메뉴 건너뛰기




Volumn 15, Issue 9, 2005, Pages 1915-1922

Two-dimensional and three-dimensional oxygen mapping by 3He-MRI validation in a lung phantom

Author keywords

3He magnetic resonance imaging; Lung; Oxygen; Validation

Indexed keywords

HELIUM; OXYGEN; SILICON;

EID: 24044432254     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-005-2778-x     Document Type: Article
Times cited : (7)

References (31)
  • 6
    • 0035984154 scopus 로고    scopus 로고
    • Zusammenhang zwischen Empyhsemtyp und Schweregrad der Pneumokoniose bei Bergleuten: Korrelation von HR-CT-Befunden und ILO-Klassifikation
    • Eibel R, Weber A, Stolpe S, Hellenbrand U, Bauer T (2002) Zusammenhang zwischen Empyhsemtyp und Schweregrad der Pneumokoniose bei Bergleuten: Korrelation von HR-CT-Befunden und ILO-Klassifikation [Correlation of different types of emphysema in high-resolution computed tomography (HR-CT) with the ILO-classification of coal workers pneumoconiosis]. Fortschr Röntgenstr 174:846-853
    • (2002) Fortschr Röntgenstr , vol.174 , pp. 846-853
    • Eibel, R.1    Weber, A.2    Stolpe, S.3    Hellenbrand, U.4    Bauer, T.5
  • 12
    • 2042450177 scopus 로고    scopus 로고
    • 3He-MRI
    • Habilitation Thesis, Department of Anesthesiology. Johannes Gutenberg-University: Mainz, Germany
    • 3He-MRI., in Habilitation Thesis, Department of Anesthesiology. Johannes Gutenberg-University: Mainz, Germany
    • (2000)
    • Eberle, B.1
  • 19
    • 0028839871 scopus 로고
    • The Rician distribution of noisy MRI data
    • Erratum in: Magn Reson Med 1996 Aug;36(2):332
    • Gudbjartsson H, Patz S (1995) The Rician distribution of noisy MRI data. Magn Reson Med 34(6):910-914. Erratum in: Magn Reson Med 1996 Aug;36(2):332
    • (1995) Magn. Reson. Med. , vol.34 , Issue.6 , pp. 910-914
    • Gudbjartsson, H.1    Patz, S.2
  • 21
    • 6044221075 scopus 로고    scopus 로고
    • Ein Auswerteprogramm zur quantitativen Analyse von Messungen des alveolären Sauerstoffpartialdrucks (pAO2) mit der sauerstoffsensitiven 3He-MR-Tomographie
    • Lehmann F, Eberle B, Markstaller K, Gast KK, Schmiedeskamp J, Blümler P, Kauczor HU, Schreiber WG (2004) Ein Auswerteprogramm zur quantitativen Analyse von Messungen des alveolären Sauerstoffpartialdrucks (pAO2) mit der sauerstoffsensitiven 3He-MR-Tomographie [A Software Program for Quantitative Analysis of Alveolar Oxygen Partial Pressure (pAO2) with Oxygen-sensitive 3He-MRI]. Fortschr Röntgenstr 176(10):1390-1398
    • (2004) Fortschr Röntgenstr , vol.176 , Issue.10 , pp. 1390-1398
    • Lehmann, F.1    Eberle, B.2    Markstaller, K.3    Gast, K.K.4    Schmiedeskamp, J.5    Blümler, P.6    Kauczor, H.U.7    Schreiber, W.G.8
  • 22
    • 6044258858 scopus 로고    scopus 로고
    • Quantitative Untersuchung der Lungenventilation mittels dynamischer MRT von hochpolarisiertem Helium-3
    • Lehmann F, Knitz F, Weiler N, Gast KK, Ley S, Schmiedeskamp J, Bellemann ME, Kauczor HU, WG Schreider (2004) Quantitative Untersuchung der Lungenventilation mittels dynamischer MRT von hochpolarisiertem Helium-3 [A Software Tool for Analysis and Quantification of Regional Pulmonary Ventilation Using Dynamic Hyperpolarised-3He-MRI]. Fortschr Röntgenstr 176(10):1399-1408
    • (2004) Fortschr Röntgenstr , vol.176 , Issue.10 , pp. 1399-1408
    • Lehmann, F.1    Knitz, F.2    Weiler, N.3    Gast, K.K.4    Ley, S.5    Schmiedeskamp, J.6    Bellemann, M.E.7    Kauczor, H.U.8    Schreider, W.G.9
  • 26
    • 0038417022 scopus 로고    scopus 로고
    • Operating characteristics of hyperpolarized 3He and arterial spin tagging in MR imaging of ventilation and perfusion in healthy subjects
    • Rizi RR, Lipson DA, Dimitrov IE, Ishii M, Roberts DA (2003) Operating characteristics of hyperpolarized 3He and arterial spin tagging in MR imaging of ventilation and perfusion in healthy subjects. Acad Radiol 10(5):502-508
    • (2003) Acad. Radiol. , vol.10 , Issue.5 , pp. 502-508
    • Rizi, R.R.1    Lipson, D.A.2    Dimitrov, I.E.3    Ishii, M.4    Roberts, D.A.5
  • 31
    • 0034789556 scopus 로고    scopus 로고
    • Dynamic spiral MRI of pulmonary gas flow using hyperpolarized 3 He: Preliminary studies in healthy and diseased lungs
    • Salerno M, Altes TA, Brookeman JR, De Lange EE, Mugler JP III (2001) Dynamic spiral MRI of pulmonary gas flow using hyperpolarized 3 He: preliminary studies in healthy and diseased lungs. Magn Reson Med 46:667-677
    • (2001) Magn. Reson. Med. , vol.46 , pp. 667-677
    • Salerno, M.1    Altes, T.A.2    Brookeman, J.R.3    De Lange, E.E.4    Mugler III, J.P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.