메뉴 건너뛰기




Volumn 26, Issue 2, 2005, Pages

Automatic detection of detached and erroneous electrodes in electrical impedance tomography

Author keywords

Data errors; Electrical impedance tomography; Electrodes; Image reconstruction

Indexed keywords

ELECTRIC IMPEDANCE; ELECTRIC IMPEDANCE MEASUREMENT; ELECTRIC IMPEDANCE TOMOGRAPHY; ELECTRODES;

EID: 23044465777     PISSN: 09673334     EISSN: 09673334     Source Type: Journal    
DOI: 10.1088/0967-3334/26/2/017     Document Type: Conference Paper
Times cited : (29)

References (9)
  • 1
    • 1342268923 scopus 로고    scopus 로고
    • Accounting for erroneous electrode data in electrical impedance tomography
    • Adler A 2004 Accounting for erroneous electrode data in electrical impedance tomography Physiol. Meas. 25 227-38
    • (2004) Physiol. Meas. , vol.25 , pp. 227-238
    • Adler, A.1
  • 2
    • 0030657934 scopus 로고    scopus 로고
    • Monitoring changes in lung air and liquid volumes with electrical impedance tomography
    • Adler A, Amyot R, Guardo R, Bates J H T and Berthiaume Y 1997 Monitoring changes in lung air and liquid volumes with electrical impedance tomography J. Appl. Physiol. 83 1762-7
    • (1997) J. Appl. Physiol. , vol.83 , pp. 1762-1767
    • Adler, A.1    Amyot, R.2    Guardo, R.3    Bates, J.H.T.4    Berthiaume, Y.5
  • 3
    • 0030126713 scopus 로고    scopus 로고
    • Electrical impedance tomography: Regularised imaging and contrast detection
    • Adler A and Guardo R 1996 Electrical impedance tomography: regularised imaging and contrast detection IEEE Trans. Med. Imaging 15 170-9
    • (1996) IEEE Trans. Med. Imaging , vol.15 , pp. 170-179
    • Adler, A.1    Guardo, R.2
  • 4
    • 0031834864 scopus 로고    scopus 로고
    • Patient-instrument connection errors in bioelectrical impedance measurement
    • Al-Hatib F 1998 Patient-instrument connection errors in bioelectrical impedance measurement Physiol. Meas. 19 285-96
    • (1998) Physiol. Meas. , vol.19 , pp. 285-296
    • Al-Hatib, F.1
  • 5
    • 0031863430 scopus 로고    scopus 로고
    • Electrical impedance tomography with compensation for electrode positioning variations
    • Blott B H, Daniell G J and Meeson S 1998 Electrical impedance tomography with compensation for electrode positioning variations Phys. Med. Biol. 43 1731-9
    • (1998) Phys. Med. Biol. , vol.43 , pp. 1731-1739
    • Blott, B.H.1    Daniell, G.J.2    Meeson, S.3
  • 6
    • 0029849438 scopus 로고    scopus 로고
    • An interleaved drive electrical impedance tomography image reconstruction algorithm
    • Eyüboǧlu B M 1996 An interleaved drive electrical impedance tomography image reconstruction algorithm Physiol. Meas. 17 A59-71
    • (1996) Physiol. Meas. , vol.17
    • Eyüboǧlu, B.M.1
  • 8
    • 0028998912 scopus 로고
    • Errors in prolonged electrical impedance measurements due to electrode repositioning and postural changes
    • Lozano A, Rosell J and Pallás-Areny R 1995 Errors in prolonged electrical impedance measurements due to electrode repositioning and postural changes Physiol. Meas. 16 121-30
    • (1995) Physiol. Meas. , vol.16 , pp. 121-130
    • Lozano, A.1    Rosell, J.2    Pallás-Areny, R.3
  • 9
    • 0029807203 scopus 로고    scopus 로고
    • EIT data noise evaluation in the clinical environment
    • Meeson S, Blott B and Killingback A 1996 EIT data noise evaluation in the clinical environment Physiol. Meas. 17 (Suppl.) A33-A38
    • (1996) Physiol. Meas. , vol.17 , Issue.SUPPL.
    • Meeson, S.1    Blott, B.2    Killingback, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.