메뉴 건너뛰기




Volumn 43, Issue 14, 2004, Pages 2824-2832

Mueller polarimetric imaging system with liquid crystals

Author keywords

[No Author keywords available]

Indexed keywords

BIOPSY; CHARGE COUPLED DEVICES; COLLAGEN; LIGHT MODULATORS; LIGHT POLARIZATION; LIQUID CRYSTALS; OPTICAL DESIGN; PHOTOELASTICITY; POLARIMETERS; QUARTZ;

EID: 2542490228     PISSN: 1559128X     EISSN: 15394522     Source Type: Journal    
DOI: 10.1364/AO.43.002824     Document Type: Article
Times cited : (179)

References (19)
  • 1
    • 0017551521 scopus 로고
    • Photopolarimeter using two modulated optical rotators
    • R. M. A. Azzam, "Photopolarimeter using two modulated optical rotators," Opt. Lett. 2, 181-183 (1977).
    • (1977) Opt. Lett. , vol.2 , pp. 181-183
    • Azzam, R.M.A.1
  • 2
    • 85076671095 scopus 로고
    • High-resolution Mueller matrix imaging polarimetry for understanding high-resolution optoelectronic modulators
    • Photonics for Processors, Neural Networks, and Memories II, J. L. Horner, B. Javidi, and S. T. Kowel, eds.
    • J. L. Pezzaniti and R. A. Chipman, "High-resolution Mueller matrix imaging polarimetry for understanding high-resolution optoelectronic modulators," in Photonics for Processors, Neural Networks, and Memories II, J. L. Horner, B. Javidi, and S. T. Kowel, eds., Proc. SPIE 2297, 468-480 (1994).
    • (1994) Proc. SPIE , vol.2297 , pp. 468-480
    • Pezzaniti, J.L.1    Chipman, R.A.2
  • 3
    • 0032606398 scopus 로고    scopus 로고
    • Dual rotating-compensator multichannel ellipsometer: Instrument design for real-time Mueller matrix spectroscopy of surfaces and films
    • R. W. Collins and J. Kbh, "Dual rotating-compensator multichannel ellipsometer: instrument design for real-time Mueller matrix spectroscopy of surfaces and films," J. Opt. Soc. Am. A 16, 1997-2006 (1999).
    • (1999) J. Opt. Soc. Am. A , vol.16 , pp. 1997-2006
    • Collins, R.W.1    Kbh, J.2
  • 4
    • 0001517329 scopus 로고    scopus 로고
    • Automated high-speed Mueller matrix scatterometer
    • F. Delplancke, "Automated high-speed Mueller matrix scatterometer," Appl. Opt. 36, 5388-5395 (1997).
    • (1997) Appl. Opt. , vol.36 , pp. 5388-5395
    • Delplancke, F.1
  • 5
    • 36849101400 scopus 로고
    • An improved method for high reflectivity ellipsometry based on a new polarization modulation technique
    • S. N. Jasperson and S. E. Schnatterly, "An improved method for high reflectivity ellipsometry based on a new polarization modulation technique," Rev. Sci. Instrum. 40, 761-767 (1969).
    • (1969) Rev. Sci. Instrum. , vol.40 , pp. 761-767
    • Jasperson, S.N.1    Schnatterly, S.E.2
  • 6
    • 0000756250 scopus 로고    scopus 로고
    • High-frequency modulation of the four states of polarization of light with a single phase modulator
    • E. Compain and B. Drévillon, "High-frequency modulation of the four states of polarization of light with a single phase modulator," Rev. Sci. Instrum. 69, 1574-1580 (1998).
    • (1998) Rev. Sci. Instrum. , vol.69 , pp. 1574-1580
    • Compain, E.1    Drévillon, B.2
  • 7
    • 0033310313 scopus 로고    scopus 로고
    • Imaging spectropolarimeters for use in visible and infrared remote sensing
    • Imaging Spectrometry V, M. R. Descour and S. S. Shen, eds.
    • J. S. Tyo and T. S. Turner, Jr., "Imaging spectropolarimeters for use in visible and infrared remote sensing," in Imaging Spectrometry V, M. R. Descour and S. S. Shen, eds., Proc. SPIE 3753, 214-225 (1999).
    • (1999) Proc. SPIE , vol.3753 , pp. 214-225
    • Tyo, J.S.1    Turner Jr., T.S.2
  • 8
    • 0002810045 scopus 로고    scopus 로고
    • Double pass imaging polarimetry in the human eye
    • J. M. Bueno and P. Artal, "Double pass imaging polarimetry in the human eye," Opt. Lett. 24, 64-66 (1999).
    • (1999) Opt. Lett. , vol.24 , pp. 64-66
    • Bueno, J.M.1    Artal, P.2
  • 10
    • 0036629484 scopus 로고    scopus 로고
    • Development and calibration of an automated Mueller matrix polarization imaging system
    • J. S. Baba, J.-R. Chung, A. H. DeLaughter, B. D. Cameron, and G. L. Coté, "Development and calibration of an automated Mueller matrix polarization imaging system," J. Biomed. Opt. 7(3), 341-349 (2002).
    • (2002) J. Biomed. Opt. , vol.7 , Issue.3 , pp. 341-349
    • Baba, J.S.1    Chung, J.-R.2    Delaughter, A.H.3    Cameron, B.D.4    Coté, G.L.5
  • 11
    • 0001043980 scopus 로고    scopus 로고
    • Polarimetric images of a cone
    • P.-Y. Gerligand, M. H. Smith, and R. A. Chipman, "Polarimetric images of a cone," Opt. Express 4, 420-430 (1999), http://www. opticsexpress.org.
    • (1999) Opt. Express , vol.4 , pp. 420-430
    • Gerligand, P.-Y.1    Smith, M.H.2    Chipman, R.A.3
  • 13
    • 0003258382 scopus 로고    scopus 로고
    • Tissue optics: Light scattering methods and instruments for medical diagnosis
    • SPIE Press, Bellingham, Wash.
    • V. V. Tuchin, Tissue Optics: Light Scattering Methods and Instruments for Medical Diagnosis, Vol. TT38 of Tutorial Texts in Optical Engineering (SPIE Press, Bellingham, Wash., 2000).
    • (2000) Tutorial Texts in Optical Engineering , vol.TT38
    • Tuchin, V.V.1
  • 14
    • 5244244644 scopus 로고    scopus 로고
    • Interpretation of Mueller matrices based on polar decomposition
    • S.-Y. Lu and R. A. Chipman, "Interpretation of Mueller matrices based on polar decomposition," J. Opt. Soc. Am. A 13, 1106-1113 (1996).
    • (1996) J. Opt. Soc. Am. A , vol.13 , pp. 1106-1113
    • Lu, S.-Y.1    Chipman, R.A.2
  • 15
    • 0036478043 scopus 로고    scopus 로고
    • Design of optimal polarimeters: Maximization of signal-to-noise ratio and minimization of systematic errors
    • J. S. Tyo, "Design of optimal polarimeters: maximization of signal-to-noise ratio and minimization of systematic errors," Appl. Opt. 41, 619-630 (2002).
    • (2002) Appl. Opt. , vol.41 , pp. 619-630
    • Tyo, J.S.1
  • 17
    • 0000789341 scopus 로고    scopus 로고
    • General and self-consistent method for the calibration of polarization modulators, polarimeters, and Mueller-matrix ellipsometers
    • E. Compain, S. Poirier, and B. Drévillon, "General and self-consistent method for the calibration of polarization modulators, polarimeters, and Mueller-matrix ellipsometers," Appl. Opt. 38, 3490-3502 (1999).
    • (1999) Appl. Opt. , vol.38 , pp. 3490-3502
    • Compain, E.1    Poirier, S.2    Drévillon, B.3
  • 18
    • 0001988892 scopus 로고
    • Polarized light in biomedical research
    • P. Whittaker, "Polarized light in biomedical research," Microsc. Anal. 44, 15-17 (1995).
    • (1995) Microsc. Anal. , vol.44 , pp. 15-17
    • Whittaker, P.1
  • 19
    • 0000063297 scopus 로고    scopus 로고
    • Two-dimensional birefringence imaging in biological tissue by polarization-sensitive optical coherence tomography
    • J. F. de Boer, T. E. Milner, M. J. C. van Gemert, and J. S. Nelson, "Two-dimensional birefringence imaging in biological tissue by polarization-sensitive optical coherence tomography," Opt. Lett. 22, 934-936 (1997).
    • (1997) Opt. Lett. , vol.22 , pp. 934-936
    • De Boer, J.F.1    Milner, T.E.2    Van Gemert, M.J.C.3    Nelson, J.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.