-
1
-
-
0021747492
-
Strength of polymethylmethacrylate increased by vacuum mixing
-
L. Lidgren, H. Drar, and J. Möller Strength of polymethylmethacrylate increased by vacuum mixing Acta Orthop. Scand. 55 1984 536 541
-
(1984)
Acta Orthop. Scand.
, vol.55
, pp. 536-541
-
-
Lidgren, L.1
Drar, H.2
Möller, J.3
-
2
-
-
0024463598
-
Air inclusion in bone cement. Importance of mixing technique
-
U. Linden, and J. Gillquist Air inclusion in bone cement. Importance of mixing technique Clin. Orthop. 247 1989 148 151
-
(1989)
Clin. Orthop.
, vol.247
, pp. 148-151
-
-
Linden, U.1
Gillquist, J.2
-
3
-
-
0025427714
-
Effect of vacuum mixing on the mechanical properties of antibiotic-impregnated polymethylmethacrylate bone cement
-
M.J. Askew, M.F. Kufel, P.R. Flessner Jr., I.A. Gradisar Jr., S.J. Salstrom, and J.S. Tan Effect of vacuum mixing on the mechanical properties of antibiotic-impregnated polymethylmethacrylate bone cement J. Biomed. Mater. Res. 24 1990 573 580
-
(1990)
J. Biomed. Mater. Res.
, vol.24
, pp. 573-580
-
-
Askew, M.J.1
Kufel, M.F.2
Flessner Jr., P.R.3
Gradisar Jr., I.A.4
Salstrom, S.J.5
Tan, J.S.6
-
4
-
-
0031238588
-
Effect of mixing on selected properties of acrylic bone cement
-
G. Lewis, J.S. Nyman, and H.H. Trieu Effect of mixing on selected properties of acrylic bone cement J. Biomed. Mater. Res. 38 1997 221 228
-
(1997)
J. Biomed. Mater. Res.
, vol.38
, pp. 221-228
-
-
Lewis, G.1
Nyman, J.S.2
Trieu, H.H.3
-
5
-
-
0346970726
-
The effect of mixing on gentamicin release from polymethylmethacrylate bone cement
-
D. Neut, H. van de Belt, J.R. van Horn, H. van der Mei, and H.J. Busscher The effect of mixing on gentamicin release from polymethylmethacrylate bone cement Acta Orthop. Scand. 74 2003 670 676
-
(2003)
Acta Orthop. Scand.
, vol.74
, pp. 670-676
-
-
Neut, D.1
Van De Belt, H.2
Van Horn, J.R.3
Van Der Mei, H.4
Busscher, H.J.5
-
6
-
-
0033861254
-
Long-term registration has improved the quality of hip replacement: A review of the Swedish THR Register comparing 160,000 cases
-
P. Herberts, and H. Malchau Long-term registration has improved the quality of hip replacement: a review of the Swedish THR Register comparing 160,000 cases Acta Orthop. Scand. 71 2000 111 121
-
(2000)
Acta Orthop. Scand.
, vol.71
, pp. 111-121
-
-
Herberts, P.1
Malchau, H.2
-
7
-
-
0036678147
-
The type of cement and failure of total hip replacements
-
B. Espehaug, O. Furnes, L.I. Havelin, L.B. Engesaeter, and S.E. Vollset The type of cement and failure of total hip replacements J. Bone Joint Surg. Br. 84B 2002 832 838
-
(2002)
J. Bone Joint Surg. Br.
, vol.84
, pp. 832-838
-
-
Espehaug, B.1
Furnes, O.2
Havelin, L.I.3
Engesaeter, L.B.4
Vollset, S.E.5
-
8
-
-
0025614369
-
Prechilling and vacuum mixing not suitable for all bone cements. Handling characteristics and exotherms of bone cements
-
D. Hansen, and J.S. Jensen Prechilling and vacuum mixing not suitable for all bone cements. Handling characteristics and exotherms of bone cements J. Arthroplasty 5 1990 287 290
-
(1990)
J. Arthroplasty
, vol.5
, pp. 287-290
-
-
Hansen, D.1
Jensen, J.S.2
-
9
-
-
0031013653
-
Influence of temperature and vacuum mixing on bone cement properties
-
S. Smeds, D. Goertzen, and I. Ivarsson Influence of temperature and vacuum mixing on bone cement properties Clin. Orthop. 334 1997 326 334
-
(1997)
Clin. Orthop.
, vol.334
, pp. 326-334
-
-
Smeds, S.1
Goertzen, D.2
Ivarsson, I.3
-
10
-
-
0028802391
-
The effect of the type of cement on early revision of Charnley total hip prostheses. a review of eight thousand five hundred and seventy-nine primary arthroplasties from the Norwegian Arthroplasty Register
-
L.I. Havelin, B. Espehaug, S.E. Vollset, and L.B. Engesaeter The effect of the type of cement on early revision of Charnley total hip prostheses. A review of eight thousand five hundred and seventy-nine primary arthroplasties from the Norwegian Arthroplasty Register J. Bone Joint Surg. Am 77A 1995 1543 1550
-
(1995)
J. Bone Joint Surg. Am
, vol.77
, pp. 1543-1550
-
-
Havelin, L.I.1
Espehaug, B.2
Vollset, S.E.3
Engesaeter, L.B.4
-
11
-
-
0028989433
-
Boneloc-the Christiansen experience revisited
-
L. Linder Boneloc-the Christiansen experience revisited Acta Orthop. Scand. 66 1995 205 206
-
(1995)
Acta Orthop. Scand.
, vol.66
, pp. 205-206
-
-
Linder, L.1
-
13
-
-
0028914203
-
Early failure with Boneloc bone cement. 4/8 Femoral stems loose within 3 years
-
S. Suominen Early failure with Boneloc bone cement. 4/8 Femoral stems loose within 3 years Acta Orthop. Scand. 66 1995 13
-
(1995)
Acta Orthop. Scand.
, vol.66
, pp. 13
-
-
Suominen, S.1
-
14
-
-
0028989434
-
Evaluation of Boneloc. Chemical and mechanical properties, and a randomized clinical study of 30 total hip arthroplasties
-
J. Thanner, C. Freij-Larsson, J. Kärrholm, H. Malchau, and B. Wesslen Evaluation of Boneloc. Chemical and mechanical properties, and a randomized clinical study of 30 total hip arthroplasties Acta Orthop. Scand. 66 1995 207 214
-
(1995)
Acta Orthop. Scand.
, vol.66
, pp. 207-214
-
-
Thanner, J.1
Freij-Larsson, C.2
Kärrholm, J.3
Malchau, H.4
Wesslen, B.5
-
15
-
-
0030042735
-
Total hip arthroplasty with Boneloc: Loosening in 102/157 cases after 0.5-3 years
-
A.R. Nilsen, and M. Wiig Total hip arthroplasty with Boneloc: loosening in 102/157 cases after 0.5-3 years Acta Orthop. Scand. 67 1996 57 59
-
(1996)
Acta Orthop. Scand.
, vol.67
, pp. 57-59
-
-
Nilsen, A.R.1
Wiig, M.2
-
16
-
-
0031757919
-
Inferior performance of Boneloc bone cement in total knee arthroplasty: A prospective randomized study comparing Boneloc with Palacos using radiostereometry (RSA) in 19 patients
-
K.G. Nilsson, and T. Dalén Inferior performance of Boneloc bone cement in total knee arthroplasty: a prospective randomized study comparing Boneloc with Palacos using radiostereometry (RSA) in 19 patients Acta Orthop. Scand. 69 1998 479 483
-
(1998)
Acta Orthop. Scand.
, vol.69
, pp. 479-483
-
-
Nilsson, K.G.1
Dalén, T.2
-
19
-
-
0002357815
-
Osteoarthrosis of the knee: A radiographic investigation
-
S. Ahlbäck Osteoarthrosis of the knee: a radiographic investigation Acta Radiol. Suppl. 277 1968 1 25
-
(1968)
Acta Radiol.
, Issue.SUPPL. 277
, pp. 1-25
-
-
Ahlbäck, S.1
-
21
-
-
0024388994
-
Roentgen stereophotogrammetry. a method for the study of the kinematics of the skeletal system
-
Thesis, University of Lund, Sweden, 1974. Reprint in:
-
G. Selvik, Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system. Thesis, University of Lund, Sweden, 1974. Reprint in: Acta Orthop. Scand. 1989; (Suppl. 232): 1-38.
-
(1989)
Acta Orthop. Scand.
, Issue.232 SUPPL.
, pp. 1-38
-
-
Selvik, G.1
-
22
-
-
0027375369
-
Increased varus-valgus tilting of screw-fixated knee prostheses. Stereoradiographic study of uncemented versus cemented tibial components
-
K.G. Nilsson, and J. Kärrholm Increased varus-valgus tilting of screw-fixated knee prostheses. Stereoradiographic study of uncemented versus cemented tibial components J. Arthroplasty 5 1993 529 540
-
(1993)
J. Arthroplasty
, vol.5
, pp. 529-540
-
-
Nilsson, K.G.1
Kärrholm, J.2
-
23
-
-
0029062186
-
Femoral component migration in total knee arthroplasty: Randomized study comparing cemented and uncemented fixation of the Miller-Galante I design
-
K.G. Nilsson, J. Kärrholm, and L. Linder Femoral component migration in total knee arthroplasty: randomized study comparing cemented and uncemented fixation of the Miller-Galante I design J. Orthop. Res. 13 1995 347 356
-
(1995)
J. Orthop. Res.
, vol.13
, pp. 347-356
-
-
Nilsson, K.G.1
Kärrholm, J.2
Linder, L.3
-
24
-
-
0025986872
-
Evaluation of micromotion in cemented vs. uncemented knee arthroplasty in osteoarthrosis and rheumatoid arthritis. Randomized study using roentgen stereophotogrammetric analysis
-
K.G. Nilsson, J. Kärrholm, L. Ekelund, and P. Magnusson Evaluation of micromotion in cemented vs. uncemented knee arthroplasty in osteoarthrosis and rheumatoid arthritis. Randomized study using roentgen stereophotogrammetric analysis J. Arthroplasty 6 1991 265 278
-
(1991)
J. Arthroplasty
, vol.6
, pp. 265-278
-
-
Nilsson, K.G.1
Kärrholm, J.2
Ekelund, L.3
Magnusson, P.4
-
25
-
-
0022542239
-
Micromotion in knee arthroplasty: A roentgen stereophotogrammetric analysis of tibial component fixation
-
L. Ryd Micromotion in knee arthroplasty: a roentgen stereophotogrammetric analysis of tibial component fixation Acta Orthop. Scand. 57 Suppl. 220 1986 1 60
-
(1986)
Acta Orthop. Scand.
, vol.57
, Issue.SUPPL. 220
, pp. 1-60
-
-
Ryd, L.1
-
26
-
-
0029056371
-
Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses
-
L. Ryd, B.E.J. Albrektsson, L. Carlsson, F. Dansgård, P. Herberts, and A. Lindstrand Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses J. Bone Joint Surg. Br. 77B 1995 377 383
-
(1995)
J. Bone Joint Surg. Br.
, vol.77
, pp. 377-383
-
-
Ryd, L.1
Albrektsson, B.E.J.2
Carlsson, L.3
Dansgård, F.4
Herberts, P.5
Lindstrand, A.6
-
27
-
-
0032922332
-
Hydroxyapatite coating versus cemented fixation of the tibial component in total knee arthroplasty: Prospective randomized comparison of hydroxyapatite-coated and cemented tibial components with 5-year follow-up using radiostereometry
-
K.G. Nilsson, J. Kärrholm, L. Carlsson, and T. Dalen Hydroxyapatite coating versus cemented fixation of the tibial component in total knee arthroplasty: prospective randomized comparison of hydroxyapatite-coated and cemented tibial components with 5-year follow-up using radiostereometry J. Arthroplasty 14 1999 9 20
-
(1999)
J. Arthroplasty
, vol.14
, pp. 9-20
-
-
Nilsson, K.G.1
Kärrholm, J.2
Carlsson, L.3
Dalen, T.4
-
28
-
-
0024950156
-
The knee society total knee arthroplasty roentgenographic evaluation and scoring system
-
F.C. Ewald The knee society total knee arthroplasty roentgenographic evaluation and scoring system Clin. Orthop. 248 1989 9 12
-
(1989)
Clin. Orthop.
, vol.248
, pp. 9-12
-
-
Ewald, F.C.1
-
29
-
-
2342582169
-
Comparison of various vacuum mixing systems and bone cements as regards reliability, porosity, and bending strength
-
H. Mau, K. Schelling, C. Heisel, J.S. Wang, and S.J. Breusch Comparison of various vacuum mixing systems and bone cements as regards reliability, porosity, and bending strength Acta Orthop. Scand. 75 2004 160 172
-
(2004)
Acta Orthop. Scand.
, vol.75
, pp. 160-172
-
-
Mau, H.1
Schelling, K.2
Heisel, C.3
Wang, J.S.4
Breusch, S.J.5
-
31
-
-
0036933938
-
New PMMA bone cements for vacuum mixing systems
-
K. Schelling, C. Heisel, S.M. Schnurer, H. Mau, and S.J. Breusch New PMMA bone cements for vacuum mixing systems Orthapade 31 2002 556 562
-
(2002)
Orthapade
, vol.31
, pp. 556-562
-
-
Schelling, K.1
Heisel, C.2
Schnurer, S.M.3
Mau, H.4
Breusch, S.J.5
-
32
-
-
0003834105
-
-
Thesis (PhD), University of Gothenburg, Gothenburg, Sweden
-
Malchau, H. On the importance of stepwise introduction of new hip implant technology. Assessment of total hip replacement using clinical evaluation, radiostereometry, digitized radiography, and a national hip registry. Thesis (PhD), University of Gothenburg, Gothenburg, Sweden (1995).
-
(1995)
On the Importance of Stepwise Introduction of New Hip Implant Technology. Assessment of Total Hip Replacement Using Clinical Evaluation, Radiostereometry, Digitized Radiography, and a National Hip Registry
-
-
Malchau, H.1
|