메뉴 건너뛰기




Volumn 14, Issue 3, 2005, Pages 393-399

Predicting ATS open pivot™ heart valve performance with computational fluid dynamics

Author keywords

[No Author keywords available]

Indexed keywords

AORTA FLOW; ARTICLE; COMPUTATIONAL FLUID DYNAMICS; GEOMETRY; HEART PERFORMANCE; HEART VALVE; HEMODYNAMICS; IN VITRO STUDY; PRIORITY JOURNAL; SHEAR STRESS; AORTA VALVE; BIOLOGICAL MODEL; BIOMECHANICS; BLOOD FLOW VELOCITY; BLOOD VISCOSITY; COMPUTER SIMULATION; FLOW KINETICS; FORECASTING; HEART VALVE PROSTHESIS; HEART VENTRICLE PRESSURE; HUMAN; MATERIALS TESTING; MECHANICAL STRESS; MITRAL VALVE; PHYSIOLOGY; PROSTHESIS; SURFACE PROPERTY; THREE DIMENSIONAL IMAGING;

EID: 24344466936     PISSN: 09668519     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (25)

References (27)
  • 2
    • 0035985025 scopus 로고    scopus 로고
    • Computational fluid dynamics insights in the design of mechanical heart valves
    • Kelly SGD. Computational fluid dynamics insights in the design of mechanical heart valves. Artif Organs 2002;26:608-613
    • (2002) Artif Organs , vol.26 , pp. 608-613
    • Kelly, S.G.D.1
  • 3
    • 0029047248 scopus 로고
    • Numerical simulation of instantaneous backflow through central clearance of bi-leaflet mechanical heart valve at closure: Shear stresses and pressure fields
    • Lee CS, Chandran KB. Numerical simulation of instantaneous backflow through central clearance of bi-leaflet mechanical heart valve at closure: Shear stresses and pressure fields. Med Biol Eng Comput 1995;33:257-263
    • (1995) Med Biol Eng Comput , vol.33 , pp. 257-263
    • Lee, C.S.1    Chandran, K.B.2
  • 5
    • 0031543374 scopus 로고    scopus 로고
    • Pulse duplicator hydrodynamics of four different bileaflet valves in the mitral position
    • Verdonck PR, Van Nooten GJ, Van Belleghem Y. Pulse duplicator hydrodynamics of four different bileaflet valves in the mitral position. Cardiovasc Surg 1997;5:593-603
    • (1997) Cardiovasc Surg , vol.5 , pp. 593-603
    • Verdonck, P.R.1    Van Nooten, G.J.2    Van Belleghem, Y.3
  • 6
    • 0034048214 scopus 로고    scopus 로고
    • In vitro hydrodynamic characteristics among three bileaflet valves in the mitral position
    • Feng Z, Umezu M, Fujimoto T, Tsukahara T, Nurishi M, Kawaguchi D. In vitro hydrodynamic characteristics among three bileaflet valves in the mitral position. Artif Organs 2000;24:346-354
    • (2000) Artif Organs , vol.24 , pp. 346-354
    • Feng, Z.1    Umezu, M.2    Fujimoto, T.3    Tsukahara, T.4    Nurishi, M.5    Kawaguchi, D.6
  • 7
    • 0036118796 scopus 로고    scopus 로고
    • In vitro investigation of opening behavior and hydrodynamics of bileaflet valves in the mitral position
    • Feng Z, Nakamura T, Fujimoto T, Umezu M. In vitro investigation of opening behavior and hydrodynamics of bileaflet valves in the mitral position. Artif Organs 2002;26:32-39
    • (2002) Artif Organs , vol.26 , pp. 32-39
    • Feng, Z.1    Nakamura, T.2    Fujimoto, T.3    Umezu, M.4
  • 8
    • 0036270087 scopus 로고    scopus 로고
    • A numerical simulation of mechanical heart valve closure fluid dynamics
    • Lai YG, Chandran KB, Lemmon J. A numerical simulation of mechanical heart valve closure fluid dynamics. J Biomech 2002;35:881-892
    • (2002) J Biomech , vol.35 , pp. 881-892
    • Lai, Y.G.1    Chandran, K.B.2    Lemmon, J.3
  • 9
    • 0344034637 scopus 로고    scopus 로고
    • Two-dimensional fluid-structure interaction simulation of bileaflet mechanical heart valve flow dynamics
    • Cheng R, Lai YG, Chandran KB. Two-dimensional fluid-structure interaction simulation of bileaflet mechanical heart valve flow dynamics. J Heart Valve Dis 2003;12:772-780
    • (2003) J Heart Valve Dis , vol.12 , pp. 772-780
    • Cheng, R.1    Lai, Y.G.2    Chandran, K.B.3
  • 10
    • 85085779585 scopus 로고    scopus 로고
    • Vierendeels J, Dumont K, Verdonck PR. Stabilization of a fluid-structure coupling procedure for rigid body motion. 33rd AIAA Fluid Dynamics Conference and Exhibit 2003; pages AIAA-2003-3720, 23-26 June 2003, Orlando, US
    • Vierendeels J, Dumont K, Verdonck PR. Stabilization of a fluid-structure coupling procedure for rigid body motion. 33rd AIAA Fluid Dynamics Conference and Exhibit 2003; pages AIAA-2003-3720, 23-26 June 2003, Orlando, US
  • 12
    • 85025757493 scopus 로고
    • Modeling prosthetic heart-valves for numerical-analysis of blood-flow in the heart
    • Peskin CS and McQueen DM. Modeling prosthetic heart-valves for numerical-analysis of blood-flow in the heart. J Comput Phys 1980; 37:113-132
    • (1980) J Comput Phys , vol.37 , pp. 113-132
    • Peskin, C.S.1    McQueen, D.M.2
  • 13
    • 0942291108 scopus 로고    scopus 로고
    • Finite-element-based computational methods for cardiovascular fluid-structure interaction
    • van de Vosse F, de Hart J, van Oijen C, et al. Finite-element-based computational methods for cardiovascular fluid-structure interaction. J Eng Math 2003; 47:335-368
    • (2003) J Eng Math , vol.47 , pp. 335-368
    • van de Vosse, F.1    de Hart, J.2    van Oijen, C.3
  • 14
    • 31744438204 scopus 로고
    • Arbitrary Lagrangian-Eulerian method for transient fluid-structure interactions
    • Chu H. Arbitrary Lagrangian-Eulerian method for transient fluid-structure interactions. Nucl Technol 1980;51:363-377
    • (1980) Nucl Technol , vol.51 , pp. 363-377
    • Chu, H.1
  • 15
    • 0032556586 scopus 로고    scopus 로고
    • A monolithical fluid-structure interaction algorithm applied to the piston problem
    • Blom F. A monolithical fluid-structure interaction algorithm applied to the piston problem. Computer Methods Appl Mech Eng 1998;167:369-391
    • (1998) Computer Methods Appl Mech Eng , vol.167 , pp. 369-391
    • Blom, F.1
  • 16
    • 0000746174 scopus 로고    scopus 로고
    • Direct and iterative computing of fluid flows fully coupled with structures
    • Bathe KJ ed, Elsevier, Amsterdam
    • Zhang H, Bathe K. Direct and iterative computing of fluid flows fully coupled with structures. In: Bathe KJ (ed.), Computational Fluid and Solid Mechanics. Elsevier, Amsterdam, 2001
    • (2001) Computational Fluid and Solid Mechanics
    • Zhang, H.1    Bathe, K.2
  • 17
    • 0029310928 scopus 로고
    • Partitioned procedures for the transient solution of coupled aeroelastic problems: Model problem, theory and 2-dimensional application
    • Piperno S, Farhat C, Larrouturou B. Partitioned procedures for the transient solution of coupled aeroelastic problems: Model problem, theory and 2-dimensional application. Computer Methods Appl Mech Eng 1995;124:79-112
    • (1995) Computer Methods Appl Mech Eng , vol.124 , pp. 79-112
    • Piperno, S.1    Farhat, C.2    Larrouturou, B.3
  • 19
    • 0030916347 scopus 로고    scopus 로고
    • Cineradiographic evaluation of ATS open pivot bileaflet valves
    • Aoyagi S, Kawara T, Fukunaga S, et al. Cineradiographic evaluation of ATS open pivot bileaflet valves. J Heart Valve Dis 1997;6:258-263
    • (1997) J Heart Valve Dis , vol.6 , pp. 258-263
    • Aoyagi, S.1    Kawara, T.2    Fukunaga, S.3
  • 20
    • 0030499275 scopus 로고    scopus 로고
    • Doppler echocardiographic assessment of the new ATS medical prosthetic valve in the aortic position
    • Karpuz H, Jeanrenaud X, Hurni M, et al. Doppler echocardiographic assessment of the new ATS medical prosthetic valve in the aortic position. Am J Cardiovasc Imaging 1996;10:254-260
    • (1996) Am J Cardiovasc Imaging , vol.10 , pp. 254-260
    • Karpuz, H.1    Jeanrenaud, X.2    Hurni, M.3
  • 21
    • 0037312447 scopus 로고    scopus 로고
    • The initial experience with the ATS medical mechanical cardiac valve prosthesis
    • Emery RW, Van Nooten GJ, Tesar PJ. The initial experience with the ATS medical mechanical cardiac valve prosthesis. Ann Thorac Surg 2003;75:444-452
    • (2003) Ann Thorac Surg , vol.75 , pp. 444-452
    • Emery, R.W.1    Van Nooten, G.J.2    Tesar, P.J.3
  • 23
    • 2542439910 scopus 로고    scopus 로고
    • Numerical estimation of blood damage in artificial organs
    • Goubergrits L, Affeld K. Numerical estimation of blood damage in artificial organs. Int J Artif Organs 2004;28:499-507
    • (2004) Int J Artif Organs , vol.28 , pp. 499-507
    • Goubergrits, L.1    Affeld, K.2
  • 24
    • 2542462454 scopus 로고    scopus 로고
    • The power-law mathematical model for blood damage prediction: Analytical developments and physical inconsistencies
    • Grigioni M, Daniele C, Morbiducci U, D'Avenio G. The power-law mathematical model for blood damage prediction: Analytical developments and physical inconsistencies. Int J Artif Organs 2004;28:467-475
    • (2004) Int J Artif Organs , vol.28 , pp. 467-475
    • Grigioni, M.1    Daniele, C.2    Morbiducci, U.3    D'Avenio, G.4
  • 25
    • 0030019453 scopus 로고    scopus 로고
    • Pressure gradients across bileaflet aortic valves by direct measurement and echocardiography
    • Laske A, Jenni R, Maloigne M, Vassalli G, Bertel O, Turina MI. Pressure gradients across bileaflet aortic valves by direct measurement and echocardiography. Ann Thorac Surg 1996;61:48-57
    • (1996) Ann Thorac Surg , vol.61 , pp. 48-57
    • Laske, A.1    Jenni, R.2    Maloigne, M.3    Vassalli, G.4    Bertel, O.5    Turina, M.I.6
  • 26
    • 0036889713 scopus 로고    scopus 로고
    • Free emboli formation in the wake of bi-leaflet mechanical heart valves and the effects of implantation techniques
    • Bluestein D, Li YM, Krukenkamp IB. Free emboli formation in the wake of bi-leaflet mechanical heart valves and the effects of implantation techniques. J Biomech 2002;35:1533-1540
    • (2002) J Biomech , vol.35 , pp. 1533-1540
    • Bluestein, D.1    Li, Y.M.2    Krukenkamp, I.B.3
  • 27
    • 34447337015 scopus 로고    scopus 로고
    • ATS Medical Inc., Pre-Market Approval Application - Summary of Safety and Effectiveness: 200. Washington DC, US Food and Drug Administration, 2000. P990046.
    • ATS Medical Inc., Pre-Market Approval Application - Summary of Safety and Effectiveness: 200. Washington DC, US Food and Drug Administration, 2000. P990046.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.