general population. J Hypertens 2005; 23:513-520.
    • (2005) J Hypertens , vol.23 , pp. 513-520
    • Bombelli, M.1    Sega, R.2    Facchetti, R.3
  • 6
    • 13844322457 scopus 로고    scopus 로고
    • Detection of masked hypertension by home blood pressure measurement: Is the number of measurements and important issue
    • Mallion JM, Genes N, Vaur L, et al. Detection of masked hypertension by home blood pressure measurement: is the number of measurements and important issue. Blood Press Monit 2004; 9:301-305. This study in 4939 treated hypertensives ≤60 years of age showed that masked hypertension was present in 9.4% of the group and could be diagnosed by self-measured BP using a validated device in the morning and evening for 2 days.
    • (2004) Blood Press Monit , vol.9 , pp. 301-305
    • Mallion, J.M.1    Genes, N.2    Vaur, L.3
  • 7
    • 0037300145 scopus 로고    scopus 로고
    • Determinants of white-coat syndrome assessed by ambulatory blood pressure or self-measured blood pressure
    • Den Hond E, Celis H, Vandenhoven G, et al. Determinants of white-coat syndrome assessed by ambulatory blood pressure or self-measured blood pressure. Blood Press Monit 2003; 8:37-40.
    • (2003) Blood Press Monit , vol.8 , pp. 37-40
    • Den Hond, E.1    Celis, H.2    Vandenhoven, G.3
  • 8
    • 0015420608 scopus 로고
    • A sphygmomanometer in every home
    • Burch GE. A sphygmomanometer in every home. Am Heart J 1972; 84:710.
    • (1972) Am Heart J , vol.84 , pp. 710
    • Burch, G.E.1
  • 9
    • 5044232954 scopus 로고    scopus 로고
    • Practical aspect of monitoring hypertension based on self-measured blood pressure at home
    • Imai Y, Ohkubo T, Kikuya M, Hashimoto J. Practical aspect of monitoring hypertension based on self-measured blood pressure at home. Int Med 2004; 43:771-778. A recent review article that contains a useful summary of the recommendations for measuring home BP.
    • (2004) Int Med , vol.43 , pp. 771-778
    • Imai, Y.1    Ohkubo, T.2    Kikuya, M.3    Hashimoto, J.4
  • 10
    • 17844409323 scopus 로고    scopus 로고
    • A survey of validated automated home blood pressure monitors available for the Internet shopper
    • Graves JW. A survey of validated automated home blood pressure monitors available for the Internet shopper. Blood Press Monit 2005; 10:103-107. Fifty percent of automatic BP machines available of the Internet were not validated and, if they were, this information was not clearly stated. Additionally, larger cuffs were optional, not always available and increased the purchase cost.
    • (2005) Blood Press Monit , vol.10 , pp. 103-107
    • Graves, J.W.1
  • 11
    • 5644258726 scopus 로고    scopus 로고
    • Home blood pressure measurement and its relationship with blood pressure control in a large selected hypertensive population
    • Cuspidi C, Meani S, Fusi V, et al. Home blood pressure measurement and its relationship with blood pressure control in a large selected hypertensive population. J Hum Hypertens 2004; 18:725-731. This study demonstrates that home BP monitoring is performed by 66% of hypertensive patients attending an out-patient hospital clinic and that those undertaking home BP monitoring had better rates of BP control. Also shows that age, male gender and educational level influence the use of home BP monitoring.
    • (2004) J Hum Hypertens , vol.18 , pp. 725-731
    • Cuspidi, C.1    Meani, S.2    Fusi, V.3
  • 12
    • 3042788931 scopus 로고    scopus 로고
    • Accuracy of home blood pressure readings: Monitors and operators
    • Stryker T, Wilson M, Wilson TW. Accuracy of home blood pressure readings: monitors and operators. Blood Press Monit 2004; 9:143-147. Identifies that most patients had never been taught the correct technique and shows that a simple education programme can correct mistakes and improve accuracy.
    • (2004) Blood Press Monit , vol.9 , pp. 143-147
    • Stryker, T.1    Wilson, M.2    Wilson, T.W.3
  • 13
    • 0034028579 scopus 로고    scopus 로고
    • Guidelines for the use of self-blood pressure monitoring: A summary report of the first international consensus international conference
    • Asmar R, Zanchetti A. Guidelines for the use of self-blood pressure monitoring: a summary report of the first international consensus international conference. J Hypertens 2000; 18:493-508.
    • (2000) J Hypertens , vol.18 , pp. 493-508
    • Asmar, R.1    Zanchetti, A.2
  • 14
    • 0037527647 scopus 로고    scopus 로고
    • European Society of Hypertension-European Society of Cardiology guidelines for the management of arterial hypertension
    • European Society of Hypertension-European Society of Cardiology Guidelines Committee. European Society of Hypertension-European Society of Cardiology guidelines for the management of arterial hypertension. J Hypertens 2003; 21:1011-1053.
    • (2003) J Hypertens , vol.21 , pp. 1011-1053
  • 15
    • 1542432170 scopus 로고    scopus 로고
    • Guidelines for management of hypertension: Report of the fourth working party of the British Hypertension Society, 2004-BHS IV
    • Williams B, Poulter NR, Brown MJ, et al. Guidelines for management of hypertension: report of the fourth working party of the British Hypertension Society, 2004-BHS IV. J Hum Hypertens 2004; 18:139-185.
    • (2004) J Hum Hypertens , vol.18 , pp. 139-185
    • Williams, B.1    Poulter, N.R.2    Brown, M.J.3
  • 16
    • 7744234536 scopus 로고    scopus 로고
    • Centre for Health Services Research. Report no. 111. Newcastle: University of Newcastle
    • North of England Hypertension Guideline Development Group. Essential hypertension: managing adult patients in primary care. Centre for Health Services Research. Report no. 111. Newcastle: University of Newcastle, 2004.
    • (2004) Essential Hypertension: Managing Adult Patients in Primary Care
  • 17
    • 0142012292 scopus 로고    scopus 로고
    • Home of self blood pressure measurement? What is the correct term?
    • Stergious GS, Efstanthiou SP, Alamara CV, et al. Home of self blood pressure measurement? What is the correct term? J Hypertens 2003; 21:2259-2264.
    • (2003) J Hypertens , vol.21 , pp. 2259-2264
    • Stergious, G.S.1    Efstanthiou, S.P.2    Alamara, C.V.3
  • 18
    • 0037258507 scopus 로고    scopus 로고
    • Blood pressure measurement in an ambulatory setting: Concordance between physician and patient self-measurement
    • Vinyoles E, Biancafort X, Lopez-Quinones C, et al. Blood pressure measurement in an ambulatory setting: concordance between physician and patient self-measurement. J Hum Hypertens 2003; 17:45-50.
    • (2003) J Hum Hypertens , vol.17 , pp. 45-50
    • Vinyoles, E.1    Biancafort, X.2    Lopez-Quinones, C.3
  • 19
    • 20244382998 scopus 로고    scopus 로고
    • Practice guidelines of the European Society of Hypertension for clinic, ambulatory and self blood pressure measurement
    • O'Brien E, Asmar R, Beilin L, et al. Practice guidelines of the European Society of Hypertension for clinic, ambulatory and self blood pressure measurement. J Hypertens 2005; 23:697-701. Excellent short review containing practical guidelines for BP measurement.
    • (2005) J Hypertens , vol.23 , pp. 697-701
    • O'Brien, E.1    Asmar, R.2    Beilin, L.3
  • 20
    • 13444255966 scopus 로고    scopus 로고
    • Recommendations for blood pressure measurement in humans and experimental animals
    • Pickering TG, Hall JE, Appel LJ, et al. Recommendations for blood pressure measurement in humans and experimental animals. Circulation 2005; 111:697-716. Excellent up-to-date review of the current literature.
    • (2005) Circulation , vol.111 , pp. 697-716
    • Pickering, T.G.1    Hall, J.E.2    Appel, L.J.3
  • 21
    • 0035799041 scopus 로고    scopus 로고
    • Blood pressure measuring devices: Recommendations of the European Society of Hypertension
    • O'Brien E, Waeber B, Parati G, et al. Blood pressure measuring devices: recommendations of the European Society of Hypertension. BMJ 2001; 322:531-536.
    • (2001) BMJ , vol.322 , pp. 531-536
    • O'Brien, E.1    Waeber, B.2    Parati, G.3
  • 22
    • 0142061633 scopus 로고    scopus 로고
    • A website for blood pressure monitoring devices: Dableducational.com
    • O'Brien E. A website for blood pressure monitoring devices: dableducational.com. Blood Press Monit 2003; 8:177-180.
    • (2003) Blood Press Monit , vol.8 , pp. 177-180
    • O'Brien, E.1
  • 23
    • 2642542406 scopus 로고    scopus 로고
    • Self blood pressure measurement at home: How many times?
    • Parati G, Stergiou G. Self blood pressure measurement at home: how many times? J Hypertens 2004; 22:1075-1079. Recent editorial summarizing the literature with regard to how often BP should be self-measured.
    • (2004) J Hypertens , vol.22 , pp. 1075-1079
    • Parati, G.1    Stergiou, G.2
  • 24
    • 2642514734 scopus 로고    scopus 로고
    • How many times should blood pressure be measured at home for better prediction of stroke risk? Ten-year follow-up results from the Ohasama study
    • Ohkubo T, Asayama K, Kikuya M, et al. How many times should blood pressure be measured at home for better prediction of stroke risk? Ten-year follow-up results from the Ohasama study. J Hypertens 2004; 22:1099-1104.
    • (2004) J Hypertens , vol.22 , pp. 1099-1104
    • Ohkubo, T.1    Asayama, K.2    Kikuya, M.3
  • 25
    • 0037257426 scopus 로고    scopus 로고
    • Tele-monitoring of home blood pressure in treated hypertensive patients
    • Møller DS, Madsen LD, Pedersen EB, et al. Tele-monitoring of home blood pressure in treated hypertensive patients. Blood Press 2003; 12:56-62.
    • (2003) Blood Press , vol.12 , pp. 56-62
    • Møller, D.S.1    Madsen, L.D.2    Pedersen, E.B.3
  • 26
    • 17044428618 scopus 로고    scopus 로고
    • Telemonitoring of blood pressure self measurement in the OLMTEL study
    • Mengden T, Ewald S, Kaufmann S, et al. Telemonitoring of blood pressure self measurement in the OLMTEL study. Blood Press Monit 2004; 9:321-325. Example of the use of telemonitoring to assess BP control.
    • (2004) Blood Press Monit , vol.9 , pp. 321-325
    • Mengden, T.1    Ewald, S.2    Kaufmann, S.3
  • 27
    • 17044377692 scopus 로고    scopus 로고
    • Telemonitoring of home blood pressure improves blood pressure control in hypertension
    • Parati G, Omboni S, Paintoni L, et al. Telemonitoring of home blood pressure improves blood pressure control in hypertension [abstract]. J Hypertens 2004; 22 (suppl 2):S137.
    • (2004) J Hypertens , vol.22 , Issue.SUPPL. 2
    • Parati, G.1    Omboni, S.2    Paintoni, L.3
  • 28
    • 0035811162 scopus 로고    scopus 로고
    • Home monitoring service improves mean arterial pressure in patients with essential hypertension
    • Rogers MAM, Small D, Buchan DA, et al. Home monitoring service improves mean arterial pressure in patients with essential hypertension. Ann Intern Med 2001; 134:1024-1032.
    • (2001) Ann Intern Med , vol.134 , pp. 1024-1032
    • Rogers, M.A.M.1    Small, D.2    Buchan, D.A.3
  • 29
    • 0032430927 scopus 로고    scopus 로고
    • Reliability of reporting self-measured blood pressure values by hypertensive patients
    • Mengden T, Hernandez Medina RM, Beltran B, et al. Reliability of reporting self-measured blood pressure values by hypertensive patients. Am J Hypertens 1998; 11:1413-1417.
    • (1998) Am J Hypertens , vol.11 , pp. 1413-1417
    • Mengden, T.1    Hernandez Medina, R.M.2    Beltran, B.3
  • 30
    • 0033799340 scopus 로고    scopus 로고
    • Comparison of self-reported home blood pressure measurements with automatically stored values and ambulatory blood pressure
    • Nordmann A, Frach B, Walker T, et al. Comparison of self-reported home blood pressure measurements with automatically stored values and ambulatory blood pressure. Blood Press 2001; 9:200-205.
    • (2001) Blood Press , vol.9 , pp. 200-205
    • Nordmann, A.1    Frach, B.2    Walker, T.3
  • 31
    • 0036863465 scopus 로고    scopus 로고
    • To what extent can we trust home blood pressure measurement? A randomized, controlled trial
    • Bachmann LM, Steurer J, Holm D, Vetter W. To what extent can we trust home blood pressure measurement? A randomized, controlled trial. J Clin Hypertens (Greenwich) 2002; 4:405-407; 412.
    • (2002) J Clin Hypertens (Greenwich) , vol.4 , pp. 405-407
    • Bachmann, L.M.1    Steurer, J.2    Holm, D.3    Vetter, W.4
  • 32
    • 0035200150 scopus 로고    scopus 로고
    • Reporting bias in self-measurement of blood pressure
    • Myers MG. Reporting bias in self-measurement of blood pressure. Blood Press Monit 2001; 6:181-183.
    • (2001) Blood Press Monit , vol.6 , pp. 181-183
    • Myers, M.G.1
  • 33
    • 0041589779 scopus 로고    scopus 로고
    • Accuracy of telemedical home blood pressure measurement in the diagnosis of hypertension
    • Møller DS. Dideriksen A, Sorensen S, et al. Accuracy of telemedical home blood pressure measurement in the diagnosis of hypertension. J Hum Hypertens 2003; 17:549-554.
    • (2003) J Hum Hypertens , vol.17 , pp. 549-554
    • Møller, D.S.1    Dideriksen, A.2    Sorensen, S.3
  • 34
    • 0036591587 scopus 로고    scopus 로고
    • Inter-arm differences in blood pressure: When are they clinically significant?
    • Lane D, Beevers M, Barnes N, et al. Inter-arm differences in blood pressure: when are they clinically significant? J Hypertens 2002; 20: 1089-1095.
    • (2002) J Hypertens , vol.20 , pp. 1089-1095
    • Lane, D.1    Beevers, M.2    Barnes, N.3
  • 35
    • 17144375670 scopus 로고    scopus 로고
    • Prognostic value of ambulatory and home blood pressure compared with office blood pressure in the general population
    • Sega R, Facchetti R, Bombelli M, et al. Prognostic value of ambulatory and home blood pressure compared with office blood pressure in the general population. Circulation 2005; 111:1777-1783. Two home BP measurements were made at entry on subjects from the general population enrolled in the PAMELA study. Office, home and ambulatory BP monitoring similarly predicted risk of cardiovascular and all-cause death but the risk of death increased more with a given increase in home or ambulatory BP than in office BP.
    • (2005) Circulation , vol.111 , pp. 1777-1783
    • Sega, R.1    Facchetti, R.2    Bombelli, M.3
  • 36
    • 4744364110 scopus 로고    scopus 로고
    • Prediction of stroke by self-measurement of blood pressure at home versus casual screening blood pressure measurement in relation to the Joint National Committee 7 classification
    • Asayama K, Ohkubo T, Kikuya M, et al. Prediction of stroke by self-measurement of blood pressure at home versus casual screening blood pressure measurement in relation to the Joint National Committee 7 classification. Stroke 2004; 35:2356-2361. Prospective cohort study showing that Joint National Committee 7 classification by home BP monitoring had a stronger predictive power than clinic BP for stroke or Transient Ischaemic Attack risk.
    • (2004) Stroke , vol.35 , pp. 2356-2361
    • Asayama, K.1    Ohkubo, T.2    Kikuya, M.3
  • 37
    • 20144389351 scopus 로고    scopus 로고
    • Prediction of ischaemic and haemorrhagic stroke by self-measured blood pressure at home: The Ohasama study
    • Ohkubo T, Asayama K, Kikuya M, et al. Prediction of ischaemic and haemorrhagic stroke by self-measured blood pressure at home: the Ohasama study. Blood Press Monit 2004; 9:315-320. First study to demonstrate that home BP is an independent predictor for haemorrhagic and ischaemic stroke in the general population.
    • (2004) Blood Press Monit , vol.9 , pp. 315-320
    • Ohkubo, T.1    Asayama, K.2    Kikuya, M.3
  • 39
    • 1642493775 scopus 로고    scopus 로고
    • White coat effect in treated versus untreated hypertensive individuals: A case control study using ambulatory and home blood pressure monitoring
    • Stergiou GS, Efstathiou SP, Argyraki CK, et al. White coat effect in treated versus untreated hypertensive individuals: a case control study using ambulatory and home blood pressure monitoring. Am J Hypertens 2004; 17:124-128. Case-controlled study showing that in treated hypertensive patients the white-coat effect is reduced compared to untreated hypertensive patients.
    • (2004) Am J Hypertens , vol.17 , pp. 124-128
    • Stergiou, G.S.1    Efstathiou, S.P.2    Argyraki, C.K.3
  • 40
    • 0038031722 scopus 로고    scopus 로고
    • Self-measured versus ambulatory blood pressure in the diagnosis of hypertension
    • Den Hond E, Celis H, Fagard R, et al., on behalf of the THOP investigators. Self-measured versus ambulatory blood pressure in the diagnosis of hypertension. J Hypertens 2003; 21:717-722.
    • (2003) J Hypertens , vol.21 , pp. 717-722
    • Den Hond, E.1    Celis, H.2    Fagard, R.3
  • 41
    • 17044386653 scopus 로고    scopus 로고
    • Antihypertensive treatment based on home or office blood pressure - The THOP trial
    • Den Hond E, Staessen JA, Celis H, et al. Antihypertensive treatment based on home or office blood pressure - the THOP trial. Blood Press Monit 2004; 9:311-314. Randomized trial comparing self-measured and office BP as a guide to drug initiation and titration.
    • (2004) Blood Press Monit , vol.9 , pp. 311-314
    • Den Hond, E.1    Staessen, J.A.2    Celis, H.3
  • 42
    • 19944398735 scopus 로고    scopus 로고
    • Control of blood pressure as measured at home and office, and comparison with physicians' assessment of control among treated hypertensive patients in Japan: First report of the Japan home versus office blood pressure measurement evaluation (J-Home) study
    • Ohkubo T, Obara T, Funahashi J, et al. Control of blood pressure as measured at home and office, and comparison with physicians' assessment of control among treated hypertensive patients in Japan: First report of the Japan home versus office blood pressure measurement evaluation (J-Home) study. Hypertens Res 2004; 27:755-763.
    • (2004) Hypertens Res , vol.27 , pp. 755-763
    • Ohkubo, T.1    Obara, T.2    Funahashi, J.3
  • 43
    • 11344262868 scopus 로고    scopus 로고
    • Improved blood pressure control with a physician-nurse team and home blood pressure measurement
    • Canzanello VJ, Jensen PL, Schwartz LL, et al. Improved blood pressure control with a physician-nurse team and home blood pressure measurement. Mayo Clin Proc 2005; 80:31-36. This study demonstrated the role of home BP monitoring in improving BP control in 106 patients with uncontrolled hypertension from 0 to 63%.
    • (2005) Mayo Clin Proc , vol.80 , pp. 31-36
    • Canzanello, V.J.1    Jensen, P.L.2    Schwartz, L.L.3
  • 44
    • 0029063986 scopus 로고
    • Prevalence of white coat effect in treated hypertensive patients in the community
    • Myers MG, Oh PI, Reeves RA, Joyner CD. Prevalence of white coat effect in treated hypertensive patients in the community. Am J Hypertens 1995; 8:591-597.
    • (1995) Am J Hypertens , vol.8 , pp. 591-597
    • Myers, M.G.1    Oh, P.I.2    Reeves, R.A.3    Joyner, C.D.4
  • 45
    • 1342326750 scopus 로고    scopus 로고
    • Diagnostic value of strategy for the detection of white coat hypertension based on ambulatory and home blood pressure monitoring
    • Stergiou GS, Almara CV, Skeva II, Mountokalakis TD. Diagnostic value of strategy for the detection of white coat hypertension based on ambulatory and home blood pressure monitoring. J Hum Hypertens 2004; 18:85-89. This study evaluates the role of home BP monitoring as a screening toot for white-coat hypertension and highlights that this strategy misses 39% of subjects.
    • (2004) J Hum Hypertens , vol.18 , pp. 85-89
    • Stergiou, G.S.1    Almara, C.V.2    Skeva, I.I.3    Mountokalakis, T.D.4
  • 46
    • 0026914087 scopus 로고
    • Home blood pressure monitoring. Effect on use of medical services and medical care costs
    • Soghikian K, Casper SM, Fireman BH, et al. Home blood pressure monitoring. Effect on use of medical services and medical care costs. Med Care 1992; 30:855-865.
    • (1992) Med Care , vol.30 , pp. 855-865
    • Soghikian, K.1    Casper, S.M.2    Fireman, B.H.3
  • 47
    • 1442359550 scopus 로고    scopus 로고
    • Antihypertensive treatment based on blood pressure measurement at home or in the physician's office
    • Staessen JA, Hond ED, Cells H, et al. Antihypertensive treatment based on blood pressure measurement at home or in the physician's office JAMA 2004; 291:955-964. Blinded, randomized controlled study which demonstrated that the use of home BP monitoring led to less intensive anti-hypertensive treatment and marginally lower costs. Also, home BP monitoring allowed identification of patients with white-coat hypertension.
    • (2004) JAMA , vol.291 , pp. 955-964
    • Staessen, J.A.1    Hond, E.D.2    Cells, H.3
  • 48
    • 3242727457 scopus 로고    scopus 로고
    • Blood pressure control by home monitoring: Meta-analysis of randomised trials
    • Cappuccio FP, Kerry SM, Forbes L, Donald A. Blood pressure control by home monitoring: meta-analysis of randomised trials. BMJ 2004; 329:145-148. Meta-analysis of 18 randomized controlled trials showing that self monitoring of BP at home results in better BP control (2.2/1.9 mmHg).
    • (2004) BMJ , vol.329 , pp. 145-148
    • Cappuccio, F.P.1    Kerry, S.M.2    Forbes, L.3    Donald, A.4
  • 49
    • 12644257594 scopus 로고    scopus 로고
    • Proposal of reference values for home blood pressure measurement: Prognostic criteria based on a prospective observation of the general population in Ohasama, Japan
    • Tsuji I, Imai Y, Nagai K, et al. Proposal of reference values for home blood pressure measurement: prognostic criteria based on a prospective observation of the general population in Ohasama, Japan. Am J Hypertens 1997; 10:409-418.
    • (1997) Am J Hypertens , vol.10 , pp. 409-418
    • Tsuji, I.1    Imai, Y.2    Nagai, K.3
  • 50
    • 4344670730 scopus 로고    scopus 로고
    • Home-based self-measurement of blood pressure: A proposal using new reference values (the PURAS study)
    • Divison JA, Sanchis C, Artigao LM, et al. Home-based self-measurement of blood pressure: a proposal using new reference values (the PURAS study). Blood Press Monit 2004; 9:211-218. Defines the home BP hypertension threshold as 131/82 mmHg and the limit of normality of 123/78 mmHg.
    • (2004) Blood Press Monit , vol.9 , pp. 211-218
    • Divison, J.A.1    Sanchis, C.2    Artigao, L.M.3
  • 51
    • 19944431172 scopus 로고    scopus 로고
    • The second progress report on the Hypertension Objective treatment based on Measurement by Electrical Devices of Blood Pressure (Home-BP Study Group)
    • Saito S, Asayama K, Ohkubo T. et al. The second progress report on the Hypertension Objective treatment based on Measurement by Electrical Devices of Blood Pressure (Home-BP Study Group). Blood Press Monit 2004; 9:243-247.
    • (2004) Blood Press Monit , vol.9 , pp. 243-247
    • Saito, S.1    Asayama, K.2    Ohkubo, T.3
  • 52
    • 0034892294 scopus 로고    scopus 로고
    • Management of hypertension in the elderly using home blood pressure
    • Broege PA, James GD, Pickenng TG. Management of hypertension in the elderly using home blood pressure. Blood Press Monit 2001; 6:139-144.
    • (2001) Blood Press Monit , vol.6 , pp. 139-144
    • Broege, P.A.1    James, G.D.2    Pickenng, T.G.3
  • 53
    • 0034896963 scopus 로고    scopus 로고
    • Assessment of biood pressure in patients with Type 2 diabetes: Comparison between home blood pressure monitoring, clinic blood pressure measurement and 24-h ambulatory blood pressure monitoring
    • Masding MG, Jones JR, Barley E, Sandeman DD. Assessment of biood pressure in patients with Type 2 diabetes: comparison between home blood pressure monitoring, clinic blood pressure measurement and 24-h ambulatory blood pressure monitoring. Diabetic Med 2001; 18:431-437.
    • (2001) Diabetic Med , vol.18 , pp. 431-437
    • Masding, M.G.1    Jones, J.R.2    Barley, E.3    Sandeman, D.D.4
  • 54
    • 11144272569 scopus 로고    scopus 로고
    • Undetected uncontrolled blood pressure in Type 2 diabetes: Self monitored blood pressure profiles
    • Mazze RS, Robinson R, Simonson G, et al. Undetected uncontrolled blood pressure in Type 2 diabetes: self monitored blood pressure profiles. Blood Press 2004; 13:335-342. Study of patients with diabetes and hypertension showing that home BP monitoring measured the dynamic daily fluctuations in BP, which results in patients with uncontrolled hypertension being undetected.
    • (2004) Blood Press , vol.13 , pp. 335-342
    • Mazze, R.S.1    Robinson, R.2    Simonson, G.3
  • 55
    • 1242297028 scopus 로고    scopus 로고
    • Home, clinic, and ambulatory blood pressure monitoring in children with chronic renal failure
    • Wuhl E, Hadstein C, Mehls O, Schaefer F. Home, clinic, and ambulatory blood pressure monitoring in children with chronic renal failure. Pediatr Res 2004; 55:492-497.
    • (2004) Pediatr Res , vol.55 , pp. 492-497
    • Wuhl, E.1    Hadstein, C.2    Mehls, O.3    Schaefer, F.4
  • 56
    • 20844435123 scopus 로고    scopus 로고
    • Reproducibility of home and ambulatory blood pressure in children and adolescents
    • Stergiou GS, Vaindirlis IN, Salgami EV, et al. Reproducibility of home and ambulatory blood pressure in children and adolescents. Blood Press Monit 2005; 10:143-147.
    • (2005) Blood Press Monit , vol.10 , pp. 143-147
    • Stergiou, G.S.1    Vaindirlis, I.N.2    Salgami, E.V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.